Yves Bernard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yves Bernard has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Adel Razek
Laboratoire de Génie Electrique et Electronique de Paris
4 shared publications F. Lefaucheux
Laboratoire de Minéralogie-Cristallographie, Associé au CNRS et aux Universités Paris 6 & 7, 4 Place Jussieu, F-75252 Paris Cedex 05, France
2 shared publicationsArup Kumar Nandi
1 shared publication- Brahim Mezghani
University of Sfax
1 shared publication Camilo Hernandez
Laboratoire de Génie Electrique de Paris (LGEP)/SPEE-Labs, CNRS UMR 8507, Supélec, Université Pierre et Marie Curie Paris VI, Université Paris-Sud 11, Gif sur Yvette, France
1 shared publication- Christian P. Robert
CEREMADE, CNRS, Université Paris-Dauphine, Université PSL, Paris, France
1 shared publication
Latest Publications
- Open Access
- 1 February 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (3) , 035537
Experimental and theoretical investigation of shear-stress-induced energy harvesting using a piezoelectric element coupled to viscoelastic media
This work investigates the generation of electrical energy from a piezoelectric material predominantly loaded in shear. A small, constant normal preload is maintained solely to guarantee stable contact, as pure shear cannot be produced in its absence. An experimental setup was designed applying moderate normal pressure systematically to an NCE40 piezoelectric element that was coupled with five different polymeric foams, each tested under oscillatory shear at 1, 3, and 7 Hz, under two normal-pressure regimes: a low preload P0 = 2000 Pa, and a higher preload to enhance interfacial coupling P1 = 8000 Pa. The results demonstrated that the foam stiffness and interfacial pressure play a crucial role in energy conversion as does the excitation frequency used in the experiment. Among the three frequencies tested (1, 3 ,7 Hz), 7 Hz produced the highest energy output, yielding peak-to-peak voltages ranging from 23 to 143 mV. To interpret the experimental data, an analytical model based on Bleustein–Gulyaev (B–G) shear waves in viscoelastic media was employed, incorporating both Maxwell and Kelvin–Voigt rheological representations. The dimensionless analysis—through the Womersley number ( α ), Deborah number ( D e ), electromechanical coupling factor ( β ), and charge–discharge parameter ( σ )—enabled the comparison between theoretical predictions and experimental trends. The Kelvin–Voigt model, describing elastic solids with moderate viscous damping, exhibited better agreement with the experimental voltages, while the Maxwell model captured the behavior of more deformable foams. Theoretical results ( ϕ a , pp = 112.7672 mV, ϕ b , pp = 88.64 mV) were consistent with the measured range, confirming that shear-induced piezoelectric generation can be effectively modeled using a viscoelastic–piezoelectric coupling framework. These findings validate shear-based energy harvesting as a viable low-frequency mechanism. The approach provides a foundation for the design of compact, self-powered devices and sensors that exploit mechanical shear interactions in viscoelastic materials.
- 1 February 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (3) , 035537
Open AccessExperimental and theoretical investigation of shear-stress-induced energy harvesting using a piezoelectric element coupled to viscoelastic media
This work investigates the generation of electrical energy from a piezoelectric material predominantly loaded in shear. A small, constant normal preload is maintained solely to guarantee stable contact, as pure shear cannot be produced in its absence. An experimental setup was designed applying moderate normal pressure systematically to an NCE40 piezoelectric element that was coupled with five different polymeric foams, each tested under oscillatory shear at 1, 3, and 7 Hz, under two normal-pressure regimes: a low preload P0 = 2000 Pa, and a higher preload to enhance interfacial coupling P1 = 8000 Pa. The results demonstrated that the foam stiffness and interfacial pressure play a crucial role in energy conversion as does the excitation frequency used in the experiment. Among the three frequencies tested (1, 3 ,7 Hz), 7 Hz produced the highest energy output, yielding peak-to-peak voltages ranging from 23 to 143 mV. To interpret the experimental data, an analytical model based on Bleustein–Gulyaev (B–G) shear waves in viscoelastic media was employed, incorporating both Maxwell and Kelvin–Voigt rheological representations. The dimensionless analysis—through the Womersley number ( α ), Deborah number ( D e ), electromechanical coupling factor ( β ), and charge–discharge parameter ( σ )—enabled the comparison between theoretical predictions and experimental trends. The Kelvin–Voigt model, describing elastic solids with moderate viscous damping, exhibited better agreement with the experimental voltages, while the Maxwell model captured the behavior of more deformable foams. Theoretical results ( ϕ a , pp = 112.7672 mV, ϕ b , pp = 88.64 mV) were consistent with the measured range, confirming that shear-induced piezoelectric generation can be effectively modeled using a viscoelastic–piezoelectric coupling framework. These findings validate shear-based energy harvesting as a viable low-frequency mechanism. The approach provides a foundation for the design of compact, self-powered devices and sensors that exploit mechanical shear interactions in viscoelastic materials.
