Hang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hang Wang has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
- Cheng Zhang
Beijing International S&T Cooperation Base for Plasma Science and Energy Conversion, Institute of Electrical Engineering, Chinese Academy of Sciences
4 shared publications - Tao Shao
State Key Laboratory of Power Grid Environmental Protection School of Electrical Engineering and Automation Wuhan University Wuhan China
4 shared publications Bin Yang
State Grid Wuhan Electric Power Supply Company, Wuhan, China
3 shared publications- Hang Li
Wuhan Power Supply Company, State Grid Hubei Electric Power Company, Wuhan 430013
3 shared publications Jing Tu
State Grid Wuhan Electric Power Supply Company, Wuhan, China
3 shared publications- Jing Tu
Electrical Cable Operation and Maintenance Branch of Wuhan Power Supply Company, Hubei Power Supply Company, State Grid, Wuhan 430024, China
3 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 11 (5) , 1524-1582
Large‐Scale Applications of Plasma Technologies: Progresses and Challenges
Plasma technologies convert electrical power into energetic electrons, ions, reactive species, radiation and heat, thereby breaking through the bottleneck of purely thermal or chemical routes and bringing impressive changes to our world. This roadmap reviews the progress and challenges of plasma technologies from a large‐scale and application‐driven perspective. It covers plasma–material interaction (i.e., surface modification, material preparation and semiconductor processing), aerospace applications (i.e., plasma propulsion, plasma‐assisted aerodynamics, plasma‐assisted ignition and combustion), applications in the energy field (i.e., industrial arc discharge, plasma catalysis for decarbonisation including CO 2 conversion, nitrogen fixation and hydrogen‐related processes, and plasma‐enabled resource recovery) and applications related to human health (i.e., biomedicine, plasma disinfection/sterilisation, agriculture and food). We also present a unified cross‐comparison of mainstream plasma sources and practical selection guidelines. Beyond reviewing these advances, this roadmap argues that the large‐scale deployment of plasma technologies will be governed by four constraints: controllability of plasma parameters and discharge modes during scale‐up, system‐level energy efficiency from grid to outcome, long‐term reliability and maintainability in realistic environments, and outcome‐relevant diagnostics and harmonised benchmarking. The authors hope this roadmap will enrich the track record and enable cutting‐edge advances in plasma technologies over the next 5–10 years.
- 30 September 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 11 (5) , 1524-1582
Open AccessLarge‐Scale Applications of Plasma Technologies: Progresses and Challenges
Plasma technologies convert electrical power into energetic electrons, ions, reactive species, radiation and heat, thereby breaking through the bottleneck of purely thermal or chemical routes and bringing impressive changes to our world. This roadmap reviews the progress and challenges of plasma technologies from a large‐scale and application‐driven perspective. It covers plasma–material interaction (i.e., surface modification, material preparation and semiconductor processing), aerospace applications (i.e., plasma propulsion, plasma‐assisted aerodynamics, plasma‐assisted ignition and combustion), applications in the energy field (i.e., industrial arc discharge, plasma catalysis for decarbonisation including CO 2 conversion, nitrogen fixation and hydrogen‐related processes, and plasma‐enabled resource recovery) and applications related to human health (i.e., biomedicine, plasma disinfection/sterilisation, agriculture and food). We also present a unified cross‐comparison of mainstream plasma sources and practical selection guidelines. Beyond reviewing these advances, this roadmap argues that the large‐scale deployment of plasma technologies will be governed by four constraints: controllability of plasma parameters and discharge modes during scale‐up, system‐level energy efficiency from grid to outcome, long‐term reliability and maintainability in realistic environments, and outcome‐relevant diagnostics and harmonised benchmarking. The authors hope this roadmap will enrich the track record and enable cutting‐edge advances in plasma technologies over the next 5–10 years.
