Yeseul Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yeseul Kang has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Eun-Kyung Kim
Department of Radiology, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Korea
2 shared publications - Hyun Joo Shin
Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Korea
2 shared publications - Keemin Sohn
Department of Urban Engineering, Chung-Ang University, Seoul, Korea
2 shared publications - Sejin Jeong
Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Korea
2 shared publications - Seungyun Jeong
Department of Smart City, Chung–Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul 156-756, Republic of Korea
2 shared publications - Changho Han
Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Seoul, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 1 March 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (2) , 129-140
Additive predictive value of preoperative thyroid ultrasound parameters for postoperative hypothyroidism after hemithyroidectomy: a single-center retrospective study
Purpose: This study was performed to examine the association between preoperative thyroid ultrasound (US) features and the risk of developing hypothyroidism after hemithyroidectomy.Methods: Patients who underwent hemithyroidectomy between March 2020 and June 2023 were retrospectively included. Postoperative hypothyroidism was defined as a continued need for thyroxine 2 years after surgery. To assess US features suggestive of diffuse thyroid disease, two radiologists evaluated the echogenicity, echotexture, and vascularity of the thyroid parenchyma on preoperative thyroid US images. A US thyroid parenchymal score was defined by summing the scores for these parameters, and a weighted score was also developed using β-coefficients from a multivariable logistic regression model. Model performance was evaluated using the area under the receiver operating characteristic curve (AUC) and integrated discrimination improvement (IDI).Results: Overall, 398 patients were included, of whom 191 (47.9%) developed postoperative hypothyroidism. Preoperative thyroid-stimulating hormone (TSH), body surface area-adjusted remnant thyroid volume, histologic evidence of thyroiditis, and both unweighted and weighted US thyroid parenchymal scores were identified as significant predictors of postoperative hypothyroidism. The unweighted and weighted US scores were statistically significant predictors in the multivariable analysis (unweighted: odds ratio [OR], 1.36 [95% confidence interval (CI), 1.04 to 1.78]; weighted: OR, 3.05 [95% CI, 1.22 to 7.62]). Although adding US scores did not significantly improve the AUC, it led to significant improvements in IDI (P=0.04 and P=0.03, respectively). Conclusion: US assessment of the thyroid parenchyma served as an independent predictor of postoperative hypothyroidism and improved discrimination of predicted probabilities based on preoperative TSH.
- 1 March 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (2) , 129-140
Open AccessAdditive predictive value of preoperative thyroid ultrasound parameters for postoperative hypothyroidism after hemithyroidectomy: a single-center retrospective study
Purpose: This study was performed to examine the association between preoperative thyroid ultrasound (US) features and the risk of developing hypothyroidism after hemithyroidectomy.Methods: Patients who underwent hemithyroidectomy between March 2020 and June 2023 were retrospectively included. Postoperative hypothyroidism was defined as a continued need for thyroxine 2 years after surgery. To assess US features suggestive of diffuse thyroid disease, two radiologists evaluated the echogenicity, echotexture, and vascularity of the thyroid parenchyma on preoperative thyroid US images. A US thyroid parenchymal score was defined by summing the scores for these parameters, and a weighted score was also developed using β-coefficients from a multivariable logistic regression model. Model performance was evaluated using the area under the receiver operating characteristic curve (AUC) and integrated discrimination improvement (IDI).Results: Overall, 398 patients were included, of whom 191 (47.9%) developed postoperative hypothyroidism. Preoperative thyroid-stimulating hormone (TSH), body surface area-adjusted remnant thyroid volume, histologic evidence of thyroiditis, and both unweighted and weighted US thyroid parenchymal scores were identified as significant predictors of postoperative hypothyroidism. The unweighted and weighted US scores were statistically significant predictors in the multivariable analysis (unweighted: odds ratio [OR], 1.36 [95% confidence interval (CI), 1.04 to 1.78]; weighted: OR, 3.05 [95% CI, 1.22 to 7.62]). Although adding US scores did not significantly improve the AUC, it led to significant improvements in IDI (P=0.04 and P=0.03, respectively). Conclusion: US assessment of the thyroid parenchyma served as an independent predictor of postoperative hypothyroidism and improved discrimination of predicted probabilities based on preoperative TSH.
- Open Access
- 8 July 2025
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 27 (1) , e72097
External Validation of an Upgraded AI Model for Screening Ileocolic Intussusception Using Pediatric Abdominal Radiographs: Multicenter Retrospective Study
Background: Artificial intelligence (AI) is increasingly used in radiology, but its development in pediatric imaging remains limited, particularly for emergent conditions. Ileocolic intussusception is an important cause of acute abdominal pain in infants and toddlers and requires timely diagnosis to prevent complications such as bowel ischemia or perforation. While ultrasonography is the diagnostic standard due to its high sensitivity and specificity, its accessibility may be limited, especially outside tertiary centers. Abdominal radiographs (AXRs), despite their limited sensitivity, are often the first-line imaging modality in clinical practice. In this context, AI could support early screening and triage by analyzing AXRs and identifying patients who require further ultrasonography evaluation. Objective: This study aimed to upgrade and externally validate an AI model for screening ileocolic intussusception using pediatric AXRs with multicenter data and to assess the diagnostic performance of the model in comparison with radiologists of varying experience levels with and without AI assistance. Methods: This retrospective study included pediatric patients (≤5 years) who underwent both AXRs and ultrasonography for suspected intussusception. Based on the preliminary study from hospital A, the AI model was retrained using data from hospital B and validated with external datasets from hospitals C and D. Diagnostic performance of the upgraded AI model was evaluated using sensitivity, specificity, and the area under the receiver operating characteristic curve (AUC). A reader study was conducted with 3 radiologists, including 2 trainees and 1 pediatric radiologist, to evaluate diagnostic performance with and without AI assistance. Results: Based on the previously developed AI model trained on 746 patients from hospital A, an additional 431 patients from hospital B (including 143 intussusception cases) were used for further training to develop an upgraded AI model. External validation was conducted using data from hospital C (n=68; 19 intussusception cases) and hospital D (n=90; 30 intussusception cases). The upgraded AI model achieved a sensitivity of 81.7% (95% CI 68.6%‐90%) and a specificity of 81.7% (95% CI 73.3%‐87.8%), with an AUC of 86.2% (95% CI 79.2%‐92.1%) in the external validation set. Without AI assistance, radiologists showed lower performance (overall AUC 64%; sensitivity 49.7%; specificity 77.1%). With AI assistance, radiologists’ specificity improved to 93% (difference +15.9%; P<.001), and AUC increased to 79.2% (difference +15.2%; P=.05). The least experienced reader showed the largest improvement in specificity (+37.6%; P<.001) and AUC (+14.7%; P=.08). Conclusions: The upgraded AI model improved diagnostic performance for screening ileocolic intussusception on pediatric AXRs. It effectively enhanced the specificity and overall accuracy of radiologists, particularly those with less experience in pediatric radiology. A user-friendly software platform was introduced to support broader clinical validation and underscores the potential of AI as a screening and triage tool in pediatric emergency settings.
