Annchristin Andres
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Annchristin Andres has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Michael Roland
Applied Mechanics, Saarland University, Saarbrücken, Germany, Germany
4 shared publications - Kerstin Wickert
Applied Mechanics, Saarland University, Campus A4 2, 1. OG, 66123 Saarbrücken, Germany
3 shared publications Michael Roland
Applied Mechanics, Saarland University, Saarbrücken, Germany
3 shared publicationsStefan Diebels
Applied Mechanics, Saarland University, Saarbrücken, Germany
3 shared publications- Stefan Diebels
Applied Mechanics, Saarland University, Saarbrücken, Germany
3 shared publications Tina Histing
Department of Trauma and Reconstructive Surgery, BG Klinik Tübingen, Eberhard Karls University Tübingen, Tübingen, Germany
3 shared publications
Latest Publications
- Open Access
- 2 September 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-12
Integrated Study of the Distal Femur Biphasic Plate: Exploring In Vivo, In Vitro, and In Silico Methodologies
Purpose: An emerging concept for plate fixation of fractured bones in humans changed from absolute stability through relative stability to a new concept of a predefined range of elastic movement with mechanical amplitude limitation (“Biphasic Plate,” 41 medical, Bettlach, Switzerland). As this represents a novel implant design, only a few studies have investigated it so far, particularly with respect to human cadaveric specimens and in vivo patient-specific cases. Therefore, this study aims to investigate the biphasic behavior using in vitro, in silico, and in vivo methodologies concerning stress distributions under realistic boundary conditions. Methods: To test this, an implantable in vivo strain measurement system (“Fracture Monitor,” AO Foundation, Davos Switzerland) and a camera system are employed for experimental data acquisition, while patient monitoring captures actual boundary conditions during daily activities. Finite element simulations are performed on patient-specific 3D models generated from computed tomography imaging, allowing for detailed stress analysis. These simulations are validated through experiments on human cadaveric specimens in a custom-designed test rig by investigating the specific behavior of the biphasic plate with its two different modes (rigid and flexible). Results: Under axial loading, the stresses are distributed centrally; while in patient-specific cases, the stress pattern changes markedly, with maximum stresses concentrating along the lateral side of the plate. Conclusion: By the chosen biomechanical testing setup, the in silico simulations could be validated, demonstrating the ability to accurately replicate the postulated motion sequence of the biphasic plate. This iteration emphasizes both validation and reproducibility as the key outcomes.
- 2 September 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-12
Open AccessIntegrated Study of the Distal Femur Biphasic Plate: Exploring In Vivo, In Vitro, and In Silico Methodologies
Purpose: An emerging concept for plate fixation of fractured bones in humans changed from absolute stability through relative stability to a new concept of a predefined range of elastic movement with mechanical amplitude limitation (“Biphasic Plate,” 41 medical, Bettlach, Switzerland). As this represents a novel implant design, only a few studies have investigated it so far, particularly with respect to human cadaveric specimens and in vivo patient-specific cases. Therefore, this study aims to investigate the biphasic behavior using in vitro, in silico, and in vivo methodologies concerning stress distributions under realistic boundary conditions. Methods: To test this, an implantable in vivo strain measurement system (“Fracture Monitor,” AO Foundation, Davos Switzerland) and a camera system are employed for experimental data acquisition, while patient monitoring captures actual boundary conditions during daily activities. Finite element simulations are performed on patient-specific 3D models generated from computed tomography imaging, allowing for detailed stress analysis. These simulations are validated through experiments on human cadaveric specimens in a custom-designed test rig by investigating the specific behavior of the biphasic plate with its two different modes (rigid and flexible). Results: Under axial loading, the stresses are distributed centrally; while in patient-specific cases, the stress pattern changes markedly, with maximum stresses concentrating along the lateral side of the plate. Conclusion: By the chosen biomechanical testing setup, the in silico simulations could be validated, demonstrating the ability to accurately replicate the postulated motion sequence of the biphasic plate. This iteration emphasizes both validation and reproducibility as the key outcomes.
