Matt J. Owen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Matt J. Owen has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Gary Richard Mirams
Centre for Mathematical Medicine and Biology, School of Mathematical Sciences, University of Nottingham, Nottingham, United Kingdom
3 shared publications - Aldo Rona
School of Engineering, University of Leicester, Leicester LE1 7RH, UK
1 shared publication - Alison H. Goodall
Department of Cardiovascular Sciences, University of Leicester and NIHR Cardiovascular Biomedical Research Unit, Glenfield Hospital, Leicester, UK
1 shared publication - Andrea Cangiani
Department of Mathematics, University of Leicester, University Road, Leicester LE1 7RH, UK
1 shared publication - Antonio Francesco Corno
Faculty of Science and Engineering, Manchester Metropolitan University, Manchester, UK
1 shared publication - Edward G. D. Tuddenham
UCL, Rye, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 2 April 2026
- Published by Elsevier in Physica D: Nonlinear Phenomena
- Vol. 492
Continuation methods as a tool for parameter inference in models of biological oscillations: A case study in electrophysiology modeling
- 2 April 2026
- Published by Elsevier in Physica D: Nonlinear Phenomena
- Vol. 492
Open AccessContinuation methods as a tool for parameter inference in models of biological oscillations: A case study in electrophysiology modeling
- Open Access
- 14 August 2025
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 21 (8) , e1013319
IonBench: A benchmark of optimisation strategies for mathematical models of ion channel currents
Ion channel models present many challenging optimisation problems. These include unidentifiable parameters, noisy data, unobserved states, and a combination of both fast and slow timescales. This can make it difficult to choose a suitable optimisation routine a priori. Nevertheless, many attempts have been made to design optimisation routines specifically for ion channel models, however, little work has been done to compare these optimisation approaches. We have developed ionBench, an open-source optimisation benchmarking framework, to evaluate and compare these approaches against a standard set of ion channel optimisation problems. We included implementations of thirty-four unique optimisation approaches that have been previously applied to ion channel models and evaluated them against the ionBench test suite, consisting of five parameter optimisation problems derived from the cardiac ion channel literature. Each optimisation approach was initiated from multiple starting parameters and tasked with reproducing a problem-specific simulated dataset. Through ionBench, we tracked and evaluated the performance of these optimisations, identifying the expected run time until a successful optimisation for each approach, which was used for comparisons. Finally, we used these results, in addition to other literature results, to identify a new efficient approach. Its use could reduce computation time by multiple orders of magnitude, while also improving the reliability of ion channel parameter optimisation.
- 14 August 2025
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 21 (8) , e1013319
Open AccessIonBench: A benchmark of optimisation strategies for mathematical models of ion channel currents
Ion channel models present many challenging optimisation problems. These include unidentifiable parameters, noisy data, unobserved states, and a combination of both fast and slow timescales. This can make it difficult to choose a suitable optimisation routine a priori. Nevertheless, many attempts have been made to design optimisation routines specifically for ion channel models, however, little work has been done to compare these optimisation approaches. We have developed ionBench, an open-source optimisation benchmarking framework, to evaluate and compare these approaches against a standard set of ion channel optimisation problems. We included implementations of thirty-four unique optimisation approaches that have been previously applied to ion channel models and evaluated them against the ionBench test suite, consisting of five parameter optimisation problems derived from the cardiac ion channel literature. Each optimisation approach was initiated from multiple starting parameters and tasked with reproducing a problem-specific simulated dataset. Through ionBench, we tracked and evaluated the performance of these optimisations, identifying the expected run time until a successful optimisation for each approach, which was used for comparisons. Finally, we used these results, in addition to other literature results, to identify a new efficient approach. Its use could reduce computation time by multiple orders of magnitude, while also improving the reliability of ion channel parameter optimisation.
- Open Access
IonBench: a benchmark of optimisation strategies for mathematical models of ion channel currents
Ion channel models present many challenging optimisation problems. These include unidentifiable parame- ters, noisy data, unobserved states, and a combination of both fast and slow timescales. This can make it difficult to choose a suitable optimisation routine a priori . Nevertheless, many attempts have been made to design optimisation routines specifically for ion channel models, however, little work has been done to compare these optimisation approaches. We have developed ionBench, an open-source optimisation bench- marking framework, to evaluate and compare these approaches against a standard set of ion channel optimisation problems. We included implementations of thirty-four unique optimisation approaches that have been previously applied to ion channel models and evaluated them against the ionBench test suite, consisting of five parameter optimisation problems derived from the cardiac ion channel literature. Each optimisation approach was initiated from multiple starting parameters and tasked with reproducing a problem-specific simulated dataset. Through ionBench, we tracked and evaluated the performance of these optimisations, identifying the expected run time until a successful optimisation for each approach, which was used for comparisons. Finally, we used these results, in addition to other literature results, to identify a new efficient approach. Its use could reduce computation time by multiple orders of magnitude, while also improving the reliability of ion channel parameter optimisation.