- 8 July 2025
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 27 (1) , e72097
Open AccessExternal Validation of an Upgraded AI Model for Screening Ileocolic Intussusception Using Pediatric Abdominal Radiographs: Multicenter Retrospective Study
Background: Artificial intelligence (AI) is increasingly used in radiology, but its development in pediatric imaging remains limited, particularly for emergent conditions. Ileocolic intussusception is an important cause of acute abdominal pain in infants and toddlers and requires timely diagnosis to prevent complications such as bowel ischemia or perforation. While ultrasonography is the diagnostic standard due to its high sensitivity and specificity, its accessibility may be limited, especially outside tertiary centers. Abdominal radiographs (AXRs), despite their limited sensitivity, are often the first-line imaging modality in clinical practice. In this context, AI could support early screening and triage by analyzing AXRs and identifying patients who require further ultrasonography evaluation. Objective: This study aimed to upgrade and externally validate an AI model for screening ileocolic intussusception using pediatric AXRs with multicenter data and to assess the diagnostic performance of the model in comparison with radiologists of varying experience levels with and without AI assistance. Methods: This retrospective study included pediatric patients (≤5 years) who underwent both AXRs and ultrasonography for suspected intussusception. Based on the preliminary study from hospital A, the AI model was retrained using data from hospital B and validated with external datasets from hospitals C and D. Diagnostic performance of the upgraded AI model was evaluated using sensitivity, specificity, and the area under the receiver operating characteristic curve (AUC). A reader study was conducted with 3 radiologists, including 2 trainees and 1 pediatric radiologist, to evaluate diagnostic performance with and without AI assistance. Results: Based on the previously developed AI model trained on 746 patients from hospital A, an additional 431 patients from hospital B (including 143 intussusception cases) were used for further training to develop an upgraded AI model. External validation was conducted using data from hospital C (n=68; 19 intussusception cases) and hospital D (n=90; 30 intussusception cases). The upgraded AI model achieved a sensitivity of 81.7% (95% CI 68.6%‐90%) and a specificity of 81.7% (95% CI 73.3%‐87.8%), with an AUC of 86.2% (95% CI 79.2%‐92.1%) in the external validation set. Without AI assistance, radiologists showed lower performance (overall AUC 64%; sensitivity 49.7%; specificity 77.1%). With AI assistance, radiologists’ specificity improved to 93% (difference +15.9%; P<.001), and AUC increased to 79.2% (difference +15.2%; P=.05). The least experienced reader showed the largest improvement in specificity (+37.6%; P<.001) and AUC (+14.7%; P=.08). Conclusions: The upgraded AI model improved diagnostic performance for screening ileocolic intussusception on pediatric AXRs. It effectively enhanced the specificity and overall accuracy of radiologists, particularly those with less experience in pediatric radiology. A user-friendly software platform was introduced to support broader clinical validation and underscores the potential of AI as a screening and triage tool in pediatric emergency settings.
- Top Cited Papers
- 1 January 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 314 (1) , e240701
Large-Scale Validation of the Feasibility of GPT-4 as a Proofreading Tool for Head CT Reports
OpenAI’s GPT-4 could detect, reason, and revise errors in head CT reports, demonstrating its feasibility as a tool for proofreading radiology reports.
- 1 January 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 314 (1) , e240701
Top Cited PapersLarge-Scale Validation of the Feasibility of GPT-4 as a Proofreading Tool for Head CT Reports
OpenAI’s GPT-4 could detect, reason, and revise errors in head CT reports, demonstrating its feasibility as a tool for proofreading radiology reports.
- 2 June 2023
- Published by Elsevier in Transportation Research Part C: Emerging Technologies
- Vol. 152, 104183
Trajectory-based embedding for random coefficients of a theory-based car-following model
- 2 June 2023
- Published by Elsevier in Transportation Research Part C: Emerging Technologies
- Vol. 152, 104183
Trajectory-based embedding for random coefficients of a theory-based car-following model
- 1 October 2021
- Published by Elsevier in Transportation Research Part C: Emerging Technologies
- Vol. 131, 103347
Variational embedding of a hidden Markov model to generate human activity sequences
- 1 October 2021
- Published by Elsevier in Transportation Research Part C: Emerging Technologies
- Vol. 131, 103347
Variational embedding of a hidden Markov model to generate human activity sequences