- Open Access
Potential of Piezoelectric Actuation and Sensing in High Reliability Precision Mechanisms and Their Applications in Medical Therapeutics
The present contribution aims to analyze and highlight the potential of piezoelectric materials in actuation and sensing duties, obtaining reliable high-precision outcomes in cutting-edge applications including medical interventions. This involves high-precision actuations of robotized procedures, as well as monitoring and controlling various physical phenomena via structural sensing. The characteristics of these applications offer enhanced precision machinery and robotic tools, medical robotic precise interventions, and high-accuracy structural sensing. The paper exposed, analyzed, reviewed and discussed different subjects related to piezoelectric actuators, involving their displacement and positioning strategies, piezoelectric sensors, medical applications of piezoelectric actuators and sensors, including robotic actuation for medical interventions, and structural sensing in the monitoring of wearable healthcare tools. Discussions among others on the advantages and limitations of piezoelectric sensors and actuators in general, as well as future research perspectives in medical involvements, are also presented at the end of the article. The specific features in the illustrated applications reflect crucial behaviors in robotic actuation for medical interventions, structural sensing in the monitoring of healthcare wearable tools, and the control of various structural physical occurrences.
Open AccessPotential of Piezoelectric Actuation and Sensing in High Reliability Precision Mechanisms and Their Applications in Medical Therapeutics
The present contribution aims to analyze and highlight the potential of piezoelectric materials in actuation and sensing duties, obtaining reliable high-precision outcomes in cutting-edge applications including medical interventions. This involves high-precision actuations of robotized procedures, as well as monitoring and controlling various physical phenomena via structural sensing. The characteristics of these applications offer enhanced precision machinery and robotic tools, medical robotic precise interventions, and high-accuracy structural sensing. The paper exposed, analyzed, reviewed and discussed different subjects related to piezoelectric actuators, involving their displacement and positioning strategies, piezoelectric sensors, medical applications of piezoelectric actuators and sensors, including robotic actuation for medical interventions, and structural sensing in the monitoring of wearable healthcare tools. Discussions among others on the advantages and limitations of piezoelectric sensors and actuators in general, as well as future research perspectives in medical involvements, are also presented at the end of the article. The specific features in the illustrated applications reflect crucial behaviors in robotic actuation for medical interventions, structural sensing in the monitoring of healthcare wearable tools, and the control of various structural physical occurrences.
