Wan Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wan Kim has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Hwa-Pyeong Park
Korea Institute of Energy Technology (KENTECH), Naju-si, South Korea
11 shared publications Byungki Kim
Department of Power Systems, Korea Institute of Energy Research, Jeju, South Korea
3 shared publicationsChun-Sung Kim
Green Energy Institute, Mokpo-si, South Korea
2 shared publicationsMina Kim
Hanbat National University, Daejeon, South Korea
2 shared publications- Mina Kim
Hanbat National University, Daejeon, South Korea
2 shared publications Minseo Jeon
2 shared publications
Latest Publications
- Open Access
- 20 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 44293-44302
Enhanced DC Series Arc-Fault Detection in LVDC Systems With Capacitor-Assisted Impedance Shaping
A DC grid can achieve high power conversion efficiency by reducing conversion stages between DC energy resources and loads. However, as system complexity increases, DC distribution systems face series arc faults due to damaged power cables and loose connectors, which can induce a fire hazard. Unlike AC grids, DC grids lack natural current and voltage zero crossings, which complicates arc-fault detection. This paper investigates series arc fault detection in LVDC systems with auxiliary DC-link/feeder capacitance for impedance shaping. The proposed capacitor-assisted impedance shaping increases the magnitude of arc-induced current variation and strengthens the frequency-spectrum change of the line current used by the FFT-based detector, thereby improving DC series arc-fault detectability. The operational principle is analyzed to derive capacitance-based impedance-shaping design guidelines for such LVDC systems. Also, a hybrid detector combines time-domain and frequency-domain analyses to detect DC series arc faults, which utilizes the arc characteristics of DC and AC components. Experimental validation of the proposed structure and detection algorithm is performed on a 30-kW laboratory LVDC testbed.
- 20 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 44293-44302
Open AccessEnhanced DC Series Arc-Fault Detection in LVDC Systems With Capacitor-Assisted Impedance Shaping
A DC grid can achieve high power conversion efficiency by reducing conversion stages between DC energy resources and loads. However, as system complexity increases, DC distribution systems face series arc faults due to damaged power cables and loose connectors, which can induce a fire hazard. Unlike AC grids, DC grids lack natural current and voltage zero crossings, which complicates arc-fault detection. This paper investigates series arc fault detection in LVDC systems with auxiliary DC-link/feeder capacitance for impedance shaping. The proposed capacitor-assisted impedance shaping increases the magnitude of arc-induced current variation and strengthens the frequency-spectrum change of the line current used by the FFT-based detector, thereby improving DC series arc-fault detectability. The operational principle is analyzed to derive capacitance-based impedance-shaping design guidelines for such LVDC systems. Also, a hybrid detector combines time-domain and frequency-domain analyses to detect DC series arc faults, which utilizes the arc characteristics of DC and AC components. Experimental validation of the proposed structure and detection algorithm is performed on a 30-kW laboratory LVDC testbed.
- 6 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 4019-4028
Coordination of Time-Frequency Domain Analysis and Current Modulation Algorithm for Series Arc Fault Detection and Extinguishing
Power generation using a photovoltaic (PV) system is increasing to achieve the carbon neutrality. Module-level power electronics (MLPEs) can optimize power generation for each PV panel. However, it increases the possibility of dc series arc fault condition between the PV panel and MLPEs. The broken and loose connector and damaged cable can induce a dc series arc fault condition. Previously, frequency domain analysis using PV current, such as Fourier transform and wavelet transform, was widely employed for arc fault detection. However, it has limited performance in accuracy according to operating conditions. This article proposes the dc series arc fault detection and extinguishing algorithm with coordination of time and frequency domain analysis, and dc current modulation. The arc resistance characteristics is analyzed to detect the fault condition according to the power rating. The MLPE modulates the dc current to optimize the arc fault detection. In addition, it can extinguish the arc fault condition using the current modulation. Therefore, the dc series arc fault condition is double detected through signal processing and current modulation. Experimental results can verify the fault detection and extinguishing capability.
- 6 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 4019-4028
Coordination of Time-Frequency Domain Analysis and Current Modulation Algorithm for Series Arc Fault Detection and Extinguishing
Power generation using a photovoltaic (PV) system is increasing to achieve the carbon neutrality. Module-level power electronics (MLPEs) can optimize power generation for each PV panel. However, it increases the possibility of dc series arc fault condition between the PV panel and MLPEs. The broken and loose connector and damaged cable can induce a dc series arc fault condition. Previously, frequency domain analysis using PV current, such as Fourier transform and wavelet transform, was widely employed for arc fault detection. However, it has limited performance in accuracy according to operating conditions. This article proposes the dc series arc fault detection and extinguishing algorithm with coordination of time and frequency domain analysis, and dc current modulation. The arc resistance characteristics is analyzed to detect the fault condition according to the power rating. The MLPE modulates the dc current to optimize the arc fault detection. In addition, it can extinguish the arc fault condition using the current modulation. Therefore, the dc series arc fault condition is double detected through signal processing and current modulation. Experimental results can verify the fault detection and extinguishing capability.
