Bernardo Reichert
Research Subjects
Research Interests
Bernardo Reichert has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Amanda Frota Lacerda Morais
Department of Ophthalmology and Visual Sciences, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil
1 shared publication - Anna Carolina B. Linhares
Universidade Federal do Paraná, Curitiba, PR, Brazil
1 shared publication - Luisa Moreira Hopker
Department of Ophthalmology, Hospital de Olhos do Paraná, Curitiba, PR, Brazil
1 shared publication - Murilo V. De Prá
Médicos de Olhos S.A., Curitiba, PR, Brazil
1 shared publication - Nilva Simeren Bueno de Moraes
Retina Division, Department of Ophthalmology, Escola Paulista de Medicina, Hospital São Paulo, Universidade Federal de São Paulo, São Paulo, Brazil
1 shared publication - Norma Allemann
Department of Ophthalmology and Visual Sciences, Escola Paulista de Medicina, Federal University of Sao Paulo, São Paulo, Brazil
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by GN1 Sistemas e Publicacoes Ltd. in Arquivos Brasileiros de Oftalmologia
- Vol. 88 (3) , 1-6
Retinopathy of prematurity: Accuracy of ROPScore and WINROP algorithms in a Brazilian population
Purpose: To assess the sensitivity and specificity of the retinopathy of prematurity score (ROPScore) and weight, insulin-like growth factor-1, retinopathy of prematurity algorithm in predicting the risk of developing severe retinopathy of prematurity (prethreshold type 1) in a sample of preterm infants in Brazil. Methods: Retrospective analysis of medical records of preterm infants (n=288) with birth weight of ≤1500 g and/or gestational age of 23-32 weeks in a neonatal unit in Southern Brazil from May 2013 to December 2020 (92 months). Results: The incidence of confirmed severe retinopathy of prematurity was 6.6%. ROPScore showed a 100% sensitivity, 44.6% specificity (95% confidence interval [CI] 38.7-50.6), 11.3% positive predictive value (95% CI 6.5-16.1), and 100% negative predictive value in predicting severe retinopathy of prematurity. The weight, insulin-like growth factor-1, retinopathy of prematurity algorithm demonstrated a 78.9% sensitivity (95% CI 60.6-97.3), 51.3% specificity (95% CI 45.3-57.3), 10.3% positive predictive value (95% CI 5.3-15.2), and 97.2% negative predictive value (95% CI 94.5-99.9). Conclusion: ROPScore identified all patients at risk for severe retinopathy of prematurity. These findings support incorporating ROPScore into Brazilian guidelines to optimize retinopathy of prematurity screening and reduce unnecessary ophthalmologic examinations. Weight, insulin-like growth factor-1, retinopathy of prematurity’s suboptimal performance in this Brazilian sample highlights the need for country-specific algorithm adjustments.
- 1 January 2025
- Published by GN1 Sistemas e Publicacoes Ltd. in Arquivos Brasileiros de Oftalmologia
- Vol. 88 (3) , 1-6
Open AccessRetinopathy of prematurity: Accuracy of ROPScore and WINROP algorithms in a Brazilian population
Purpose: To assess the sensitivity and specificity of the retinopathy of prematurity score (ROPScore) and weight, insulin-like growth factor-1, retinopathy of prematurity algorithm in predicting the risk of developing severe retinopathy of prematurity (prethreshold type 1) in a sample of preterm infants in Brazil. Methods: Retrospective analysis of medical records of preterm infants (n=288) with birth weight of ≤1500 g and/or gestational age of 23-32 weeks in a neonatal unit in Southern Brazil from May 2013 to December 2020 (92 months). Results: The incidence of confirmed severe retinopathy of prematurity was 6.6%. ROPScore showed a 100% sensitivity, 44.6% specificity (95% confidence interval [CI] 38.7-50.6), 11.3% positive predictive value (95% CI 6.5-16.1), and 100% negative predictive value in predicting severe retinopathy of prematurity. The weight, insulin-like growth factor-1, retinopathy of prematurity algorithm demonstrated a 78.9% sensitivity (95% CI 60.6-97.3), 51.3% specificity (95% CI 45.3-57.3), 10.3% positive predictive value (95% CI 5.3-15.2), and 97.2% negative predictive value (95% CI 94.5-99.9). Conclusion: ROPScore identified all patients at risk for severe retinopathy of prematurity. These findings support incorporating ROPScore into Brazilian guidelines to optimize retinopathy of prematurity screening and reduce unnecessary ophthalmologic examinations. Weight, insulin-like growth factor-1, retinopathy of prematurity’s suboptimal performance in this Brazilian sample highlights the need for country-specific algorithm adjustments.