Jochen De Vry
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jochen De Vry has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Anaïs Vanbuel
Reval Rehabilitation Research Center, Faculty of Rehabilitation Sciences, Hasselt University, 3590 Diepenbeek, Belgium
1 shared publication - Annemie Spooren
Centre of Expertise in Care Innovation, Department of PXL—Healthcare, PXL University of Applied Sciences and Arts, 3500 Hasselt, Belgium
1 shared publication - Britt Sourbron
Reval Rehabilitation Research Center, Faculty of Rehabilitation Sciences, Hasselt University, 3590 Diepenbeek, Belgium
1 shared publication - Bruno Bonnechère
University of Hasselt
1 shared publication - Dominique Hansen
Rehabilitation Research Center (REVAL), Faculty of Rehabilitation Sciences, Hasselt University , Wetenschapspark 7, Diepenbeek 3590
1 shared publication - Hans Van Alphen
Centre of Expertise in Care Innovation, Department of PXL—Healthcare, PXL University of Applied Sciences and Arts, 3500 Hasselt, Belgium
1 shared publication
Latest Publications
- Open Access
From Steps to Context: Optimizing Digital Phenotyping for Physical Activity Monitoring in Older Adults by Integrating Wearable Data and Ecological Momentary Assessment
Physical activity (PA) is essential for healthy aging, but its accurate assessment in older adults remains challenging due to the limitations and biases of traditional clinical assessment. Mobile technologies and wearable sensors offer a more ecological, less biased alternative for evaluating PA in this population. This study aimed to optimize digital phenotyping strategies for assessing PA patterns in older adults, by integrating ecological momentary assessment (EMA) and continuous wearable sensor data collection. Over two weeks, 108 community-dwelling older adults provided real-time EMA responses while their PA was continuously monitored using Garmin Vivo 5 sensors. The combined approach proved feasible, with 67.2% adherence to EMA prompts, consistent across time points (morning: 68.1%; evening: 65.4%). PA predominantly occurred at low (51.4%) and moderate (46.2%) intensities, with midday activity peaks. Motivation and self-efficacy were significantly associated with low-intensity PA (R = 0.20 and 0.14 respectively), particularly in the morning. However, discrepancies between objective step counts and self-reported PA measures, which showed no correlation (R = −0.026, p = 0.65), highlight the complementary value of subjective and objective data sources. These findings support integrating EMA, wearable sensors, and temporal frameworks to enhance PA assessment, offering precise insights for personalized, time-sensitive interventions to promote PA.
Open AccessFrom Steps to Context: Optimizing Digital Phenotyping for Physical Activity Monitoring in Older Adults by Integrating Wearable Data and Ecological Momentary Assessment
Physical activity (PA) is essential for healthy aging, but its accurate assessment in older adults remains challenging due to the limitations and biases of traditional clinical assessment. Mobile technologies and wearable sensors offer a more ecological, less biased alternative for evaluating PA in this population. This study aimed to optimize digital phenotyping strategies for assessing PA patterns in older adults, by integrating ecological momentary assessment (EMA) and continuous wearable sensor data collection. Over two weeks, 108 community-dwelling older adults provided real-time EMA responses while their PA was continuously monitored using Garmin Vivo 5 sensors. The combined approach proved feasible, with 67.2% adherence to EMA prompts, consistent across time points (morning: 68.1%; evening: 65.4%). PA predominantly occurred at low (51.4%) and moderate (46.2%) intensities, with midday activity peaks. Motivation and self-efficacy were significantly associated with low-intensity PA (R = 0.20 and 0.14 respectively), particularly in the morning. However, discrepancies between objective step counts and self-reported PA measures, which showed no correlation (R = −0.026, p = 0.65), highlight the complementary value of subjective and objective data sources. These findings support integrating EMA, wearable sensors, and temporal frameworks to enhance PA assessment, offering precise insights for personalized, time-sensitive interventions to promote PA.