Usasi Chowdhury
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Usasi Chowdhury has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Monfardini
Université Grenoble Alpes
3 shared publications - Martino Calvo
Université Grenoble Alpes
3 shared publications - A. Acevedo-Rentería
Universidad Nacional Autónoma de México
2 shared publications - Andrea Mazzolari
INFN Sezione di Ferrara
2 shared publications - Andrea Tartari
INFN Sezione di Pisa
2 shared publications - Angelo Cruciani
Istituto Nazionale di Fisica Nucleare – Sezione di Roma
2 shared publications
Latest Publications
- Open Access
- 6 November 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 114 (9)
Background of the BULLKID detector array operated with a moderate shield on the surface
We present the operation with moderate radiation shield in a surface laboratory of BULky and Low-threshold Kinetic Inductance Detector) (BULLKID), a cryogenic detector for searches of light dark matter or coherent elastic neutrino-nucleus scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The analysis presented focuses on data from 15 elements of the array, with two central units used to evaluate the background and with their surrounding elements used as veto. The low energy spectrum resulting from an exposure of 290 hours to ambient backgrounds, acquired with the use of external and internal radiation shields, is compatible with the simulations at the level of ( 6.8 ± 0.4 stat . ± 0.1 syst . ) × 10 4 counts / keV kg days from 2 keV down to an energy of 600 eV. The region between 225 eV and 600 eV shows a rise in background in disagreement with the simulations, while not sharing some of the key traits of the low energy excess observed in other cryogenic experiments. The high energy spectrum shape is in overall agreement with the simulations and displays the typical particle-induced x-ray emission of the surrounding lead.
- 6 November 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 114 (9)
Open AccessBackground of the BULLKID detector array operated with a moderate shield on the surface
We present the operation with moderate radiation shield in a surface laboratory of BULky and Low-threshold Kinetic Inductance Detector) (BULLKID), a cryogenic detector for searches of light dark matter or coherent elastic neutrino-nucleus scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The analysis presented focuses on data from 15 elements of the array, with two central units used to evaluate the background and with their surrounding elements used as veto. The low energy spectrum resulting from an exposure of 290 hours to ambient backgrounds, acquired with the use of external and internal radiation shields, is compatible with the simulations at the level of ( 6.8 ± 0.4 stat . ± 0.1 syst . ) × 10 4 counts / keV kg days from 2 keV down to an energy of 600 eV. The region between 225 eV and 600 eV shows a rise in background in disagreement with the simulations, while not sharing some of the key traits of the low energy excess observed in other cryogenic experiments. The high energy spectrum shape is in overall agreement with the simulations and displays the typical particle-induced x-ray emission of the surrounding lead.
- 8 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Spectrometers based on Kinetic Inductance Detectors
Spectromètres basés sur des détecteurs à inductance cinétique: Pas de résumé
- 8 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Spectrometers based on Kinetic Inductance Detectors
Spectromètres basés sur des détecteurs à inductance cinétique: Pas de résumé
- Open Access
- 23 March 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (3)
Energy calibration of bulk events in the BULLKID detector
BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates, with mass $$\lesssim 1$$ GeV/c $$^2$$ , and coherent neutrino-nucleus scattering. It is based on an array of dice carved in 5 mm thick silicon crystal, sensed by phonon-mediated Kinetic Inductance Detectors. In previous works, the array was calibrated with bursts of optical photons, which are absorbed in the first hundreds nanometers of the dice and give rise to surface events. In this work, we present the reconstruction of bulk events through the 59.5 keV $$\gamma $$ -ray generated by an $$^{241}$$ Am source, which emulates more closely the interaction of Dark Matter and neutrinos. The peak resolution is $$5\%~(\sigma )$$ and its position is shifted by less than $$10\%$$ with respect to the optical calibration. We observe that the resolution is further improved by a factor 2 combining the signal from neighboring dice. These results confirm the performance of the detector in view of the physics goals of the BULLKID-DM experiment for dark matter search.- 23 March 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (3)
Open AccessEnergy calibration of bulk events in the BULLKID detector
BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates, with mass $$\lesssim 1$$ GeV/c $$^2$$ , and coherent neutrino-nucleus scattering. It is based on an array of dice carved in 5 mm thick silicon crystal, sensed by phonon-mediated Kinetic Inductance Detectors. In previous works, the array was calibrated with bursts of optical photons, which are absorbed in the first hundreds nanometers of the dice and give rise to surface events. In this work, we present the reconstruction of bulk events through the 59.5 keV $$\gamma $$ -ray generated by an $$^{241}$$ Am source, which emulates more closely the interaction of Dark Matter and neutrinos. The peak resolution is $$5\%~(\sigma )$$ and its position is shifted by less than $$10\%$$ with respect to the optical calibration. We observe that the resolution is further improved by a factor 2 combining the signal from neighboring dice. These results confirm the performance of the detector in view of the physics goals of the BULLKID-DM experiment for dark matter search. - 27 January 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (4)
Magnetic field tunable spectral response of kinetic inductance detectors
We tune the onset of optical response in aluminum kinetic inductance detectors from a natural cutoff frequency of 90 GHz to 60 GHz by applying an external magnetic field. The change in the spectral response is due to the decrease in the superconducting gap, from 90 GHz at zero magnetic field to 60 GHz at a magnetic field of around 3 mT. We characterize the variation of the superconducting gap, the detector frequency shift, and the internal quality factor as a function of the applied field. In principle, the magnetic field tunable response could be used to make spectroscopic measurements. In practice, the internal quality factor behaves hysterically with the magnetic field due to the presence of vortices in the thin superconducting film. We conclude by discussing possible solutions to achieve spectroscopy measurements using kinetic inductance detectors and magnetic field.
- 27 January 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (4)
Magnetic field tunable spectral response of kinetic inductance detectors
We tune the onset of optical response in aluminum kinetic inductance detectors from a natural cutoff frequency of 90 GHz to 60 GHz by applying an external magnetic field. The change in the spectral response is due to the decrease in the superconducting gap, from 90 GHz at zero magnetic field to 60 GHz at a magnetic field of around 3 mT. We characterize the variation of the superconducting gap, the detector frequency shift, and the internal quality factor as a function of the applied field. In principle, the magnetic field tunable response could be used to make spectroscopic measurements. In practice, the internal quality factor behaves hysterically with the magnetic field due to the presence of vortices in the thin superconducting film. We conclude by discussing possible solutions to achieve spectroscopy measurements using kinetic inductance detectors and magnetic field.