- Open Access
Sheath-to-Ground Fault Impedance Calculation and Localization Method in Cross-Bonded High-Voltage Cable Systems
Abnormal circulating current induced by sheath grounding faults in cross-bonded high-voltage cables is a major cause of single-phase grounding faults. For the early detection and localization of sheath grounding faults, this paper constructs an equivalent circuit model for three-phase nine-section cross-bonded cables. Circuit model parameters are estimated via online monitoring data. The relational equation between sheath electrical quantities, fault impedance, and distance is derived for typical sheath grounding faults. Using the Adam algorithm, the solution of fault impedance and location is converted into the minimization of an optimization objective function. Simulation results show that under the influences of phase current imbalance, measurement error, and fault impedance fluctuation, the Adam algorithm exhibits superior optimization accuracy and computational efficiency in comparison with the ED and GA algorithms. Experimental results show that for low-resistance sheath grounding, the proposed method has a fault impedance calculation error ≤ 0.59% and a fault positioning error ≤ 1.89%. For metallic sheath grounding with zero resistance, the positioning error is ≤1.37%. Field test results demonstrate that the proposed method performs similarly to the time-domain reflectometry method, with a positioning deviation ≤ 0.15 m, and can meet online monitoring requirements.
Open AccessSheath-to-Ground Fault Impedance Calculation and Localization Method in Cross-Bonded High-Voltage Cable Systems
Abnormal circulating current induced by sheath grounding faults in cross-bonded high-voltage cables is a major cause of single-phase grounding faults. For the early detection and localization of sheath grounding faults, this paper constructs an equivalent circuit model for three-phase nine-section cross-bonded cables. Circuit model parameters are estimated via online monitoring data. The relational equation between sheath electrical quantities, fault impedance, and distance is derived for typical sheath grounding faults. Using the Adam algorithm, the solution of fault impedance and location is converted into the minimization of an optimization objective function. Simulation results show that under the influences of phase current imbalance, measurement error, and fault impedance fluctuation, the Adam algorithm exhibits superior optimization accuracy and computational efficiency in comparison with the ED and GA algorithms. Experimental results show that for low-resistance sheath grounding, the proposed method has a fault impedance calculation error ≤ 0.59% and a fault positioning error ≤ 1.89%. For metallic sheath grounding with zero resistance, the positioning error is ≤1.37%. Field test results demonstrate that the proposed method performs similarly to the time-domain reflectometry method, with a positioning deviation ≤ 0.15 m, and can meet online monitoring requirements.
- Open Access
Cross-Bonded Cable Circuits Identification Based on Deep Embedded Clustering of Sheath Current Sensing
Online identification of HV cable circuits is vital for routine inspection and maintenance, yet existing passive electromagnetic wave injection methods are limited to offline operations. To fill the gap and achieve the online identification of HV cable circuits, an online circuit identification methodology based on sheath current temporal characteristics and deep embedded clustering is proposed. First, an equivalent circuit model of the multi-circuit cross-bonded cable sheath was built to deduce the temporal similarity of sheath currents within the same circuit, establishing the identification criterion. Second, the robustness of the temporal similarity under various operating conditions was verified via simulation based on the Dynamic Time Warping (DTW) distance. Then, a combined model of Temporal Convolutional Network Autoencoder (TCN-AE) and K-medoids was established to transform circuit identification into a temporal clustering problem of sheath currents, realizing circuit determination by synchronously monitoring the time-series sheath current data of multi-circuit HV cross-bonded cables. The method was verified on a full-scale 110 kV cable test platform. The results show that the identification accuracy reached 95.37%, and the proposed method can effectively identify the circuits of cross-bonded cables with high robustness against the domain gap, having significant engineering application value.
Open AccessCross-Bonded Cable Circuits Identification Based on Deep Embedded Clustering of Sheath Current Sensing
Online identification of HV cable circuits is vital for routine inspection and maintenance, yet existing passive electromagnetic wave injection methods are limited to offline operations. To fill the gap and achieve the online identification of HV cable circuits, an online circuit identification methodology based on sheath current temporal characteristics and deep embedded clustering is proposed. First, an equivalent circuit model of the multi-circuit cross-bonded cable sheath was built to deduce the temporal similarity of sheath currents within the same circuit, establishing the identification criterion. Second, the robustness of the temporal similarity under various operating conditions was verified via simulation based on the Dynamic Time Warping (DTW) distance. Then, a combined model of Temporal Convolutional Network Autoencoder (TCN-AE) and K-medoids was established to transform circuit identification into a temporal clustering problem of sheath currents, realizing circuit determination by synchronously monitoring the time-series sheath current data of multi-circuit HV cross-bonded cables. The method was verified on a full-scale 110 kV cable test platform. The results show that the identification accuracy reached 95.37%, and the proposed method can effectively identify the circuits of cross-bonded cables with high robustness against the domain gap, having significant engineering application value.
