Apoorva Kaul
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Apoorva Kaul has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Gopika C. T.
Nanomaterials Research Laboratory, Surface Engineering Division, CSIR - National Aerospace Laboratories, Bangalore 560 017, India
7 shared publications Bhagaban Behera
4 shared publicationsJakeer Khan
Nanomaterials Research Laboratory, Surface Engineering Division, CSIR - National Aerospace Laboratories, Bangalore 560 017, India
4 shared publicationsP. Chowdhury
3 shared publications- Prasanta Chowdhury
Nanomaterials Research Laboratory, Surface Engineering Division, CSIR - National Aerospace Laboratories, Bangalore 560 017, India
3 shared publications - Bhagaban Behera
Nanomaterials Research Laboratory, Surface Engineering Division, CSIR—National Aerospace Laboratories 1 , Bangalore 560 017
2 shared publications
Latest Publications
- 14 October 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 412
Highly reversible nano-tesla MTJ sensor using composite Ta/NiFe sensing-layer engineering
- 14 October 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 412
Highly reversible nano-tesla MTJ sensor using composite Ta/NiFe sensing-layer engineering
- 1 September 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (9) , 095960
Reversible linear transfer curves of MTJ-based magnetic sensor with AC/DC longitudinal biasing
Magnetoresistance (MR) devices are helpful for various magnetic sensor applications, especially for ultra-sensitive magnetic field detection. In this study, we report on tunnel magnetoresistance sensors with two CoFeB ferromagnetic electrodes on both sides of a MgO tunnel barrier, with a higher MR ratio of ≈180%. The transfer curve of the sensors with push-pull Wheatstone bridge configuration reported a bipolar transfer curve with an average sensitivity of 103.5 ± 2 mV/V/Oe near H C and hysteresis of 8 Oe. However, with the application of longitudinal biasing (LB) under an externally applied AC/DC biasing field, the reversible transfer curves were observed above a critical LB field. The critical LB field for AC was around 23 Oe, and the measured sensitivity was 47 mV/V/Oe with field detectivity of approximately ±400 nT @ 1 Hz, whereas for the DC case, these values were 35 Oe, 25 mV/V/Oe, and ± 25 nT @ 1 Hz, respectively.
- 1 September 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (9) , 095960
Reversible linear transfer curves of MTJ-based magnetic sensor with AC/DC longitudinal biasing
Magnetoresistance (MR) devices are helpful for various magnetic sensor applications, especially for ultra-sensitive magnetic field detection. In this study, we report on tunnel magnetoresistance sensors with two CoFeB ferromagnetic electrodes on both sides of a MgO tunnel barrier, with a higher MR ratio of ≈180%. The transfer curve of the sensors with push-pull Wheatstone bridge configuration reported a bipolar transfer curve with an average sensitivity of 103.5 ± 2 mV/V/Oe near H C and hysteresis of 8 Oe. However, with the application of longitudinal biasing (LB) under an externally applied AC/DC biasing field, the reversible transfer curves were observed above a critical LB field. The critical LB field for AC was around 23 Oe, and the measured sensitivity was 47 mV/V/Oe with field detectivity of approximately ±400 nT @ 1 Hz, whereas for the DC case, these values were 35 Oe, 25 mV/V/Oe, and ± 25 nT @ 1 Hz, respectively.
- Open Access
- 12 August 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (6)
Ultra-soft magnetic properties in Ta/NiFe laminated system
An integrated magnetic flux concentrator (MFC) has become a choice for enhancing the sensitivity of a magnetic field sensor. However, the flux concentrator’s geometry and its ultra-soft magnetic properties are the key ingredients for successful implementation to improve the detectability of a magnetic sensor. In this report, the laminated stack of Ta/Ru/[NiFe(tNiFe)/Ta(tTa)]N/Ta of thickness 0.5 μm was investigated, where tNiFe, tTa, and N were varied to optimize ultra-soft magnetic properties of the film and compared them with the bulk NiFe film. Structural investigations revealed that incorporating an ultra-thin layer of Ta in the laminated stack suppresses the grain growth of the NiFe phase and improves the textured growth of the fcc(111) phase of the NiFe alloy. This results in dramatic improvement of the measured magnetic hysteresis loop of the laminated stack with a reduced coercivity field in the range of 0.4 ± 0.1 Oe, high linearity, and low saturation field (<10 Oe) while comparing them with the bulk film of NiFe of equivalent thicknesses. The laminated stack thickness of up to 4 μm was further investigated, and the bilinear M(H) loop was explained through antiferromagnetic (AFM) interlayer coupling between successive NiFe layers.