- Open Access
- 2 October 2025
- Published by MDPI AG in Preprints.org
Potential of Piezoelectric Actuation and Sensing in High Reliability Precision Mechanisms and Their Applications in Medical Therapeutics
The present contribution aims to analyze and highlight the potential of piezoelectric materials in actuation and sensing duties performing reliable high precision outcomes in cutting-edge applications including medical involvements. These engage high precision, actuations of robotized procedures as well as monitoring and controlling various physical phenomena via structural sensing. The characteristics of these applications project en-hanced, precision machinery and robotic tools, medical robotic precise interventions and high accuracy structural sensing. The paper exposed, analyzed, reviewed and discussed different subjects related to piezoelectric actuators involving their displacement and posi-tioning strategies, piezoelectric sensors, medical applications of piezoelectric actuators and sensors including robotic actuation for medical interventions, structural sensing in monitoring of healthcare wearable tools. Discussions among others on the advantages and limitations of piezoelectric sensors and actuators in general as well as future research perspectives in medical involvements, are also presented at the end of the article. The spe-cific features in the illustrated applications reflect crucial behaviors in robotic actuation for medical interventions, structural sensing in monitoring of healthcare wearable tools, and control of various structural physical occurrences.
- 2 October 2025
- Published by MDPI AG in Preprints.org
Open AccessPotential of Piezoelectric Actuation and Sensing in High Reliability Precision Mechanisms and Their Applications in Medical Therapeutics
The present contribution aims to analyze and highlight the potential of piezoelectric materials in actuation and sensing duties performing reliable high precision outcomes in cutting-edge applications including medical involvements. These engage high precision, actuations of robotized procedures as well as monitoring and controlling various physical phenomena via structural sensing. The characteristics of these applications project en-hanced, precision machinery and robotic tools, medical robotic precise interventions and high accuracy structural sensing. The paper exposed, analyzed, reviewed and discussed different subjects related to piezoelectric actuators involving their displacement and posi-tioning strategies, piezoelectric sensors, medical applications of piezoelectric actuators and sensors including robotic actuation for medical interventions, structural sensing in monitoring of healthcare wearable tools. Discussions among others on the advantages and limitations of piezoelectric sensors and actuators in general as well as future research perspectives in medical involvements, are also presented at the end of the article. The spe-cific features in the illustrated applications reflect crucial behaviors in robotic actuation for medical interventions, structural sensing in monitoring of healthcare wearable tools, and control of various structural physical occurrences.
- 3 February 2025
- Published by Elsevier in Precision Engineering
- Vol. 93, 481-496
Development of a novel self-locking-at-rest piezoelectric inchworm motor with high switching frequency driving ability
- 3 February 2025
- Published by Elsevier in Precision Engineering
- Vol. 93, 481-496
Development of a novel self-locking-at-rest piezoelectric inchworm motor with high switching frequency driving ability
- 9 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 23 (1) , 242-251
2-D Traveling Wave Driven Piezoelectric Plate Robot for Planar Motion
In this paper, a concept design of a novel Traveling Wave Driven Piezoelectric Plate Robot (TWDPPR) for planar motion is presented. The TWDPPR consists of an aluminium plate structure, with four non-collocated piezoelectric patches bonded on its surface. A two dimensions modeling of non-collocated piezoelectric patches bonded on thin structures developed and validated in previous work is used in this paper to model the TWDPPR based on the “two modes excitation” method for propulsion. A preliminary design is presented and the model is then used to verify the generation of the 2D traveling wave on the plate for planar motion. A prototype is fabricated and a forward, backward, & steering motions are experimentally achieved. An experimental characterization of the TWDPPR is given in this paper.
- 9 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 23 (1) , 242-251
2-D Traveling Wave Driven Piezoelectric Plate Robot for Planar Motion
In this paper, a concept design of a novel Traveling Wave Driven Piezoelectric Plate Robot (TWDPPR) for planar motion is presented. The TWDPPR consists of an aluminium plate structure, with four non-collocated piezoelectric patches bonded on its surface. A two dimensions modeling of non-collocated piezoelectric patches bonded on thin structures developed and validated in previous work is used in this paper to model the TWDPPR based on the “two modes excitation” method for propulsion. A preliminary design is presented and the model is then used to verify the generation of the 2D traveling wave on the plate for planar motion. A prototype is fabricated and a forward, backward, & steering motions are experimentally achieved. An experimental characterization of the TWDPPR is given in this paper.