- 31 October 2025
- Published by The Korean Institute of Power Electronics in THE TRANSACTIONS OF KOREAN INSTITUTE OF POWER ELECTRONICS
- Vol. 30 (5) , 426-434
Real-Time Detection of DC Series Arc Faults Using On-Device AI
With the rapid expansion of renewable energy, especially photovoltaic (PV) systems, the occurrence rate of DC series arc faults has considerably increased, necessitating prompt and accurate detection. Although previous studies have proposed AI-based detection methods for DC arc faults, most of these approaches require external hardware to perform learning and inference, resulting in additional costs and detection delay. To overcome these limitations, this study proposes a real-time detection method for DC series arc faults that uses digital signal processor (DSP)-based on-device AI. The proposed system directly processes current signals from sensors, performs real-time feature extraction, and classifies fault conditions by using a random forest model embedded within DSP. It operates independently without reliance on external computing resources. The proposed algorithm is validated through simulation and experiments, and it achieves a classification accuracy of 99.83% and a detection speed that is compliant with the UL 1699B standard. Results demonstrate the practical applicability of the proposed method in enhancing the stability and reliability of PV systems.
- 31 October 2025
- Published by The Korean Institute of Power Electronics in THE TRANSACTIONS OF KOREAN INSTITUTE OF POWER ELECTRONICS
- Vol. 30 (5) , 426-434
Real-Time Detection of DC Series Arc Faults Using On-Device AI
With the rapid expansion of renewable energy, especially photovoltaic (PV) systems, the occurrence rate of DC series arc faults has considerably increased, necessitating prompt and accurate detection. Although previous studies have proposed AI-based detection methods for DC arc faults, most of these approaches require external hardware to perform learning and inference, resulting in additional costs and detection delay. To overcome these limitations, this study proposes a real-time detection method for DC series arc faults that uses digital signal processor (DSP)-based on-device AI. The proposed system directly processes current signals from sensors, performs real-time feature extraction, and classifies fault conditions by using a random forest model embedded within DSP. It operates independently without reliance on external computing resources. The proposed algorithm is validated through simulation and experiments, and it achieves a classification accuracy of 99.83% and a detection speed that is compliant with the UL 1699B standard. Results demonstrate the practical applicability of the proposed method in enhancing the stability and reliability of PV systems.
- Open Access
- 20 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 109057-109068
Design Methodology of Power-Level Modulation for PV Power Loss Minimization and DC Series Arc Fault Detection and Extinguishing
With the recent surge in the use of photovoltaic (PV) power systems, the incidence of DC series arc faults has significantly increased, which cause voltage drops within these systems. Previous studies have proposed arc fault detection algorithms based on these input voltage drops. However, voltage drops can also occur under normal conditions, such as irradiance variations. Operating the conventional arc fault detection algorithm under normal conditions, such as irradiance variations, results in a reduction in PV power generation. To overcome these limitations, this paper proposes a new algorithm that not only detects and extinguishes DC series arc faults but also minimizes the reduction in PV power generation under normal conditions, such as irradiance variations. The proposed method uses Q1 and Q2 of a non-inverting buck-boost converter to separate the detection and extinguishing processes of arc faults and detects arc faults through sinusoidal current control. The algorithm was validated through simulation models and experiments, and it achieved a power generation efficiency of 75.84% under irradiance variation, demonstrating effective operation without unnecessary energy loss and confirming its ability to enhance the stability and reliability of PV systems. Furthermore, it holds promise for application in more complex power systems in the future and is expected to contribute to a wide range of power system applications.
- 20 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 109057-109068
Open AccessDesign Methodology of Power-Level Modulation for PV Power Loss Minimization and DC Series Arc Fault Detection and Extinguishing
With the recent surge in the use of photovoltaic (PV) power systems, the incidence of DC series arc faults has significantly increased, which cause voltage drops within these systems. Previous studies have proposed arc fault detection algorithms based on these input voltage drops. However, voltage drops can also occur under normal conditions, such as irradiance variations. Operating the conventional arc fault detection algorithm under normal conditions, such as irradiance variations, results in a reduction in PV power generation. To overcome these limitations, this paper proposes a new algorithm that not only detects and extinguishes DC series arc faults but also minimizes the reduction in PV power generation under normal conditions, such as irradiance variations. The proposed method uses Q1 and Q2 of a non-inverting buck-boost converter to separate the detection and extinguishing processes of arc faults and detects arc faults through sinusoidal current control. The algorithm was validated through simulation models and experiments, and it achieved a power generation efficiency of 75.84% under irradiance variation, demonstrating effective operation without unnecessary energy loss and confirming its ability to enhance the stability and reliability of PV systems. Furthermore, it holds promise for application in more complex power systems in the future and is expected to contribute to a wide range of power system applications.