- Open Access
- 25 September 2025
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 13, 1659029
Predicting the effect of individual weight-bearing on tibial load and fracture healing after tibial plateau fractures–introduction of a biomechanical simulation model
Purpose: The prescribed amount of weight-bearing after tibial plateau fractures is controversial because it affects osteosynthetic construct stability and fracture healing. We aim to introduce a simulation model that adequately predicts the effects of different weight-bearing amounts on stability and healing, based on the patient’s individual fracture pattern and treatment construct.Methods: To safely test different amounts of weight-bearing limits, we first extracted knee joint forces for different weight-bearing limits from musculoskeletal simulation based on monitoring data of 22 uninjured participants. Correct loading was ensured with a force-measuring insole. We then tested three patients after tibial plateau fracture with their current weight-bearing level and constructed a simulation model determining implant stress, knee joint force, and fracture gap interfragmentary strain. The patient-specific weight-bearing level was then substituted for weight-normalized uninjured participant data to test different weight-bearing levels in the simulation model.Results: The simulation model calculated individual construct stiffness and interfragmentary strain at different weight-bearing levels following the clinical course. When comparing the patient’s individual weight-bearing input with the weight-normalized input of the uninjured participants at the same level, comparable knee joint forces were extracted, showing the feasibility of this approach.Conclusion: Using an adapted reference movement database, the model allows the determination of safe weight-bearing ranges concerning construct stability and fracture healing based on individual fracture morphology and treatment without exposing patients to excessive weight-bearing. Future studies can test this approach in more extensive patient-number studies and different treatment situations.
- 25 September 2025
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 13, 1659029
Open AccessPredicting the effect of individual weight-bearing on tibial load and fracture healing after tibial plateau fractures–introduction of a biomechanical simulation model
Purpose: The prescribed amount of weight-bearing after tibial plateau fractures is controversial because it affects osteosynthetic construct stability and fracture healing. We aim to introduce a simulation model that adequately predicts the effects of different weight-bearing amounts on stability and healing, based on the patient’s individual fracture pattern and treatment construct.Methods: To safely test different amounts of weight-bearing limits, we first extracted knee joint forces for different weight-bearing limits from musculoskeletal simulation based on monitoring data of 22 uninjured participants. Correct loading was ensured with a force-measuring insole. We then tested three patients after tibial plateau fracture with their current weight-bearing level and constructed a simulation model determining implant stress, knee joint force, and fracture gap interfragmentary strain. The patient-specific weight-bearing level was then substituted for weight-normalized uninjured participant data to test different weight-bearing levels in the simulation model.Results: The simulation model calculated individual construct stiffness and interfragmentary strain at different weight-bearing levels following the clinical course. When comparing the patient’s individual weight-bearing input with the weight-normalized input of the uninjured participants at the same level, comparable knee joint forces were extracted, showing the feasibility of this approach.Conclusion: Using an adapted reference movement database, the model allows the determination of safe weight-bearing ranges concerning construct stability and fracture healing based on individual fracture morphology and treatment without exposing patients to excessive weight-bearing. Future studies can test this approach in more extensive patient-number studies and different treatment situations.
- Open Access
From Injury to Full Recovery: Monitoring Patient Progress Through Advanced Sensor and Motion Capture Technology
Background: Advanced sensor insoles and motion capture technology can significantly enhance the monitoring of rehabilitation progress for patients with distal tibial fractures. This study leverages the potential of these innovative tools to provide a more comprehensive assessment of a patient’s gait and weight-bearing capacity following surgical intervention, thereby offering the possibility of improved patient outcomes. Methods: A patient who underwent distal medial tibial plating surgery in August 2023 and subsequently required revision surgery due to implant failure, involving plate removal and the insertion of an intramedullary nail in December 2023, was meticulously monitored over a 12-week period. Initial assessments in November 2023 revealed pain upon full weight-bearing without crutches. Following the revision, precise weekly measurements were taken, starting two days after surgery, which instilled confidence in accurately tracking the patient’s progress from initial crutch-assisted walking to full recovery. The monitoring tools included insoles, hand pads for force absorption of the crutches, and a motion capture system. The patient was accompanied throughout all steps of his daily life. Objectives: The study aimed to evaluate the hypothesis that the approximation and formation of a healthy gait curve are decisive tools for monitoring healing. Specifically, it investigated whether cadence, imbalance factors, and ground reaction forces could be significant indicators of healing status and potential disorders. Results: The gait parameters, cadence, factor of imbalance ground reaction forces, and the temporal progression of kinematic parameters significantly correlate with the patient’s recovery trajectory. These metrics enable the early identification of deviations from expected healing patterns, facilitating timely interventions and underscoring the transformative potential of these technologies in patient care. Conclusions: Integrating sensor insoles and motion capture technology offers a promising approach for monitoring the recovery process in patients with distal tibial fractures. This method provides valuable insights into the patient’s healing status, potentially predicting and addressing healing disorders more effectively. Future studies are recommended to validate these findings in a larger cohort and explore the potential integration of these technologies into clinical practice.