- Open Access
Phase Selection Method for 10 kV Three-Core Cables Under Single-Phase Grounding Fault Transient Based on Surface Magnetic Field Sensing
Single-phase grounding is the dominant fault type in urban power distribution networks. Because the total magnetic flux would not change around the cable under a single-phase grounding fault, ferromagnetic zero-sequence current sensors cannot distinguish the faulted phase of belted cables, which are the main type in 10 kV distribution networks. To fill this gap, a two-step methodology is proposed using an annular TMR magnetic sensor to measure the magnetic field intensity at six points on the cable surface and to distinguish the faulted phase using the magnetic field intensity differences between the TMRs. The first step is calculating the rotation angles between the six magnetic sensors and the three cable cores after installation. A differential evolution algorithm is used to calculate the rotation angles in the sensing model. The second step is to detect the fault phase under a single-phase grounding fault transient, with the magnetic field intensity difference taken as the criterion. The methodology is verified through simulation and experiment. The results show that the relative errors of the rotation angles are all less than 1%. Under a single-phase grounding fault, the faulted phase can be accurately identified. The proposed method can effectively identify the faulted phase of 10 kV three-core cables under single-phase grounding and has significant engineering application value.
Open AccessPhase Selection Method for 10 kV Three-Core Cables Under Single-Phase Grounding Fault Transient Based on Surface Magnetic Field Sensing
Single-phase grounding is the dominant fault type in urban power distribution networks. Because the total magnetic flux would not change around the cable under a single-phase grounding fault, ferromagnetic zero-sequence current sensors cannot distinguish the faulted phase of belted cables, which are the main type in 10 kV distribution networks. To fill this gap, a two-step methodology is proposed using an annular TMR magnetic sensor to measure the magnetic field intensity at six points on the cable surface and to distinguish the faulted phase using the magnetic field intensity differences between the TMRs. The first step is calculating the rotation angles between the six magnetic sensors and the three cable cores after installation. A differential evolution algorithm is used to calculate the rotation angles in the sensing model. The second step is to detect the fault phase under a single-phase grounding fault transient, with the magnetic field intensity difference taken as the criterion. The methodology is verified through simulation and experiment. The results show that the relative errors of the rotation angles are all less than 1%. Under a single-phase grounding fault, the faulted phase can be accurately identified. The proposed method can effectively identify the faulted phase of 10 kV three-core cables under single-phase grounding and has significant engineering application value.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 154279-154290
Single-Phase Grounding Fault Pre-Location for 10-kV Three-Core Cables in Power Distribution Networks Based on Traveling Waves of Two-Terminal Surface Magnetic Fields
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 154279-154290
Open AccessSingle-Phase Grounding Fault Pre-Location for 10-kV Three-Core Cables in Power Distribution Networks Based on Traveling Waves of Two-Terminal Surface Magnetic Fields
- Open Access
- 9 December 2025
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 10 (6) , 1380-1389
Partial Discharge Detection Method of Fibre‐Composed HVDC Submarine Cable Based on φ ‐OTDR and Hilbert Demodulation
Partial discharge (PD) is the indicator of the insulation defect in cables. However, the pulse current method, which is widely adopted in land cables, cannot obtain PD signals of high‐voltage direct current (HVDC) submarine cables due to attenuation and installation position. To detect the PD of the HVDC submarine cable, a PD vibration diagnosis methodology using the embedded fibre based on the heterodyne interferometric phase‐sensitive optical time‐domain reflectometry ( φ ‐OTDR) and Hilbert demodulation is proposed. The proposed method is verified by a PD experiment with preset defects in 220 kV submarine cables under DC voltage. The results show that the PD can be detected by fibre using the proposed method. Among the three types of PD generated in preset defects in 220 kV submarine cables under DC voltage, the inception voltage of corona discharge, internal airgap discharge and surface discharge is 18, 14 and 14 kV, respectively. The peak value of the phase difference in corona discharge is the smallest, and the peak value of the phase difference in surface discharge is close to that in internal airgap discharge. A recommended parameter configuration is provided through statistical analysis, where a modulation frequency of 10 kHz and a pulse width of 100 ns achieve a 10% detection probability at 2.25 km fibre length and 10 m spatial resolution.
