    Inter-observer variability in breast segmentation and its impact on focused ultrasound thermal therapy modeling

    by Benjamin Jackson, Nicole Peterson, Taylor Forbes, Rachel Harris, Chloe K Nelson, Amelia Martin, Brianne Geiger, Jacob Moulder, Jacob Lehnhof, David B Dahl, et al.

    Objective . Simulation-based treatment planning (SBTP) could improve magnetic resonance-guided focused ultrasound (MRgFUS) breast cancer treatments. Medical image segmentation is an essential SBTP step and may introduce uncertainty through interobserver variability. This exploratory study quantifies interobserver variability in breast magnetic resonance imaging (MRI) segmentation and assesses its impact on simulated MRgFUS breast cancer treatment outcomes. Approach. Nine researchers segmented three breast MRI. Interobserver variability amongst segmentation datasets was quantified using the surface Dice coefficient (sDICE), modified Hausdorff distance (MHD), and a multi-label, volume-weighted Dice similarity coefficient (wDICE). Segmentations were used in acoustic and thermal simulations to evaluate MRgFUS treatment outcomes including maximum temperature rise, thermal dose volume (TDV), and distance between the target location and simulated thermal center of mass (TCOM). Exploration of which labels and metrics best explained variation in treatment outcomes was performed with multiple regression using the ordinary least squares method and leave-one-out cross validation. Main results. Interobserver variability led to substantial differences in simulated outcomes, with maximum temperature changes up to 62.9 °C, TDV differences up to 324 mm 3 , and target-to-TCOM shifts as large as 3.6 mm. Regression analysis identified wDICE as a stable global metric across outcomes, while sDICE and MHD for the biopsy marker label highlighted label-specific variability. These results suggest wDICE as an overall indicator of segmentation variability for MRgFUS SBTP, with MHD and sDICE as potentially useful metrics for identifying labels where reduction of variability would be most impactful. Significance. Interobserver variability can meaningfully affect simulated MRgFUS treatment outcomes, warranting further study of clinical interobserver variability for SBTP. The exploratory regression modeling demonstrated here provides a potential methodology for identifying labels where reduction of interobserver variability would be most impactful.

  • Open Access

    Computational predictions of magnetic resonance acoustic radiation force imaging for breast cancer focused ultrasound therapy

    by Chloe K. Nelson, Michelle Kline, Allison Payne, Christopher R. Dillon

    In magnetic resonance-guided focused ultrasound (MRgFUS) breast therapies, the focal location must be characterized to guide successful treatment. Focal characterization is difficult because heterogeneous breast tissues introduce phase aberrations that blur and shift the focus and traditional guidance methods do not work in adipose tissues. The purpose of this work is to evaluate numerical simulations of MRgFUS that predict the focal location. Those simulations are compared to clinical magnetic resonance acoustic radiation force imaging (MR-ARFI) data collected during in vivo treatment of breast tumors. The focal location was evaluated before MRgFUS treatment with MR-ARFI in five patients. The hybrid angular spectrum method (HAS) was applied to simulate pressure fields which were converted to forces, then convolved with a 3D Green's function (with time-of-arrival weighting) to produce a simulation of the MR-ARFI tissue displacement. The focal locations found by the simulations and the MR-ARFI measurements were on average separated by 3.7 mm (SD: 0.9 mm). Characterization of the focal zone spatial distributions had a normalized root mean squared difference of 8.1% (SD: 2.5%). The displacement magnitudes of the simulations underestimated the MR-ARFI measurements by 82% (SD: 5.6%). The agreement between MR-ARFI measurements and simulations demonstrates that HAS can predict the in vivo focal location in heterogeneous tissues, though accurate patient-specific properties are needed to improve predictions of tissue displacement magnitude. Tools developed in this study could be used to streamline MRgFUS treatment planning and optimization, for biomechanical property estimation, and in developing phase aberration correction techniques.