YZYuqi Zhang

Yuqi Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuqi Zhang has a total of 49 co-authors. Here are the top co-authors by number of shared publications:

  • Changzhao Chen

    Department of Ultrasound Medicine, Hainan Women and Children'S Medical Center, Haikou, China

    2 shared publications
  • Lijun Chen

    Department of Pediatric Cardiology, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China

    2 shared publications
  • Tongtong Liang

    Shanghai Minhang District Center for Disease Control and Prevention, Shanghai Minhang District Health Supervision Institute, Shanghai, China

    2 shared publications
  • Yiman Liu

    Department of Pediatric Cardiology, Shanghai Children's Medical Center Shanghai Jiao Tong University School of Medicine Shanghai China

    2 shared publications
  • Yiman Liu

    Department of Pediatric Cardiology, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China

    2 shared publications
  • Aiqing Wang

    Department of Pediatric Cardiology, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China

    1 shared publication

Latest Publications

  • Cross-Center Online Generalization Algorithm with Unadversarial Consistency for Fetal Heart Ultrasound View Recognition

    by Yiman Liu, Tongtong Liang, Jiahe Tian, Nan Jiang, Changzhao Chen, Yuqi Zhang, Zhifang Zhang

    Fetal congenital heart disease (FCHD) remains a leading cause of infant mortality globally, yet the clinical deployment of deep learning models for automated fetal echocardiographic view recognition faces performance degradation due to domain shifts across medical centers. This study aims to develop a cross-center online adaptation framework to enhance model generalization in heterogeneous clinical environments without requiring target-domain labels. We propose a novel framework integrating three core components: (1) a dual-branch architecture with unadversarial perturbation-based consistency regularization to enforce feature invariance, (2) uncertainty-aware loss weighting via evidential deep learning (EDL) to prioritize high-uncertainty samples, and (3) selective fine-tuning of Batch Normalization (BN) layers to adapt domain-sensitive parameters efficiently. The framework dynamically adjusts model parameters during inference using unlabeled test data, avoiding costly retraining. Evaluated on multicenter fetal echocardiography datasets, the framework improved mean recognition accuracy by 0.88-2.55% across six deep learning models. DenseNet achieved the highest external test accuracy of 82.29%, outperforming baseline models. Feature visualization via t-SNE and heatmaps confirmed enhanced discriminative capability, while confusion matrices revealed reduced misclassification rates for challenging views (e.g., RVOT vs. 3VV/3VT). This work establishes a label-free adaptation strategy to address domain shifts in fetal ultrasound, demonstrating robust generalization across diverse clinical settings. By bridging AI innovation with practical deployment requirements, the framework offers a scalable solution to standardize prenatal screening quality, particularly benefiting resource-limited regions. Future efforts will extend validation to dynamic video analysis and broader multicenter datasets.

  • Open Access

    Echocardiography-based intelligent diagnosis and risk stratification management for tetralogy of Fallot

    by Qiang Gao, Aiqing Wang, Yingshuang Gao, Weichang Xie, Junyao Yang, Mei Yan, Shi Chao, Leisheng Zhao, Hui Lu, Yuqi Zhang, et al.


  • A Dual‐Center Study on Intelligent Detection of Ventricular Septal Defect in Pediatric Echocardiographic Videos Using the TSDNet Model

    by Yiman Liu, Lanping Wu, Tianze Wu, Zhifang Zhang, Lijun Chen, Wenjing Hong, Bin Dong, Jiajun Yuan, Hansong Wang, Zezhong Li, et al.