- 9 December 2025
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 10 (6) , 1380-1389
Open AccessPartial Discharge Detection Method of Fibre‐Composed HVDC Submarine Cable Based on φ ‐OTDR and Hilbert Demodulation
Partial discharge (PD) is the indicator of the insulation defect in cables. However, the pulse current method, which is widely adopted in land cables, cannot obtain PD signals of high‐voltage direct current (HVDC) submarine cables due to attenuation and installation position. To detect the PD of the HVDC submarine cable, a PD vibration diagnosis methodology using the embedded fibre based on the heterodyne interferometric phase‐sensitive optical time‐domain reflectometry ( φ ‐OTDR) and Hilbert demodulation is proposed. The proposed method is verified by a PD experiment with preset defects in 220 kV submarine cables under DC voltage. The results show that the PD can be detected by fibre using the proposed method. Among the three types of PD generated in preset defects in 220 kV submarine cables under DC voltage, the inception voltage of corona discharge, internal airgap discharge and surface discharge is 18, 14 and 14 kV, respectively. The peak value of the phase difference in corona discharge is the smallest, and the peak value of the phase difference in surface discharge is close to that in internal airgap discharge. A recommended parameter configuration is provided through statistical analysis, where a modulation frequency of 10 kHz and a pulse width of 100 ns achieve a 10% detection probability at 2.25 km fibre length and 10 m spatial resolution.
- Open Access
Seasonal Load Statistics of EV Charging and Battery Swapping Stations Based on Gaussian Mixture Model for Charging Strategy Optimization in Electric Power Distribution Systems
The rapidly growing demand of electric vehicle (EV) charging is one of the main challenges to modern electrical distribution systems. Accurate modelling of the EV charging load is crucial for charging load prediction and optimization. However, previous methods based on the charging behaviors of private EVs are hard to collect user’s private data. In this study, charging load data from 962 charging and battery swapping stations (CBSSs), classified into dedicated charging stations, public charging stations, and battery swapping stations, collected during 2021–2022, are analyzed to investigate seasonal variations in the charging coincidence factor. A data-driven probabilistic model of charging load, based on the Gaussian Mixture Model, is developed to address various scenarios, including new station construction, capacity expansions, and optimized charging strategies. This model is applicable to different types of CBSSs. A real-world 10 kV feeder system is employed as a case study to validate the model, and a delayed charging strategy is proposed. The results demonstrate that the proposed model accurately estimates charging load peaks after new construction and expansion in 2023, with an error rate under 3%. Furthermore, the delayed charging strategy achieved a 24.79% reduction in maximum load and a 31.96% decrease in the peak–valley difference. Its implementation in the real-world feeder significantly alleviated nighttime overloading in 2024.
Open AccessSeasonal Load Statistics of EV Charging and Battery Swapping Stations Based on Gaussian Mixture Model for Charging Strategy Optimization in Electric Power Distribution Systems
The rapidly growing demand of electric vehicle (EV) charging is one of the main challenges to modern electrical distribution systems. Accurate modelling of the EV charging load is crucial for charging load prediction and optimization. However, previous methods based on the charging behaviors of private EVs are hard to collect user’s private data. In this study, charging load data from 962 charging and battery swapping stations (CBSSs), classified into dedicated charging stations, public charging stations, and battery swapping stations, collected during 2021–2022, are analyzed to investigate seasonal variations in the charging coincidence factor. A data-driven probabilistic model of charging load, based on the Gaussian Mixture Model, is developed to address various scenarios, including new station construction, capacity expansions, and optimized charging strategies. This model is applicable to different types of CBSSs. A real-world 10 kV feeder system is employed as a case study to validate the model, and a delayed charging strategy is proposed. The results demonstrate that the proposed model accurately estimates charging load peaks after new construction and expansion in 2023, with an error rate under 3%. Furthermore, the delayed charging strategy achieved a 24.79% reduction in maximum load and a 31.96% decrease in the peak–valley difference. Its implementation in the real-world feeder significantly alleviated nighttime overloading in 2024.
- Open Access
Two-Sheath Loop Short Circuit Defects Detection in High-Voltage Cable Systems Using Sheath Current Phasors
The joint is the weak point of HV (high voltage) cable insulation systems; creep discharge between insulation layers of the cable joint, due to moisture intrusion, is one of the main defects leading to single-phase grounding. Carbonization on the insulation interface after creep discharge would lead to a short-circuit defect in the sheath loops and result in abnormal sheath current. In this study, a novel diagnostic criterion using the phasor difference of sheath currents at both ends of the same circuit is proposed. The coupling effect between the sheath and the conductor under defect conditions is considered, and the original lumped parameter model of the cable circuit is optimized. The cable parameters are further corrected using a genetic algorithm. The diagnostic criterion comprehensively accounts for the adverse effects of unequal cable segment lengths, load current fluctuations, grounding impedance, and phase voltage variations. When the phase angle fluctuation of the phasor difference is within 10° and the defect impedance is below 100 Ω, the defective joint can be accurately diagnosed by this method. The conclusion has been validated through PSCAD simulations, with a diagnostic accuracy above 97%. Even under 20 dB noise interference, the error increase remains within 2%.
