Jacqueline Dister
Research Subjects
Jacqueline Dister has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Craig H. Mermel
Google Health, Palo Alto, USA
2 shared publications - Abbey Sawyer
Icahn School of Medicine at Mount Sinai
1 shared publication Adam Poole
Precision Neuroscience Corporation
1 shared publication- Alexandra Fink Skular
Icahn School of Medicine at Mount Sinai
1 shared publication - Benjamin I. Rapoport
Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, Mount Sinai Hospital, New York, New York, USA
1 shared publication Benjamin Rapoport
Precision Neuroscience Corporation
1 shared publication
Latest Publications
- Open Access
- 1 October 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (5) , 056055
Ultra high-density, 4096-channel intraoperative neurophysiological brain mapping for functional localization of the human central sulcus
Objective. Intraoperative localization of the central sulcus (CS) using somatosensory evoked-potential (SSEP) phase reversal (PR) is routinely performed with sparse subdural strip electrodes. We evaluated whether a multi-array, 4096-channel surface micro-electrocorticography ( μ ECoG) configuration could provide dense two-dimensional sampling of stimulus-dependent sensorimotor responses within a standard neurosurgical workflow. Approach. Four Precision Neuroscience Layer 7 μ ECoG arrays (1024 platinum electrodes per array on a flexible polyimide substrate, 400 μ m electrode pitch, ∼1.5 cm 2 active area per array) were deployed during resection of a right parafalcine meningioma in a 56-year-old male. Two arrays were placed horizontally on the exposed precentral gyrus; two were inserted under the intact dura overlying the postcentral gyrus, using a custom flexible stylet. Somatosensory evoked potentials (SSEPs) were recorded across five contralateral stimulation conditions (median nerve, ulnar nerve, index finger, middle finger, ring finger). Per-electrode SSEP responses were classified without anatomical labels, and spatial organization was quantified across stimulation conditions. Stimulus-locked high-gamma activity, digit-response maps, and signal quality across micro- and macroelectrodes were also evaluated. Main results. Aggregate channel yield was 91.3% (3739/4096) at a 2 MΩ impedance criterion (per-array range 86.7%–97.0%). Per-electrode amplitude maps resolved continuous phase-reversal contours with stimulus-specific spatial structure; reversal latencies were 19, 21, 25, 26, and 25 ms for median, ulnar, index, middle, and ring stimulation respectively. PR occurred within a single array in eight of ten sensory-array recordings, with the phase-reversal pattern varying across stimulation conditions. Digit responses showed measurable spatial differentiation within substantially overlapping response fields. Automated classification of the phase-reversal responses recovered the expected motor and sensory organization, consistent with the standard-of-care intraoperative localization performed in the same case. Significance. The deployment shows that a four-array Layer 7 μ ECoG configuration can be used within a standard neurosurgical exposure and provides dense two-dimensional sampling of stimulus-dependent phase-reversal patterns across the peri-Rolandic recording field. The measured responses were correlated across approximately 3–4 mm of cortex, an order of magnitude coarser than the 400 μ m electrode pitch, so the contribution demonstrated here is dense spatial sampling rather than submillimeter physiological resolution. Dense sampling rendered the polarity transition as a continuous two-dimensional boundary across the recording field rather than as a reversal between two adjacent contacts. The platform supports future evaluation of high-density surface μ ECoG for intraoperative mapping and chronic brain–computer interface applications.
