MSMarwan Ahmad Abdullah Sufyan

Marwan Ahmad Abdullah Sufyan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marwan Ahmad Abdullah Sufyan has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Mohd Zuhaib

    Department of Electrical Engineering, GLA University, Mathura, India

    2 shared publications
  • Saket Gupta

    Department of Instrumentation and Control Engineering, Bharati Vidyapeeth's College of Engineering, Delhi, 110063, India

    2 shared publications
  • Jai Prakash Sharma

    Department of Electrical Engineering, GLA University, Mathura, India

    1 shared publication
  • Mohd Rihan

    Department of Electrical Engineering, Aligarh Muslim University, Aligarh, India

    1 shared publication
  • Mohd Zuhaib

    Department of Electrical Engineering, GLA University, Mathura, Uttar Pradesh, India.

    1 shared publication
  • Narendra Kumar

    Department of Electrical Engineering, Delhi Technological University, Delhi, India

    1 shared publication

Latest Publications

  • Open Access

    Parameter-free hybrid RAO algorithm for reactive power optimization

    by Upma Singh, Saket Gupta, Mohd Zuhaib, Marwan Ahmad Abdullah Sufyan

    The Rao algorithms are a relatively new parameter-free optimisation technique that has grown in importance as an intelligent optimisation tool. Rao algorithms are effective algorithms that embody the idea of attracting toward a global optimum, illustrating the algorithm’s swarm intelligence and the survival of the fittest principle, like that of an evolutionary algorithm. However, it has found applications in other areas related to optimization, primarily in engineering practice, where it is analyzed and summarized based on the specifics of each situation. The absence of algorithm-specific parameters explains the wide applicability of Rao optimization. Although several studies have addressed these methods, limited effort has been made to provide a comprehensive summary of Rao algorithms. This work aims to provide up-to-date information on Rao algorithms, which will be useful for researchers in this field. Additionally, a hybrid Rao algorithm is developed to overcome the limitations of traditional Rao algorithms. The proposed algorithm was implemented in the IEEE 30-bus and IEEE 57 bus systems, to resolve the Optimal VAR Dispatch Problem, and to assess its effectiveness. Results show that hybrid Rao algorithm deliver higher quality solutions within a reasonable timeframe, outperforming other approaches stated in the recent literature. The paper ends with recommendations for future developments to improve the Rao algorithm’s performance.

  • Open Access

    Optimal AGC regulators for power systems under restructured configuration with hybrid ESS

    by Ram Naresh Mishra, Narendra Kumar, Mohd Zuhaib, Marwan Ahmad Abdullah Sufyan

    Several new rivals are entering the market as a result of the global restructuring of the electric power sector, which is also intensifying competition among existing market players. Better services, greater choices, and less expensive power are all intended to benefit consumers. For such systems to be more reliable, new control techniques with hybrid ESS are crucial. The CSOA-based hybrid ESS for a restructured T-G-S power system combines a polar fuzzy controller (PFC) with an FOPID controller. Testing is done on this controller’s resilience with CTD, random load demand, and parameter uncertainty. Additionally, a reconstructed N-G-S system is used to assess the viability of the suggested controller. A CSOA-based combined FOPID controller and polar fuzzy controller using hybrid ESS can improve frequency responses for Area-1 and Area-2 by 15.59% and 21.83%, respectively, and enhance the response of power variation of the tie-line under contract violation by 27.16% when compared to the CSOA: PIIʎDDµ controller. The effectiveness of a CSOA-based combination (1 + FOID) controller and a polar fuzzy controller for a restructured T-H-G power system is demonstrated in another study. Other controllers, including GA: 1 + PFC, SOA: FOPID, SOA: PID, GA: PID, and OARs, are used to verify its performance. These controllers include a variety of linkages, including a control variable ∆Pdc with the turbine’s controller. The proposed control scheme has the lowest cost function among various control strategies and has been shown to outperform several existing control methods. Moreover, it offers incredibly dependable performance under different load conditions.


  • Open Access

    Extension of pole differential current based relaying for bipolar LCC HVDC lines

    by Ravi Shankar Tiwari, Jai Prakash Sharma, Om Hari Gupta, Marwan Ahmed Abdullah Sufyan

    Line commutated converter (LCC) based high-voltage direct current (HVDC) transmission is characterized by long-distance power transfer, a complex and harsh corridor environment, and the rapid fault evolution of DC lines. Since high fault currents can potentially cause unalterable destruction to power devices, fast and reliable line protection and isolation are essential to enhance the security and reliability of LCC-HVDC transmission systems. This paper combines an extended relaying using single- and double-ended measurements of the transient current at the boundary of positive and negative polarity DC lines to meet this obligation. During a fault, the DC line equivalent circuit is initially analysed with the time domain response of positive and negative polarity DC line (poles) currents at two ends to define local and global pole differential currents (PDCs). The criterion of relaying is then developed using PDCs for the bipolar and monopolar modes of operation of the LCC-HVDC transmission system. The proposed relaying method is validated through simulation, with results indicating that it can quickly (within 5.1 ms) and reliably detect internal faults and remain stable during external faults, accurately identify faulty poles without requiring data communication synchronization for bipolar operation, and demonstrate strong transition resistance. However, the monopolar operation uses global PDC to detect faults reliably within 15.6 ms. The proposed scheme is implemented on a 2000 MW, ± 500 kV, 900 km bipolar LCC-HVDC transmission system, simulated using PSCAD/EMTDC software. Additionally, the results are analyzed using MATLAB/Simulink.


  • Open Access

    Identification and suppression of low-frequency oscillations using PMU measurements based power system model in smart grid

    by Mohd Zuhaib, Mohd Rihan, Saket Gupta, Marwan Ahmad Abdullah Sufyan

    Low-frequency oscillations (LFO) are inherent to large interconnected power systems. Timely detection and mitigation of these oscillations is essential to maintain reliable power system operation. This paper presents a methodology to identify and mitigate low-frequency oscillations ( forced and inter-area) using a wide area monitoring system (WAMS) based power system model utilizing phasor measurement units (PMUs). These models accurately identify the behavior and location of generators contributing to low-frequency oscillations in real-time and hence can efficiently improve the performance of WADC to mitigate them. The proportional resonant power system stabilizer (PR-PSS) is utilized to suppress these LFOs, as determined from the Wide Area Power System Model. The damping structure based on PR-PSS with measurements from WAMS effectively suppresses both forced and inter-area oscillation modes.