Open AccessTwo-Sheath Loop Short Circuit Defects Detection in High-Voltage Cable Systems Using Sheath Current Phasors
The joint is the weak point of HV (high voltage) cable insulation systems; creep discharge between insulation layers of the cable joint, due to moisture intrusion, is one of the main defects leading to single-phase grounding. Carbonization on the insulation interface after creep discharge would lead to a short-circuit defect in the sheath loops and result in abnormal sheath current. In this study, a novel diagnostic criterion using the phasor difference of sheath currents at both ends of the same circuit is proposed. The coupling effect between the sheath and the conductor under defect conditions is considered, and the original lumped parameter model of the cable circuit is optimized. The cable parameters are further corrected using a genetic algorithm. The diagnostic criterion comprehensively accounts for the adverse effects of unequal cable segment lengths, load current fluctuations, grounding impedance, and phase voltage variations. When the phase angle fluctuation of the phasor difference is within 10° and the defect impedance is below 100 Ω, the defective joint can be accurately diagnosed by this method. The conclusion has been validated through PSCAD simulations, with a diagnostic accuracy above 97%. Even under 20 dB noise interference, the error increase remains within 2%.
- Open Access
- 15 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 125970-125981
Sheath Voltage Limiter Defects Detection Method Based on Harmonic Phasor Differences of Sheath Current for Cross-Bonded HV Cable
The sheath voltage limiter (SVL) defect is a typical defect in HV cable cross-bonding systems that threatens cable system safety. Traditional surge arrester detection and time-domain sheath current analysis methods fail to accurately identify SVL defects due to environmental complexities and parameter variations. This paper proposes a defect diagnosis method based on harmonic phasor difference of sheath currents. By establishing a frequency-domain equivalent model of cross-bonded HV cables combined with SVL nonlinear resistance characteristics, harmonic currents under defect conditions are treated as harmonic sources injected into the sheath loop. Transfer functions analyze the impacts of SVL defects on sheath currents, revealing that harmonic content during SVL defects is significantly higher than under normal conditions and other defect types. Through simulation analysis using 110kV cable as the case study, diagnostic criteria based on harmonic content of sheath current phasor differences were established: When SVL defects occur in sheath loop 1, the 3rd, 5th, 7th, and 9th harmonic content variation ranges of the head-to-tail sheath current phasor difference in this loop are 1.88%~21.31%, 0.79%~8.98%, 0.17%~1.94%, and 0.11%~1.10% respectively; When SVL defects occur in sheath loop 2, the 3rd, 5th, 7th, and 9th harmonic content variation ranges of the head-to-tail sheath current phasor difference in this loop are 1.30%~23.71%, 0.55%~9.99%, 0.12%~2.16%, and 0.07%~1.22% respectively; When SVL defects occur in sheath loop 3, the 3rd, 5th, 7th, and 9th harmonic content variation ranges of the head-to-tail sheath current phasor difference in this loop are 1.53%~16.15%, 0.65%~6.81%, 0.14%~1.47%, and 0.08%~0.83% respectively. The harmonic content of phasor differences is significantly affected by ground impedance and phase currents, while the influence of phase voltage is insignificant. Compared with existing methods, this approach takes into account the effects of complex environmental factors and effectively resolves the issue of traditional diagnostic methods being unable to distinguish between SVL defects and other types of grounding defects, thereby improving the accuracy of SVL defect diagnosis.
