Anna De Cet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anna De Cet has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Pasquale Vena
Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Laboratory of Biological Structure Mechanics (LaBS), Politecnico di Milano, Milan, Italy
4 shared publications - Luca D'ANdrea
Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Laboratory of Biological Structure Mechanics (LaBS), Politecnico di Milano, Milan, Italy
3 shared publications - Dario Gastaldi
“Giulio Natta”—LaBS, Department of Chemistry, Materials and Chemical Engineering, Politecnico di Milano, Milan, Italy
2 shared publications - Martina Colombo
Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Laboratory of Biological Structure Mechanics (LaBS), Politecnico di Milano, Milan, Italy
2 shared publications - Andrea Sardella
Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
1 shared publication Dario Alidoost
1 shared publication
Latest Publications
- Open Access
- 9 July 2026
- Published by MDPI AG in Biomimetics
- Vol. 11 (7) , 479
Strategic Placement of Pores to Modulate Toughness in Hydroxyapatite Bone Scaffolds Fixation
Hydroxyapatite-based ceramic scaffolds are attractive for bone tissue engineering but are prone to brittle fracture during screw fixation. This study addresses the challenge of tuning local toughness in the peri-screw region of brittle ceramic scaffolds. Inspired by the presence of voids in many load-bearing biological materials, we explored how micro-pores interact with cracks to modulate fracture toughness. A circular scaffold is considered, featuring a central hole to accommodate the screw and a notch to trigger fracture. The scaffold was analysed under radial compression, using finite element simulations based on a phase field formulation for brittle fracture. The influence of notch size on crack propagation was first investigated and compared with the behavior of a plate under mode I failure. Subsequently, the influence of micro-pore shape and spatial arrangement on strength and toughness was examined. Results showed that the circular scaffold attenuates notch sensitivity when compared to the plate-like scaffold, due to the interplay between circumferential tension and radial compression. Circular pores increased energy dissipation through crack deflection and they decreased the strength due to stress concentration. Elongated pores preserved strength by mitigating these stress peaks. These findings identify key geometric parameters for optimizing the mechanical reliability of ceramic scaffolds requiring screw fixation.
- 9 July 2026
- Published by MDPI AG in Biomimetics
- Vol. 11 (7) , 479
Open AccessStrategic Placement of Pores to Modulate Toughness in Hydroxyapatite Bone Scaffolds Fixation
Hydroxyapatite-based ceramic scaffolds are attractive for bone tissue engineering but are prone to brittle fracture during screw fixation. This study addresses the challenge of tuning local toughness in the peri-screw region of brittle ceramic scaffolds. Inspired by the presence of voids in many load-bearing biological materials, we explored how micro-pores interact with cracks to modulate fracture toughness. A circular scaffold is considered, featuring a central hole to accommodate the screw and a notch to trigger fracture. The scaffold was analysed under radial compression, using finite element simulations based on a phase field formulation for brittle fracture. The influence of notch size on crack propagation was first investigated and compared with the behavior of a plate under mode I failure. Subsequently, the influence of micro-pore shape and spatial arrangement on strength and toughness was examined. Results showed that the circular scaffold attenuates notch sensitivity when compared to the plate-like scaffold, due to the interplay between circumferential tension and radial compression. Circular pores increased energy dissipation through crack deflection and they decreased the strength due to stress concentration. Elongated pores preserved strength by mitigating these stress peaks. These findings identify key geometric parameters for optimizing the mechanical reliability of ceramic scaffolds requiring screw fixation.
- Open Access
- 16 March 2026
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (5) , 1775-1791
Design of 3D-printed hydroxyapatite intervertebral fusion cages in a patient specific framework
Fusion surgery involves replacing degenerated intervertebral discs with artificial implants, usually composed of titanium alloys or PEEK, requiring bone grafting to assist tissue growth. This study aims to evaluate numerically 3D-printed porous ceramic implants as a bioactive alternative. Clinical computed tomographies of an adult patient were used to reconstruct the geometry and to assign mechanical properties to L1 and L2 vertebrae, utilizing a patient-specific anisotropic micromechanics-based model. The influence of different microstructural choices on a porous hydroxyapatite-based scaffold was analysed through finite element analysis, simulating standing and flexion. The analyzed scaffolds included: microstructured Face Centered Cubic (FCC) and Kelvin-based devices with uniform porosity (75%), and a Voronoi microstructured scaffold with uniform (75%) and graded porosity (60% external, 90% internal). Homogenized models were considered as a potential strategy to reduce computational costs. The FCC geometry and graded Voronoi proved more mechanically resistant to failure. Homogenized mechanical properties simplified the model, but didn’t accurately represent microstructural behaviour and local mechanical failure couldn’t be suitably identified. Patient-specific models allowed for a more accurate representation of mechanical stresses, leading to a reduced risk of structural failure. Hydroxyapatite proves to be a promising material for 3D-printed lumbar interbody fusion cages, able to provide primary stability.