- 1 October 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (5) , 056055
Open AccessUltra high-density, 4096-channel intraoperative neurophysiological brain mapping for functional localization of the human central sulcus
Objective. Intraoperative localization of the central sulcus (CS) using somatosensory evoked-potential (SSEP) phase reversal (PR) is routinely performed with sparse subdural strip electrodes. We evaluated whether a multi-array, 4096-channel surface micro-electrocorticography ( μ ECoG) configuration could provide dense two-dimensional sampling of stimulus-dependent sensorimotor responses within a standard neurosurgical workflow. Approach. Four Precision Neuroscience Layer 7 μ ECoG arrays (1024 platinum electrodes per array on a flexible polyimide substrate, 400 μ m electrode pitch, ∼1.5 cm 2 active area per array) were deployed during resection of a right parafalcine meningioma in a 56-year-old male. Two arrays were placed horizontally on the exposed precentral gyrus; two were inserted under the intact dura overlying the postcentral gyrus, using a custom flexible stylet. Somatosensory evoked potentials (SSEPs) were recorded across five contralateral stimulation conditions (median nerve, ulnar nerve, index finger, middle finger, ring finger). Per-electrode SSEP responses were classified without anatomical labels, and spatial organization was quantified across stimulation conditions. Stimulus-locked high-gamma activity, digit-response maps, and signal quality across micro- and macroelectrodes were also evaluated. Main results. Aggregate channel yield was 91.3% (3739/4096) at a 2 MΩ impedance criterion (per-array range 86.7%–97.0%). Per-electrode amplitude maps resolved continuous phase-reversal contours with stimulus-specific spatial structure; reversal latencies were 19, 21, 25, 26, and 25 ms for median, ulnar, index, middle, and ring stimulation respectively. PR occurred within a single array in eight of ten sensory-array recordings, with the phase-reversal pattern varying across stimulation conditions. Digit responses showed measurable spatial differentiation within substantially overlapping response fields. Automated classification of the phase-reversal responses recovered the expected motor and sensory organization, consistent with the standard-of-care intraoperative localization performed in the same case. Significance. The deployment shows that a four-array Layer 7 μ ECoG configuration can be used within a standard neurosurgical exposure and provides dense two-dimensional sampling of stimulus-dependent phase-reversal patterns across the peri-Rolandic recording field. The measured responses were correlated across approximately 3–4 mm of cortex, an order of magnitude coarser than the 400 μ m electrode pitch, so the contribution demonstrated here is dense spatial sampling rather than submillimeter physiological resolution. Dense sampling rendered the polarity transition as a continuous two-dimensional boundary across the recording field rather than as a reversal between two adjacent contacts. The platform supports future evaluation of high-density surface μ ECoG for intraoperative mapping and chronic brain–computer interface applications.
- Open Access
- 11 September 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (5) , 053002
Brain–computer interface clinical trial design considerations and clinical outcome assessments in pivotal studies: a summary of the 11th BCI society meeting 2025 workshop
Objective. The Brain Computer Interface (BCI) Society Meeting 2025 held a workshop in collaboration with the Implantable BCI Collaborative Community (iBCI-CC) to discuss the selection, development and validation of clinical trial outcome assessments (COAs) for pivotal studies of BCIs. The iBCI-CC Clinical Study Endpoints Workgroup aims to build consensus on a COA framework that can meet the demands of emerging iBCI trials. Approach. The workshop brought together diverse stakeholders from the iBCI-CC community and beyond, including industry, academic and government institutions to engage in pre-competitive collaborative discussion. Main results. Through presentations, panel discussions and breakout groups, workshop participants highlighted meaningful aspects of health (MAHs) relevant to iBCI users, clarified the need to define corresponding concepts of interest (COIs) and to identify or adapt COAs capable of capturing both functional impact and real-world use. Key challenges highlighted during the workshop are patient heterogeneity, the lack of widely validated and fit-for-purpose COAs, and the need to capture meaningful outcomes in home and daily-life environments. Lessons drawn from trials such as ADAPT-PD underscore the value of capturing device performance in home and daily-life settings, highlighting the need for context-sensitive and flexible metrics that reflect patient priorities. Significance. This workshop lays a foundation for the iBCI-CC Clinical Study Endpoints Workgroup to establish a transparent process for identifying MAHs and COIs that are suitable for specific iBCI technologies, patient-informed, and conducive to regulatory approval and reimbursement. By combining rigorous, quantitative assessment with patient-informed goals, iBCI clinical trials can advance toward safe, effective, and accessible neurotechnologies that enhance how a person with a severe motor impairment feels, functions and survives.
- 11 September 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (5) , 053002
Open AccessBrain–computer interface clinical trial design considerations and clinical outcome assessments in pivotal studies: a summary of the 11th BCI society meeting 2025 workshop
Objective. The Brain Computer Interface (BCI) Society Meeting 2025 held a workshop in collaboration with the Implantable BCI Collaborative Community (iBCI-CC) to discuss the selection, development and validation of clinical trial outcome assessments (COAs) for pivotal studies of BCIs. The iBCI-CC Clinical Study Endpoints Workgroup aims to build consensus on a COA framework that can meet the demands of emerging iBCI trials. Approach. The workshop brought together diverse stakeholders from the iBCI-CC community and beyond, including industry, academic and government institutions to engage in pre-competitive collaborative discussion. Main results. Through presentations, panel discussions and breakout groups, workshop participants highlighted meaningful aspects of health (MAHs) relevant to iBCI users, clarified the need to define corresponding concepts of interest (COIs) and to identify or adapt COAs capable of capturing both functional impact and real-world use. Key challenges highlighted during the workshop are patient heterogeneity, the lack of widely validated and fit-for-purpose COAs, and the need to capture meaningful outcomes in home and daily-life environments. Lessons drawn from trials such as ADAPT-PD underscore the value of capturing device performance in home and daily-life settings, highlighting the need for context-sensitive and flexible metrics that reflect patient priorities. Significance. This workshop lays a foundation for the iBCI-CC Clinical Study Endpoints Workgroup to establish a transparent process for identifying MAHs and COIs that are suitable for specific iBCI technologies, patient-informed, and conducive to regulatory approval and reimbursement. By combining rigorous, quantitative assessment with patient-informed goals, iBCI clinical trials can advance toward safe, effective, and accessible neurotechnologies that enhance how a person with a severe motor impairment feels, functions and survives.
