Nishant Goswami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nishant Goswami has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Nishant Doshi
Pandit Deendayal Energy University
1 shared publication - Raju Mudhulkar
Department of Chemistry, Koneru Lakshmaiah Education Foundation, Bowrampet, Hyderabad-500043, Telangana, India
1 shared publication - Tarulata Chauhan
Gujarat Universisty
1 shared publication
Latest Publications
- Open Access
- 31 January 2025
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 37 (2) , 291-299
Quality by Design and Green Chemistry Analytical Method: New Combined Methodology for Quantification of Cyanocobalamin and Benzyl Alcohol in Parenteral Formulations
Developing methods for the analysis of hazardous chemicals and complex parenteral formulations is a challenging process. To address these challenges, the integration of green chemistry principles and design of experiments proves highly effective. This study introduces a novel approach that combines green analytical chemistry and design of experiments (DoE) to develop a sensitive, reproducible and stability indicating method by high-pressure liquid chromatography method for quantification of cyanocobalamin and benzyl alcohol in liquid parenteral formulations. A high-pressure liquid chromatography methodology for quantification of cyanocobalamin and benzyl alcohol was established with an analytical quality by design principle. The method employs the central composite response, which optimizes the connection between factors and responses with reduced number of design points and experimental runs, yielding statistically significant results and enhancing analytical quality. Separation of cyanocobalamin and benzyl alcohol was achieved on Zorbax C-8 column (250 * 4.6 mm with 5 µm) using buffer as ammonium formate (pH 2.5) and acetonitrile with a gradient mobile phase at a pump flow of 1.0 mL/min. Detection was performed by ultra violet detector set to a wavelength of 254 nm. The proposed method is validated in line with ICH Q2 (R2) guidelines, evaluating parameters such as linearity, accuracy, precision, system suitability, sensitivity, robustness and solution stability, all within acceptable ranges. The eco-affability and greenness of new developed method were checked by using the Analytical Greenness metric, Green Analytical Procedure Index and National Environmental Method Index, confirming its suitability as an environmentally sustainable analytical approach.
- 31 January 2025
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 37 (2) , 291-299
Open AccessQuality by Design and Green Chemistry Analytical Method: New Combined Methodology for Quantification of Cyanocobalamin and Benzyl Alcohol in Parenteral Formulations
Developing methods for the analysis of hazardous chemicals and complex parenteral formulations is a challenging process. To address these challenges, the integration of green chemistry principles and design of experiments proves highly effective. This study introduces a novel approach that combines green analytical chemistry and design of experiments (DoE) to develop a sensitive, reproducible and stability indicating method by high-pressure liquid chromatography method for quantification of cyanocobalamin and benzyl alcohol in liquid parenteral formulations. A high-pressure liquid chromatography methodology for quantification of cyanocobalamin and benzyl alcohol was established with an analytical quality by design principle. The method employs the central composite response, which optimizes the connection between factors and responses with reduced number of design points and experimental runs, yielding statistically significant results and enhancing analytical quality. Separation of cyanocobalamin and benzyl alcohol was achieved on Zorbax C-8 column (250 * 4.6 mm with 5 µm) using buffer as ammonium formate (pH 2.5) and acetonitrile with a gradient mobile phase at a pump flow of 1.0 mL/min. Detection was performed by ultra violet detector set to a wavelength of 254 nm. The proposed method is validated in line with ICH Q2 (R2) guidelines, evaluating parameters such as linearity, accuracy, precision, system suitability, sensitivity, robustness and solution stability, all within acceptable ranges. The eco-affability and greenness of new developed method were checked by using the Analytical Greenness metric, Green Analytical Procedure Index and National Environmental Method Index, confirming its suitability as an environmentally sustainable analytical approach.
- 1 January 2012
- Published by Springer Nature
- p. 239-244
Efficient Cryptography Technique on Perturbed Data in Distributed Environment
- 1 January 2012
- Published by Springer Nature
- p. 239-244
Efficient Cryptography Technique on Perturbed Data in Distributed Environment