- 12 August 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (6)
Open AccessUltra-soft magnetic properties in Ta/NiFe laminated system
An integrated magnetic flux concentrator (MFC) has become a choice for enhancing the sensitivity of a magnetic field sensor. However, the flux concentrator’s geometry and its ultra-soft magnetic properties are the key ingredients for successful implementation to improve the detectability of a magnetic sensor. In this report, the laminated stack of Ta/Ru/[NiFe(tNiFe)/Ta(tTa)]N/Ta of thickness 0.5 μm was investigated, where tNiFe, tTa, and N were varied to optimize ultra-soft magnetic properties of the film and compared them with the bulk NiFe film. Structural investigations revealed that incorporating an ultra-thin layer of Ta in the laminated stack suppresses the grain growth of the NiFe phase and improves the textured growth of the fcc(111) phase of the NiFe alloy. This results in dramatic improvement of the measured magnetic hysteresis loop of the laminated stack with a reduced coercivity field in the range of 0.4 ± 0.1 Oe, high linearity, and low saturation field (<10 Oe) while comparing them with the bulk film of NiFe of equivalent thicknesses. The laminated stack thickness of up to 4 μm was further investigated, and the bilinear M(H) loop was explained through antiferromagnetic (AFM) interlayer coupling between successive NiFe layers.
- 24 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (4) , 1-6
Spin Valve Sensor With Integrated On-Chip Longitudinal Permanent Magnet Biasing for Linear Sensing Applications
This study focuses on fabricating spin-valve Giant Magnetoresistance (SV-GMR) sensors integrated with longitudinal permanent magnet (PM) biasing, resulting in a linearized field response with reduced hysteresis. For this, CoCrPt thick films were sputter-deposited under optimized conditions to achieve the highest Hc value of the order of 1600 Oe with a higher squareness ratio. Detailed Finite Element Method (FEM) confirmed the biasing field less than 40 Oe can be produced by PM with a thickness of 1 μm across the sensing elements with a gap of 90 μm. The SV-GMR sensors are patterned into resistors of on-chip push-pull Wheatstone bridge assembly and biased with PM to reduce coercivity with improved linearity. Furthermore, the device’s performance was evaluated across a broader temperature spectrum, revealing notable thermal stability within -40°C to 125°C. These findings highlight the sensor’s reliability and precision linear field sensing applications, specifically for low current measurements.
- 24 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (4) , 1-6
Spin Valve Sensor With Integrated On-Chip Longitudinal Permanent Magnet Biasing for Linear Sensing Applications
This study focuses on fabricating spin-valve Giant Magnetoresistance (SV-GMR) sensors integrated with longitudinal permanent magnet (PM) biasing, resulting in a linearized field response with reduced hysteresis. For this, CoCrPt thick films were sputter-deposited under optimized conditions to achieve the highest Hc value of the order of 1600 Oe with a higher squareness ratio. Detailed Finite Element Method (FEM) confirmed the biasing field less than 40 Oe can be produced by PM with a thickness of 1 μm across the sensing elements with a gap of 90 μm. The SV-GMR sensors are patterned into resistors of on-chip push-pull Wheatstone bridge assembly and biased with PM to reduce coercivity with improved linearity. Furthermore, the device’s performance was evaluated across a broader temperature spectrum, revealing notable thermal stability within -40°C to 125°C. These findings highlight the sensor’s reliability and precision linear field sensing applications, specifically for low current measurements.
- 28 January 2025
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 616
Enhancement of spin valve GMR sensor’s sensitivity with [Ta/NiFe] n on-chip magnetic flux concentrator
- 28 January 2025
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 616
Enhancement of spin valve GMR sensor’s sensitivity with [Ta/NiFe] n on-chip magnetic flux concentrator