    This study aimed to develop an automated transthoracic echocardiography (TTE)‐based system for detecting ventricular septal defects (VSD) by jointly analyzing systolic‐phase temporal shunt dynamics and precisely localizing defect regions. This multicenter retrospective study analyzed transthoracic echocardiography videos from 324 pediatric patients (150 VSD ‐positive and 174 VSD ‐negative), supplemented by an external validation cohort of 60 cases. To address challenges inherent to dynamic cardiac hemodynamics and view‐dependent variability, we developed a Temporal–Spatial Decoupled Network ( TSDNet ). The methodological contributions of TSDNet are fourfold: (1) a temporal–spatial decoupling strategy that separates transient systolic shunt dynamics from static anatomical localization, overcoming the limitations of conventional spatiotemporal coupling; (2) a dual‐branch architecture that integrates a UniFormer ‐based temporal classifier with a YOLOv5 ‐based spatial detector to jointly perform video‐level diagnosis and frame‐level shunt localization; (3) multi‐view fusion across five standard echocardiographic views to capture complementary anatomical structures and hemodynamic signatures; and (4) a comprehensive evaluation framework encompassing accuracy, recall, specificity, F1 ‐score, PPV , and NPV , supplemented by experiments across multiple temporal window lengths and comparative analyses against state‐of‐the‐art object detection models. T SDNet demonstrated high performance in both video‐level classification and frame‐level VSD detection. Video‐level accuracy on the internal test set reached 96.19%, with external performance remaining consistently strong across varying temporal windows (87.37%–90.37% accuracy). For frame‐level detection, TSDNet achieved 86.86% accuracy on the internal test set and 73.75% on the external cohort, with longer temporal windows yielding progressively improved results. Across all evaluated metrics, TSDNet outperformed leading detection frameworks—including Sparse R‐ CNN , DINO , FCOS , RetinaNet , Faster R‐ CNN , and DCNv2 . Multi‐view analysis further confirmed stable detection performance, particularly in the A4C , PSAX , and subRVOT views, underscoring the effectiveness of combining diverse echocardiographic perspectives with temporal–spatial decoupling for robust VSD identification. T SDNet provides accurate, robust, and interpretable detection of VSD from pediatric echocardiography videos. Its strong generalizability and seamless alignment with clinical workflows underscore its potential to enhance diagnostic capability in primary healthcare settings and to support early identification of congenital heart disease.

  • Open Access

    Cardiovascular phenotypes of children and adolescents with Turner syndrome from a single-center cohort study

    by Feihan Hu, Yirou Wang, Yao Chen, Xueqiong Xu, Yu Ding, Lingwen Ying, Qianwen Zhang, Libo Wang, Yuqi Zhang, Lijun Chen, et al.

    Background: Approximately half of the patients with Turner syndrome (TS) have congenital or acquired cardiovascular diseases. The objectives of this study were to improve the early diagnosis of TS and to predict the risk of severe cardiovascular diseases in patients with TS by analyzing the main features of cardiovascular diseases in these patients. Methods: This study included 107 patients with TS who underwent echocardiography and were admitted to the Shanghai Children’s Medical Center between November 2019 and November 2024. In this study, the height, weight, age, karyotype, cardiac imaging data, and electrocardiograms of the patients were collected. The main features of the cardiovascular diseases in patients with TS were assessed, and the correlations between the height, body mass index (BMI), karyotype, and cardiovascular diseases were analyzed. Results: Overall, 107 patients with TS were included, with an average age of 9.68 ± 4.23 years at diagnosis. Bicuspid aortic valve (BAV), aortic coarctation (CoA), and persistent left superior vena cava (PLSVC) were the most prevalent cardiovascular diseases, with prevalence rates of 11.2% (12/107), 8.4% (9/107), and 9.3% (10/107), respectively. The partial anomalous pulmonary venous return (PAPVC) was of the ‘supra cardiac type’ in all cases. Patients with CoA had lower BMI-for-age Z-score (BMIAZ) (-0.81 ± 1.17 vs. 0.61 ± 0.99; P = 0.003) than those without CoA. The best cutoff for predicting CoA was calculated using a sensitivity of 0.857 and specificity of 0.697 with a BMIAZ of 0.115 and an area under the curve of 0.825 ( P = 0.004). Moreover, CoA (63.3%, 7/11) was the leading cause for surgical and interventional procedures in children and adolescents with TS. The 45,X karyotype was found to be associated with congenital heart disease (CHD) (47.4% vs. 24.6%; P = 0.016). Conclusions: Girls with BAV or CoA should undergo karyotyping to facilitate the early diagnosis of TS. CoA is the leading cause for surgical and interventional procedures in children and adolescents with TS. The BMIAZ is a reliable predictor of CoA. Cardiovascular magnetic resonance (CMR) or computed tomography (CT) should be performed at the time of diagnosis for girls with TS, especially those with a 45,X karyotype, BMIAZ < 0.115, or CHD detected by echocardiography.