Open AccessFrom Injury to Full Recovery: Monitoring Patient Progress Through Advanced Sensor and Motion Capture Technology
Background: Advanced sensor insoles and motion capture technology can significantly enhance the monitoring of rehabilitation progress for patients with distal tibial fractures. This study leverages the potential of these innovative tools to provide a more comprehensive assessment of a patient’s gait and weight-bearing capacity following surgical intervention, thereby offering the possibility of improved patient outcomes. Methods: A patient who underwent distal medial tibial plating surgery in August 2023 and subsequently required revision surgery due to implant failure, involving plate removal and the insertion of an intramedullary nail in December 2023, was meticulously monitored over a 12-week period. Initial assessments in November 2023 revealed pain upon full weight-bearing without crutches. Following the revision, precise weekly measurements were taken, starting two days after surgery, which instilled confidence in accurately tracking the patient’s progress from initial crutch-assisted walking to full recovery. The monitoring tools included insoles, hand pads for force absorption of the crutches, and a motion capture system. The patient was accompanied throughout all steps of his daily life. Objectives: The study aimed to evaluate the hypothesis that the approximation and formation of a healthy gait curve are decisive tools for monitoring healing. Specifically, it investigated whether cadence, imbalance factors, and ground reaction forces could be significant indicators of healing status and potential disorders. Results: The gait parameters, cadence, factor of imbalance ground reaction forces, and the temporal progression of kinematic parameters significantly correlate with the patient’s recovery trajectory. These metrics enable the early identification of deviations from expected healing patterns, facilitating timely interventions and underscoring the transformative potential of these technologies in patient care. Conclusions: Integrating sensor insoles and motion capture technology offers a promising approach for monitoring the recovery process in patients with distal tibial fractures. This method provides valuable insights into the patient’s healing status, potentially predicting and addressing healing disorders more effectively. Future studies are recommended to validate these findings in a larger cohort and explore the potential integration of these technologies into clinical practice.
- Top Cited PapersOpen Access
- 6 June 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Advantages of digital twin technology in orthopedic trauma Surgery – Exploring different clinical use cases
Digital twin technology offers significant benefits for addressing fracture non-unions in orthopedic trauma surgery, particularly in cases requiring revision surgery. In this study, we developed a clinically applicable digital twin workflow that integrates patient-specific imaging, motion capture, musculoskeletal modeling, and finite element simulation. We applied this workflow to five real patient cases involving different anatomical sites and treatment strategies, including implant modification, augmentative fixation, and corrective osteotomy. Each case was virtually reconstructed to evaluate mechanical conditions before and after revision surgery. The results demonstrated that digital twins can predict improvements in implant stress distribution and fracture strain states, offering valuable insights for optimizing surgical decisions. This work highlights the feasibility of digital twins and their clinical value in supporting individualized revision strategies, laying the foundation for their broader use in trauma care. .
- 6 June 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Top Cited PapersOpen AccessAdvantages of digital twin technology in orthopedic trauma Surgery – Exploring different clinical use cases
Digital twin technology offers significant benefits for addressing fracture non-unions in orthopedic trauma surgery, particularly in cases requiring revision surgery. In this study, we developed a clinically applicable digital twin workflow that integrates patient-specific imaging, motion capture, musculoskeletal modeling, and finite element simulation. We applied this workflow to five real patient cases involving different anatomical sites and treatment strategies, including implant modification, augmentative fixation, and corrective osteotomy. Each case was virtually reconstructed to evaluate mechanical conditions before and after revision surgery. The results demonstrated that digital twins can predict improvements in implant stress distribution and fracture strain states, offering valuable insights for optimizing surgical decisions. This work highlights the feasibility of digital twins and their clinical value in supporting individualized revision strategies, laying the foundation for their broader use in trauma care. .
- Open Access
- 20 May 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (5) , 545
Simulation of a Custom-Made Temporomandibular Joint—An Academic View on an Industrial Workflow
Temporomandibular joint replacement is a critical intervention for severe temporomandibular joint disorders, enhancing pain levels, jaw function and overall quality of life. In this study, we compare two finite element method-based simulation workflows from both academic and industrial perspectives, focusing on a patient-specific case involving a custom-made temporomandibular joint prosthesis. Using computed tomography data and computer-aided design data, we generated different 3D models and performed mechanical testing, including wear and static compression tests. Our results indicate that the academic workflow, which is retrospective, purely image-based and applied post-operatively, produced peak stress values within 9–20% of those obtained from the industrial workflow. The industrial workflow is prospective, pre-operative, computer-aided design-based and guided by stringent regulatory standards and approval protocols. Observed differences between workflows were attributed primarily to distinct modelling assumptions, simplifications and constraints inherent in each method. To explicitly quantify these differences, multiple additional models were generated within the academic workflow using partial data from the industrial process, revealing specific sources of variation in stress distribution and implant performance. The findings underscore the potential of patient-specific simulations not only to refine temporomandibular joint prosthesis design and enhance patient outcomes, but also to highlight the interplay between academic research methodologies and industrial standards in the development of medical devices.