- 15 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 125970-125981
Open AccessSheath Voltage Limiter Defects Detection Method Based on Harmonic Phasor Differences of Sheath Current for Cross-Bonded HV Cable
The sheath voltage limiter (SVL) defect is a typical defect in HV cable cross-bonding systems that threatens cable system safety. Traditional surge arrester detection and time-domain sheath current analysis methods fail to accurately identify SVL defects due to environmental complexities and parameter variations. This paper proposes a defect diagnosis method based on harmonic phasor difference of sheath currents. By establishing a frequency-domain equivalent model of cross-bonded HV cables combined with SVL nonlinear resistance characteristics, harmonic currents under defect conditions are treated as harmonic sources injected into the sheath loop. Transfer functions analyze the impacts of SVL defects on sheath currents, revealing that harmonic content during SVL defects is significantly higher than under normal conditions and other defect types. Through simulation analysis using 110kV cable as the case study, diagnostic criteria based on harmonic content of sheath current phasor differences were established: When SVL defects occur in sheath loop 1, the 3rd, 5th, 7th, and 9th harmonic content variation ranges of the head-to-tail sheath current phasor difference in this loop are 1.88%~21.31%, 0.79%~8.98%, 0.17%~1.94%, and 0.11%~1.10% respectively; When SVL defects occur in sheath loop 2, the 3rd, 5th, 7th, and 9th harmonic content variation ranges of the head-to-tail sheath current phasor difference in this loop are 1.30%~23.71%, 0.55%~9.99%, 0.12%~2.16%, and 0.07%~1.22% respectively; When SVL defects occur in sheath loop 3, the 3rd, 5th, 7th, and 9th harmonic content variation ranges of the head-to-tail sheath current phasor difference in this loop are 1.53%~16.15%, 0.65%~6.81%, 0.14%~1.47%, and 0.08%~0.83% respectively. The harmonic content of phasor differences is significantly affected by ground impedance and phase currents, while the influence of phase voltage is insignificant. Compared with existing methods, this approach takes into account the effects of complex environmental factors and effectively resolves the issue of traditional diagnostic methods being unable to distinguish between SVL defects and other types of grounding defects, thereby improving the accuracy of SVL defect diagnosis.
- Open Access
- 6 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 82467-82478
CNN-Based Detection of Sheath Incorrect Connection in the Cross-Bonded HV Cable Systems Using the Sheath Current Phasor Difference
Incorrect connection of metallic sheath is a typical defect in long HV(High-Voltage) cross-boned cable systems. However, the previous detection methods based on sheath current rely on three criteria: the amplitude of the sheath current, the ratio of the sheath current to the load current, and the relative values of the sheath current across the three sheath loops. These criteria, however, are insufficient for accurately identifying the defect. In this paper, a CNN (Convolutional Neural Network) based methodology using the sheath current phasor difference at both ends of the same sheath loop is proposed to distinguish the 34 types of incorrect connection with 2 types of correct connection. Taking an 110 kV cable as the simulation case, the results show that the sheath current phasor difference is significantly affected by the unequal lengths of the three small segments of the cable. Besides, the sheath current phasor difference at both ends of the same loop can not only distinguish the correct and incorrect connection states of cross-bonded high-voltage cable sheaths but also differentiate different connection error modes. The classification model for high-voltage cable cross-bonding errors based on CNN can effectively recognize 36 different cross-bonding configurations of high-voltage cables, with a model accuracy of over 98%. Through comparison with other algorithms, it is found that the CNN exhibits the best performance in identifying various cross-bonding error scenarios.
- 6 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 82467-82478
Open AccessCNN-Based Detection of Sheath Incorrect Connection in the Cross-Bonded HV Cable Systems Using the Sheath Current Phasor Difference
Incorrect connection of metallic sheath is a typical defect in long HV(High-Voltage) cross-boned cable systems. However, the previous detection methods based on sheath current rely on three criteria: the amplitude of the sheath current, the ratio of the sheath current to the load current, and the relative values of the sheath current across the three sheath loops. These criteria, however, are insufficient for accurately identifying the defect. In this paper, a CNN (Convolutional Neural Network) based methodology using the sheath current phasor difference at both ends of the same sheath loop is proposed to distinguish the 34 types of incorrect connection with 2 types of correct connection. Taking an 110 kV cable as the simulation case, the results show that the sheath current phasor difference is significantly affected by the unequal lengths of the three small segments of the cable. Besides, the sheath current phasor difference at both ends of the same loop can not only distinguish the correct and incorrect connection states of cross-bonded high-voltage cable sheaths but also differentiate different connection error modes. The classification model for high-voltage cable cross-bonding errors based on CNN can effectively recognize 36 different cross-bonding configurations of high-voltage cables, with a model accuracy of over 98%. Through comparison with other algorithms, it is found that the CNN exhibits the best performance in identifying various cross-bonding error scenarios.