- 13 April 2017
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 26 (5) , 055012
Static force transducer based on resonant piezoelectric structure: root cause investigation
The aim of this paper is to investigate the design and the integration of a static force sensor based on a resonant bulk acoustic wave piezoelectric transducer. Experimental measurements of the electrical admittance spectrum show its dependence on the applied force. We noticed that the quality of the frequency response for a given vibration mode degrades with the increase of the applied force, which limits the force measuring range. The root cause of the response-stress dependence is investigated by means of the developed analytical model and a finite element analysis. The analysis results show that the selected operating vibration mode, the components of the structure on which the piezoelectric specimen is positioned and the boundary conditions at the contact interfaces between all the components have a direct effect on the electrical admittance spectrum. A modified structure was proposed to enhance the quality of the frequency response. The experimental tests show higher measuring range (up to 1500 N).
- 13 April 2017
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 26 (5) , 055012
Static force transducer based on resonant piezoelectric structure: root cause investigation
The aim of this paper is to investigate the design and the integration of a static force sensor based on a resonant bulk acoustic wave piezoelectric transducer. Experimental measurements of the electrical admittance spectrum show its dependence on the applied force. We noticed that the quality of the frequency response for a given vibration mode degrades with the increase of the applied force, which limits the force measuring range. The root cause of the response-stress dependence is investigated by means of the developed analytical model and a finite element analysis. The analysis results show that the selected operating vibration mode, the components of the structure on which the piezoelectric specimen is positioned and the boundary conditions at the contact interfaces between all the components have a direct effect on the electrical admittance spectrum. A modified structure was proposed to enhance the quality of the frequency response. The experimental tests show higher measuring range (up to 1500 N).
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 290-295
Macro model analysis of a single mass 6-DOF Inertial Measurement Unit system
In this paper, a preliminary analysis of a 6-axis micromachined Inertial Measurement Unit (IMU) structure is performed. We firstly give a review of current approaches found in literature for 6-axis IMU sensor technology. Then, we present and analyze the proposed single mass macro model structure. We mainly investigate the simultaneous detection of all possible six axis motion components with a single bloc based on SMSD approach. The angular velocity detection method is based on the Coriolis Effect which requires a certain translation applied to a suspended mass attached to a piezoelectric membrane. Two methods have been examined: first one is based on the Eigenfrequencies of the membrane, and second one is based on the inverse piezoelectric effect to actuate the membrane. So, electrodes deposited on the piezoelectric membrane are employed for sensing and actuating mechanisms based on direct/reverse piezoelectric effects. As a primary investigation, a modal analysis of the IMU macro model consisting of a piezoelectric Buzzer is presented. FEM simulations and measurement values show a good agreement. Applied stress on the membrane submitted to a linear acceleration is evaluated and improved designs, allowing 3 to 4 times higher stress values, are investigated.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 290-295
Macro model analysis of a single mass 6-DOF Inertial Measurement Unit system
In this paper, a preliminary analysis of a 6-axis micromachined Inertial Measurement Unit (IMU) structure is performed. We firstly give a review of current approaches found in literature for 6-axis IMU sensor technology. Then, we present and analyze the proposed single mass macro model structure. We mainly investigate the simultaneous detection of all possible six axis motion components with a single bloc based on SMSD approach. The angular velocity detection method is based on the Coriolis Effect which requires a certain translation applied to a suspended mass attached to a piezoelectric membrane. Two methods have been examined: first one is based on the Eigenfrequencies of the membrane, and second one is based on the inverse piezoelectric effect to actuate the membrane. So, electrodes deposited on the piezoelectric membrane are employed for sensing and actuating mechanisms based on direct/reverse piezoelectric effects. As a primary investigation, a modal analysis of the IMU macro model consisting of a piezoelectric Buzzer is presented. FEM simulations and measurement values show a good agreement. Applied stress on the membrane submitted to a linear acceleration is evaluated and improved designs, allowing 3 to 4 times higher stress values, are investigated.