- 20 May 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (5) , 545
Open AccessSimulation of a Custom-Made Temporomandibular Joint—An Academic View on an Industrial Workflow
Temporomandibular joint replacement is a critical intervention for severe temporomandibular joint disorders, enhancing pain levels, jaw function and overall quality of life. In this study, we compare two finite element method-based simulation workflows from both academic and industrial perspectives, focusing on a patient-specific case involving a custom-made temporomandibular joint prosthesis. Using computed tomography data and computer-aided design data, we generated different 3D models and performed mechanical testing, including wear and static compression tests. Our results indicate that the academic workflow, which is retrospective, purely image-based and applied post-operatively, produced peak stress values within 9–20% of those obtained from the industrial workflow. The industrial workflow is prospective, pre-operative, computer-aided design-based and guided by stringent regulatory standards and approval protocols. Observed differences between workflows were attributed primarily to distinct modelling assumptions, simplifications and constraints inherent in each method. To explicitly quantify these differences, multiple additional models were generated within the academic workflow using partial data from the industrial process, revealing specific sources of variation in stress distribution and implant performance. The findings underscore the potential of patient-specific simulations not only to refine temporomandibular joint prosthesis design and enhance patient outcomes, but also to highlight the interplay between academic research methodologies and industrial standards in the development of medical devices.
- Open Access
- 23 March 2025
- Published by Elsevier in Clinical Biomechanics
- p. 106503
Individual postoperative and preoperative workflow for patients with fractures of the lower extremities
- 23 March 2025
- Published by Elsevier in Clinical Biomechanics
- p. 106503
Open AccessIndividual postoperative and preoperative workflow for patients with fractures of the lower extremities
- Open Access
- 30 January 2025
- Published by MDPI AG in Preprints.org
Simulation of a Custom-Made Temporomandibular Joint –an Academic View on an Industrial Workflow
Temporomandibular joint replacement is a critical intervention for severe temporomandibular joint disorders, enhancing pain levels, jaw function, and overall quality of life. In this study, we compare two finite element method-based simulation workflows from both academic and industrial perspectives, focusing on a patient-specific case involving a custom-made temporomandibular joint prosthesis. Using computed tomography data and computer-aided design data, we generated different 3D models and performed mechanical testing, including wear and static compression tests. The results demonstrate that the academic, retrospective, and purely image-based approach, applied post-operatively, yields biomechanical insights comparable to those derived from the industrial, pre-operative, planning-based process, which is additionally guided by regulatory requirements and approval protocols. Minor variations between the two workflows are primarily due to different assumptions, simplifications and constraints imposed by the regulatory framework. To elaborate the differences, various models were generated in the academic workflow, partly based on the data of the industrial process. These findings underscore the potential of patient-specific simulations not only to refine temporomandibular joint prosthesis design and enhance patient outcomes, but also to highlight the interplay between academic research methodologies and industrial standards in the development of medical devices.
- 30 January 2025
- Published by MDPI AG in Preprints.org
Open AccessSimulation of a Custom-Made Temporomandibular Joint –an Academic View on an Industrial Workflow
Temporomandibular joint replacement is a critical intervention for severe temporomandibular joint disorders, enhancing pain levels, jaw function, and overall quality of life. In this study, we compare two finite element method-based simulation workflows from both academic and industrial perspectives, focusing on a patient-specific case involving a custom-made temporomandibular joint prosthesis. Using computed tomography data and computer-aided design data, we generated different 3D models and performed mechanical testing, including wear and static compression tests. The results demonstrate that the academic, retrospective, and purely image-based approach, applied post-operatively, yields biomechanical insights comparable to those derived from the industrial, pre-operative, planning-based process, which is additionally guided by regulatory requirements and approval protocols. Minor variations between the two workflows are primarily due to different assumptions, simplifications and constraints imposed by the regulatory framework. To elaborate the differences, various models were generated in the academic workflow, partly based on the data of the industrial process. These findings underscore the potential of patient-specific simulations not only to refine temporomandibular joint prosthesis design and enhance patient outcomes, but also to highlight the interplay between academic research methodologies and industrial standards in the development of medical devices.