Open AccessIonBench: a benchmark of optimisation strategies for mathematical models of ion channel currents
Ion channel models present many challenging optimisation problems. These include unidentifiable parame- ters, noisy data, unobserved states, and a combination of both fast and slow timescales. This can make it difficult to choose a suitable optimisation routine a priori . Nevertheless, many attempts have been made to design optimisation routines specifically for ion channel models, however, little work has been done to compare these optimisation approaches. We have developed ionBench, an open-source optimisation bench- marking framework, to evaluate and compare these approaches against a standard set of ion channel optimisation problems. We included implementations of thirty-four unique optimisation approaches that have been previously applied to ion channel models and evaluated them against the ionBench test suite, consisting of five parameter optimisation problems derived from the cardiac ion channel literature. Each optimisation approach was initiated from multiple starting parameters and tasked with reproducing a problem-specific simulated dataset. Through ionBench, we tracked and evaluated the performance of these optimisations, identifying the expected run time until a successful optimisation for each approach, which was used for comparisons. Finally, we used these results, in addition to other literature results, to identify a new efficient approach. Its use could reduce computation time by multiple orders of magnitude, while also improving the reliability of ion channel parameter optimisation.
- Open Access
- 22 March 2024
- Published by Elsevier in Journal of Thrombosis and Haemostasis
- Vol. 22 (6) , 1689-1703
Mathematical models of coagulation—are we there yet?
- 22 March 2024
- Published by Elsevier in Journal of Thrombosis and Haemostasis
- Vol. 22 (6) , 1689-1703
Open AccessMathematical models of coagulation—are we there yet?
- Open Access
- 24 May 2019
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 7, 196
Physiological Fontan Procedure
Objective: The conventional Fontan circulation deviates the superior vena cava (SVC = 1/3 of the systemic venous return) toward the right lung (3/5 of total lung volume) and the inferior vena cava (IVC = 2/3 of the systemic venous return) toward the left lung (2/5 of total lung volume). A “physiological” Fontan deviating the SVC toward the left lung and the IVC toward the right lung was compared with the conventional setting by computational fluid dynamics, studying whether this setting achieves a more favorable hemodynamics than the conventional Fontan circulation. Materials and Methods: An in-silico 3D parametric model of the Fontan procedure was developed using idealized vascular geometries with invariant sizes of SVC, IVC, right pulmonary artery (RPA), and left pulmonary artery (LPA), steady inflow velocities at IVC and SVC, and constant equal outflow pressures at RPA and LPA. These parameters were set to perform finite-volume incompressible steady flow simulations, assuming a single-phase, Newtonian, isothermal, laminar blood flow. Numerically converged finite-volume mass and momentum flow balances determined the inlet pressures and the outflow rates. Numerical closed-path integration of energy fluxes across domain boundaries determined the flow energy loss rate through the Fontan circulation. The comparison evaluated: (1) mean IVC pressure; (2) energy loss rate; (3) kinetic energy maximum value throughout the domain volume. Results: The comparison of the physiological vs. conventional Fontan provided these results: (1) mean IVC pressure 13.9 vs. 14.1 mmHg (= 0.2 mmHg reduction); (2) energy loss rate 5.55 vs. 6.61 mW (= 16% reduction); (3) maximum kinetic energy 283 vs. 396 J/m3 (= 29% reduction). Conclusions: A more physiological flow distribution is accompanied by a reduction of mean IVC pressure and by substantial reductions of energy loss rate and of peak kinetic energy. The potential clinical impact of these hemodynamic changes in reducing the incidence and severity of the adverse long-term effects of the Fontan circulation, in particular liver failure and protein-losing enteropathy, still remains to be assessed and will be the subject of future work.
- 24 May 2019
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 7, 196
Open AccessPhysiological Fontan Procedure
Objective: The conventional Fontan circulation deviates the superior vena cava (SVC = 1/3 of the systemic venous return) toward the right lung (3/5 of total lung volume) and the inferior vena cava (IVC = 2/3 of the systemic venous return) toward the left lung (2/5 of total lung volume). A “physiological” Fontan deviating the SVC toward the left lung and the IVC toward the right lung was compared with the conventional setting by computational fluid dynamics, studying whether this setting achieves a more favorable hemodynamics than the conventional Fontan circulation. Materials and Methods: An in-silico 3D parametric model of the Fontan procedure was developed using idealized vascular geometries with invariant sizes of SVC, IVC, right pulmonary artery (RPA), and left pulmonary artery (LPA), steady inflow velocities at IVC and SVC, and constant equal outflow pressures at RPA and LPA. These parameters were set to perform finite-volume incompressible steady flow simulations, assuming a single-phase, Newtonian, isothermal, laminar blood flow. Numerically converged finite-volume mass and momentum flow balances determined the inlet pressures and the outflow rates. Numerical closed-path integration of energy fluxes across domain boundaries determined the flow energy loss rate through the Fontan circulation. The comparison evaluated: (1) mean IVC pressure; (2) energy loss rate; (3) kinetic energy maximum value throughout the domain volume. Results: The comparison of the physiological vs. conventional Fontan provided these results: (1) mean IVC pressure 13.9 vs. 14.1 mmHg (= 0.2 mmHg reduction); (2) energy loss rate 5.55 vs. 6.61 mW (= 16% reduction); (3) maximum kinetic energy 283 vs. 396 J/m3 (= 29% reduction). Conclusions: A more physiological flow distribution is accompanied by a reduction of mean IVC pressure and by substantial reductions of energy loss rate and of peak kinetic energy. The potential clinical impact of these hemodynamic changes in reducing the incidence and severity of the adverse long-term effects of the Fontan circulation, in particular liver failure and protein-losing enteropathy, still remains to be assessed and will be the subject of future work.