- 16 March 2026
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (5) , 1775-1791
Open AccessDesign of 3D-printed hydroxyapatite intervertebral fusion cages in a patient specific framework
Fusion surgery involves replacing degenerated intervertebral discs with artificial implants, usually composed of titanium alloys or PEEK, requiring bone grafting to assist tissue growth. This study aims to evaluate numerically 3D-printed porous ceramic implants as a bioactive alternative. Clinical computed tomographies of an adult patient were used to reconstruct the geometry and to assign mechanical properties to L1 and L2 vertebrae, utilizing a patient-specific anisotropic micromechanics-based model. The influence of different microstructural choices on a porous hydroxyapatite-based scaffold was analysed through finite element analysis, simulating standing and flexion. The analyzed scaffolds included: microstructured Face Centered Cubic (FCC) and Kelvin-based devices with uniform porosity (75%), and a Voronoi microstructured scaffold with uniform (75%) and graded porosity (60% external, 90% internal). Homogenized models were considered as a potential strategy to reduce computational costs. The FCC geometry and graded Voronoi proved more mechanically resistant to failure. Homogenized mechanical properties simplified the model, but didn’t accurately represent microstructural behaviour and local mechanical failure couldn’t be suitably identified. Patient-specific models allowed for a more accurate representation of mechanical stresses, leading to a reduced risk of structural failure. Hydroxyapatite proves to be a promising material for 3D-printed lumbar interbody fusion cages, able to provide primary stability.
- 8 July 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 26 (05)
IMAGE-BASED PATIENT-SPECIFIC MODELLING IN ORAL SURGERY
Accurate patient-specific modeling and finite element analysis are fundamental for achieving reliable results that can support pre-surgical planning, device design and biomechanical evaluation in oral surgery. This study presents a workflow for image-based patient-specific modeling applied to a guided bone regeneration clinical case. The workflow starts with image-based properties modeling, including bone density calibration, clinical image segmentation, and micro-mechanical bone modeling. Then, a custom device was designed, and a material was selected and its material properties were obtained through mechanical characterization. Lastly, a patient-specific finite element model was created with appropriate boundary conditions to evaluate the biomechanical behavior of the device and the bone state at interfaces with the device and screws. The work highlights the importance of bone density calibration and the modeling of anisotropic and nonhomogeneous bone properties in FEM to accurately evaluate the bone state after a guided bone regeneration surgery. This study has established a methodology for creating patient-specific models based on clinical imaging data in the context of oral surgery. This approach facilitates the biomechanical assessment of 3D-printed devices, as well as the interactions at the interfaces between device and bone, and screws and bone.
- 8 July 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 26 (05)
IMAGE-BASED PATIENT-SPECIFIC MODELLING IN ORAL SURGERY
Accurate patient-specific modeling and finite element analysis are fundamental for achieving reliable results that can support pre-surgical planning, device design and biomechanical evaluation in oral surgery. This study presents a workflow for image-based patient-specific modeling applied to a guided bone regeneration clinical case. The workflow starts with image-based properties modeling, including bone density calibration, clinical image segmentation, and micro-mechanical bone modeling. Then, a custom device was designed, and a material was selected and its material properties were obtained through mechanical characterization. Lastly, a patient-specific finite element model was created with appropriate boundary conditions to evaluate the biomechanical behavior of the device and the bone state at interfaces with the device and screws. The work highlights the importance of bone density calibration and the modeling of anisotropic and nonhomogeneous bone properties in FEM to accurately evaluate the bone state after a guided bone regeneration surgery. This study has established a methodology for creating patient-specific models based on clinical imaging data in the context of oral surgery. This approach facilitates the biomechanical assessment of 3D-printed devices, as well as the interactions at the interfaces between device and bone, and screws and bone.
- Open Access
- 31 January 2025
- Published by Elsevier in Acta Materialia
- Vol. 287
Elastic and failure characterization of hydroxyapatite TPMS scaffolds using a combined approach of ultrasound, compression tests and micro-CT based numerical models
- 31 January 2025
- Published by Elsevier in Acta Materialia
- Vol. 287
Open AccessElastic and failure characterization of hydroxyapatite TPMS scaffolds using a combined approach of ultrasound, compression tests and micro-CT based numerical models