- Open Access
- 7 March 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (2) , 026009
First-in-human experience performing high-resolution cortical mapping using a novel microelectrode array containing 1024 electrodes
Objective. Localization of function within the brain and central nervous system is an essential aspect of clinical neuroscience. Classical descriptions of functional neuroanatomy provide a foundation for understanding the functional significance of identifiable anatomic structures. However, individuals exhibit substantial variation, particularly in the presence of disorders that alter tissue structure or impact function. Furthermore, functional regions do not always correspond to identifiable structural features. Understanding function at the level of individual patients—and diagnosing and treating such patients—often requires techniques capable of correlating neural activity with cognition, behavior, and experience in anatomically precise ways. Approach. Recent advances in brain–computer interface technology have given rise to a new generation of electrophysiologic tools for scalable, nondestructive functional mapping with spatial precision in the range of tens to hundreds of micrometers, and temporal resolutions in the range of tens to hundreds of microseconds. Here we describe our initial intraoperative experience with novel, thin-film arrays containing 1024 surface microelectrodes for electrocorticographic mapping in a first-in-human study. Main results. Eight patients undergoing standard electrophysiologic cortical mapping during resection of eloquent-region brain tumors consented to brief sessions of concurrent mapping (micro-electrocorticography) using the novel arrays. Four patients underwent motor mapping using somatosensory evoked potentials (SSEPs) while under general anesthesia, and four underwent awake language mapping, using both standard paradigms and the novel microelectrode array. SSEP phase reversal was identified in the region predicted by conventional mapping, but at higher resolution (0.4 mm) and as a contour rather than as a point. In Broca’s area (confirmed by direct cortical stimulation), speech planning was apparent in the micro-electrocorticogram as high-amplitude beta-band activity immediately prior to the articulatory event. Significance. These findings support the feasibility and potential clinical utility of incorporating micro-electrocorticography into the intraoperative workflow for systematic cortical mapping of functional brain regions.
- 7 March 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (2) , 026009
Open AccessFirst-in-human experience performing high-resolution cortical mapping using a novel microelectrode array containing 1024 electrodes
Objective. Localization of function within the brain and central nervous system is an essential aspect of clinical neuroscience. Classical descriptions of functional neuroanatomy provide a foundation for understanding the functional significance of identifiable anatomic structures. However, individuals exhibit substantial variation, particularly in the presence of disorders that alter tissue structure or impact function. Furthermore, functional regions do not always correspond to identifiable structural features. Understanding function at the level of individual patients—and diagnosing and treating such patients—often requires techniques capable of correlating neural activity with cognition, behavior, and experience in anatomically precise ways. Approach. Recent advances in brain–computer interface technology have given rise to a new generation of electrophysiologic tools for scalable, nondestructive functional mapping with spatial precision in the range of tens to hundreds of micrometers, and temporal resolutions in the range of tens to hundreds of microseconds. Here we describe our initial intraoperative experience with novel, thin-film arrays containing 1024 surface microelectrodes for electrocorticographic mapping in a first-in-human study. Main results. Eight patients undergoing standard electrophysiologic cortical mapping during resection of eloquent-region brain tumors consented to brief sessions of concurrent mapping (micro-electrocorticography) using the novel arrays. Four patients underwent motor mapping using somatosensory evoked potentials (SSEPs) while under general anesthesia, and four underwent awake language mapping, using both standard paradigms and the novel microelectrode array. SSEP phase reversal was identified in the region predicted by conventional mapping, but at higher resolution (0.4 mm) and as a contour rather than as a point. In Broca’s area (confirmed by direct cortical stimulation), speech planning was apparent in the micro-electrocorticogram as high-amplitude beta-band activity immediately prior to the articulatory event. Significance. These findings support the feasibility and potential clinical utility of incorporating micro-electrocorticography into the intraoperative workflow for systematic cortical mapping of functional brain regions.