  • An efficient network with state space model under evidential training for fetal echocardiography standard view recognition

    by Changzhao Chen, Yiman Liu, Tongtong Liang, Shibin Lin, Xiaoxiang Han, Xiaohong Liu, Jing Yang, Yuqi Zhang, Xueping Yan

    Fetal congenital heart disease (FCHD) represents a serious and prevalent congenital malformation. However, there exist notable regional disparities in the detection rates of fetal heart abnormalities. To enhance the diagnostic capabilities of ultrasound physicians in primary hospitals regarding fetal heart structures, the adoption of artificial intelligence technology to assist in acquiring high-quality, standard fetal echocardiographic images is of paramount importance. Currently, primary hospitals face challenges in recognizing standard views in fetal echocardiography, particularly under resource-constrained conditions. Efficient and accurate identification of fetal heart structures has become an urgent issue to address. Despite existing research efforts dedicated to the recognition of standard views in fetal echocardiography, current methods still suffer from limitations in computational complexity, feature extraction capabilities, and long-distance feature capturing, hindering their widespread application in ultrasound diagnosis at primary hospitals. Specifically, the literature lacks an efficient and robust model that can effectively balance high accuracy in standard view recognition with low computational complexity and fast inference times. The need for a model that can accurately capture long-distance features while maintaining efficiency is particularly acute in the context of primary hospitals, where resources are limited and the demand for accurate fetal heart assessments is high. To address these issues, the present study proposes an efficient network based on a state-space model trained with evidence for standard view recognition in fetal echocardiography. This method integrates a visual state space (VSS) model, which boasts powerful feature extraction capabilities and effective long-distance feature capturing, while significantly reducing computational complexity and facilitating efficient model inference. In the collected dataset, the proposed model achieved an accuracy of 99.32% and an F1-score of 99.29% in identifying eight standard views of fetal echocardiography. Furthermore, the model exhibited the lowest floating point operations per second (FLOPs), parameters, and inference time, while achieving the highest frames per second (FPS). This achievement not only provides a solid technical foundation for intelligent diagnosis of FCHD but also serves as an auxiliary tool for junior or novice sonographers at primary hospitals in acquiring basic views of fetal heart structures. Graphical Abstract


  • Open Access

    Abnormal characteristics of inferior vena cava and abdominal aorta among neonates with early onset septic shock

    by Lanlan Mi, Yiman Liu, Fei Bei, Jianhua Sun, Jun Bu, Yuqi Zhang, Weiwei Guo

    Background: The variety of shocks in neonates, if not recognized and treated immediately, is a major cause for fatality. The use of echocardiography may improve assessment and treatment, but its reference values across gestational age (GA) and birth weight (BW) are lacking. To address the information gap, this study aimed at correlating GA and BW of newborns with nonhemodynamic abnormalities, and at evaluating the usefulness of such reference values in neonates with early onset septic (EOS) -shock. Methods: A total of 200 normal newborns were enrolled as controls and subdivided into groups based on GA, BW, days of age, and patent ductus arteriosus (PDA). Echocardiography was used to document inferior vena cava diameter (IVC), inferior vena cava collapsibility index (IVC-CI), and inferior vena cava to abdominal aorta ratio (IVC/AO). In addition, 18 neonates with EOS shock were recruited and evaluated using echocardiography. Results: Among the control newborns, IVC and AO were significantly increased with GA and BW (P < 0.05) but IVC-CI and IVC/AO did not correlate with GA, BW, day of age, and PDA. Compared to the control group, the EOS-shock group had significantly decreased IVC and IVC/AO, and increased IVC-CI (P < 0.05). The cut-off values for indicating EOS-shock were > 34.15% for IVC-CI, < 47.58% for IVCmin/AO, and < 66.11% for IVCmax/AO. Conclusions: The IVC-CI, IVCmin/AO, and IVCmax/AO indices are applicable to all neonates. Although the number of neonates with EOS-shock in our study is small, the cut-off values showed usefulness for diagnosis. Further research is needed to determine the application of the indices in a larger population and among other populations, especially for clinical application in treatment of shock among neonates.