- 3 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 60 (9) , 1949-1956
Design and manufacturing of a piezoelectric traveling-wave pumping device
In this article, we present the design and construction of a micropump exhibiting a nontraditional pumping principle whose design is achievable at very low scales. The operation is based on the action of a mechanical traveling wave deforming the bottom wall of a flexible channel containing a fluid. The paper treats for the first time the influence of the traveling wave parameters on the performance of the pump with the help of finite element simulations. The results obtained from the simulation are subsequently used for the dimensioning of the linear ultrasonic traveling wave actuator that drives the device. Finally, a very simple channel-reservoirs structure was conceived to test the device. At this point, several measurements of flow rate and back pressure were carried out to estimate the performance of the prototype for different values of wave amplitude. The article finishes with a comparison between the numerical and experimental results and a brief section of discussion and conclusions.
- 3 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 60 (9) , 1949-1956
Design and manufacturing of a piezoelectric traveling-wave pumping device
In this article, we present the design and construction of a micropump exhibiting a nontraditional pumping principle whose design is achievable at very low scales. The operation is based on the action of a mechanical traveling wave deforming the bottom wall of a flexible channel containing a fluid. The paper treats for the first time the influence of the traveling wave parameters on the performance of the pump with the help of finite element simulations. The results obtained from the simulation are subsequently used for the dimensioning of the linear ultrasonic traveling wave actuator that drives the device. Finally, a very simple channel-reservoirs structure was conceived to test the device. At this point, several measurements of flow rate and back pressure were carried out to estimate the performance of the prototype for different values of wave amplitude. The article finishes with a comparison between the numerical and experimental results and a brief section of discussion and conclusions.
- 1 October 1996
- Published by Elsevier in Journal of Crystal Growth
- Vol. 168 (1-4) , 40-43
Time evolution of refractive index of gelled and gel-free supersaturated lysozyme solutions
- 1 October 1996
- Published by Elsevier in Journal of Crystal Growth
- Vol. 168 (1-4) , 40-43
Time evolution of refractive index of gelled and gel-free supersaturated lysozyme solutions
- 1 July 1994
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 50 (4) , 496-503
Study of nucleation-related phenomena in lysozyme solutions. Application to gel growth
Two populations of aggregates are generally indentified in supersaturated solutions of biological macromolecules: small aggregates of a size which is less than 5 nm and large aggregates, the largest of which are at least one order of magnitude bigger. In order to understand the role played by the microporous network of a gel in the growth and behaviour of these different species in the prenucleation period, an in situ observation of nucleation has been carried out using either free solutions or solutions trapped in agarose gels. In a previous study, free solutions were investigated by small-angle neutron scattering (SANS) to identify the small aggregates. Optical observations, made under the same conditions, revealed the formation of an amorphous precipitate which disappeared at the end of the experiment. The sedimentation of this phase, which occurs in free solution but never occurs in gelled solution, depletes the solution bulk and this could explain why the nucleation density is higher in agarose gel than in free solution. The case of silica gel, the behaviour of which is completely different with respect to nucleation, will be discussed.
- 1 July 1994
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 50 (4) , 496-503
Study of nucleation-related phenomena in lysozyme solutions. Application to gel growth
Two populations of aggregates are generally indentified in supersaturated solutions of biological macromolecules: small aggregates of a size which is less than 5 nm and large aggregates, the largest of which are at least one order of magnitude bigger. In order to understand the role played by the microporous network of a gel in the growth and behaviour of these different species in the prenucleation period, an in situ observation of nucleation has been carried out using either free solutions or solutions trapped in agarose gels. In a previous study, free solutions were investigated by small-angle neutron scattering (SANS) to identify the small aggregates. Optical observations, made under the same conditions, revealed the formation of an amorphous precipitate which disappeared at the end of the experiment. The sedimentation of this phase, which occurs in free solution but never occurs in gelled solution, depletes the solution bulk and this could explain why the nucleation density is higher in agarose gel than in free solution. The case of silica gel, the behaviour of which is completely different with respect to nucleation, will be discussed.