JNJ. Nyman

J. Nyman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


J. Nyman has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • C. Rundby

    Karolinska Institutet, Department of Molecular Medicine and Surgery, Department of Cardiothoracic Surgery and Anesthesiology, Karolinska University Hospital, Stockholm, Sweden

    1 shared publication
  • J. van der Linden

    Karolinska Institutet, Department of Molecular Medicine and Surgery, Department of Cardiothoracic Surgery and Anesthesiology, Karolinska University Hospital, Stockholm, Sweden

    1 shared publication
  • P. Svenarud

    Karolinska Institutet, Department of Molecular Medicine and Surgery, Department of Cardiothoracic Surgery and Anesthesiology, Karolinska University Hospital, Stockholm, Sweden

    1 shared publication

Latest Publications

  • Does CO 2 flushing of the empty CPB circuit decrease the number of gaseous emboli in the prime?

    by J. Nyman, C. Rundby, P. Svenarud, J. van der Linden

    Twenty (20) CPB-circuits were randomized to a CO2 group or a control group. In the CO 2 group, each circuit was flushed with CO2 (10L/min) at the top of the venous reservoir for 5 minutes, after which priming fluid was added without interruption of the CO2 inflow. Control group circuits were not flushed and contained air. A perfusionist, blinded to the study, started the pump (5L/min), ventilated the oxygenator (3L O2/min), and knocked on the oxygenator 20 times during the first and 14th minutes. Arterial line microemboli counts were registered with a Doppler for 15 minutes. In both groups, the median number of microemboli was highest during the first minute, 380.5 (288.75/422.25, 25th/75th percentile) counts in the control group versus 264.5 (171.75/422.25) counts in the CO 2 group (p=0.01). Throughout the experiment, the median microembolic count minute by minute in the CO2 group remained lower (p≤ 0 .004) than in the control group. Knocking on the reservoir (14th minute) increased the microemboli counts in both groups (pth minute were 15.5 and 0.5 in the control and the CO2 groups, respectively, which were 9% (15.5/173) and 0.5% (0.5/87), respectively, of the values registered after 14 minutes. In conclusion, CO 2 flushing of the empty circuit decreases the number of gaseous emboli in the prime compared with a conventional circuit that contains air before being primed with fluid. Knocking of the oxygenator releases gaseous emboli and the duration of re-circulating the circuit with prime influences the number of microemboli.