- 14 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (11) , 16061-16067
Coordination of Machine Learning and Current Modulation for DC Series Arc Fault Detection and Extinguishing for Module-Level PV Systems
Module-level power electronics can achieve the maximum power generation for each photovoltaic (PV) panel with overcoming the partial shading. However, it increases the possibility of dc series arc fault condition between the PV panel and converter. The current modulation can detect and extinguish the dc series arc fault condition using the characteristics of arc resistance. However, this method degrades the power generation according to inaccurate fault detection. This article proposes the dc series arc fault detection and extinguishing with coordination of current modulation and machine learning method, which can improve the accuracy of fault detection through double screening. The proper machine learning algorithm can minimize the undesired trigger of current modulation, which improves the PV power generation at normal condition. The proposed method is possible to distinguish between arc fault and normal conditions regardless of impedance and external changes. The operational principle is analyzed to coordinate the current modulation and machine learning. The experimental results using 800-W prototype dc–dc converter can verify the arc fault detection and extinguishing.
- 14 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (11) , 16061-16067
Coordination of Machine Learning and Current Modulation for DC Series Arc Fault Detection and Extinguishing for Module-Level PV Systems
Module-level power electronics can achieve the maximum power generation for each photovoltaic (PV) panel with overcoming the partial shading. However, it increases the possibility of dc series arc fault condition between the PV panel and converter. The current modulation can detect and extinguish the dc series arc fault condition using the characteristics of arc resistance. However, this method degrades the power generation according to inaccurate fault detection. This article proposes the dc series arc fault detection and extinguishing with coordination of current modulation and machine learning method, which can improve the accuracy of fault detection through double screening. The proper machine learning algorithm can minimize the undesired trigger of current modulation, which improves the PV power generation at normal condition. The proposed method is possible to distinguish between arc fault and normal conditions regardless of impedance and external changes. The operational principle is analyzed to coordinate the current modulation and machine learning. The experimental results using 800-W prototype dc–dc converter can verify the arc fault detection and extinguishing.
- 11 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (6) , 7489-7498
DC Series Arc Fault Detection Capability With Non-Inverting Buck–Boost Converter for Module-Level Power Electronics Applications
Module-level power electronics can optimize power generation for each photovoltaic (PV) panel. However, it increases the possibility of DC series arc fault between the PV panel and DC-DC converter. The damaged and loose connector can induce arc faults. Previously, frequency domain analysis using PV current, such as Fourier transform and wavelet transform, was widely employed for series arc fault detection. However, fault detection with signal processing is not consistent with system configurations. In this paper, the characteristics of arc resistance are investigated to detect and extinguish arc faults using the power modulation and signal processing. A non-inverting buck-boost (NIBB) converter is analyzed according to control freedom to implement power modulation. A duty modulation strategy for the non-inverting buck-boost converter is designed for series arc fault detection and extinguishing with considerations of arc and PV characteristics. A hybrid algorithm using time domain analysis is proposed, which can classify normal and arc fault conditions. It can maximize power generation under normal conditions. Experimental results using an 800-W prototype verify the performance of proposed modulation algorithm.
- 11 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (6) , 7489-7498
DC Series Arc Fault Detection Capability With Non-Inverting Buck–Boost Converter for Module-Level Power Electronics Applications
Module-level power electronics can optimize power generation for each photovoltaic (PV) panel. However, it increases the possibility of DC series arc fault between the PV panel and DC-DC converter. The damaged and loose connector can induce arc faults. Previously, frequency domain analysis using PV current, such as Fourier transform and wavelet transform, was widely employed for series arc fault detection. However, fault detection with signal processing is not consistent with system configurations. In this paper, the characteristics of arc resistance are investigated to detect and extinguish arc faults using the power modulation and signal processing. A non-inverting buck-boost (NIBB) converter is analyzed according to control freedom to implement power modulation. A duty modulation strategy for the non-inverting buck-boost converter is designed for series arc fault detection and extinguishing with considerations of arc and PV characteristics. A hybrid algorithm using time domain analysis is proposed, which can classify normal and arc fault conditions. It can maximize power generation under normal conditions. Experimental results using an 800-W prototype verify the performance of proposed modulation algorithm.
- Open Access
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 49504-49513
DC Series Arc Fault Detection and Extinguishing With Modulation Algorithm of Non-Inverting Buck-Boost Converter for PV Applications
Power generation using a photovoltaic (PV) system is increasing to achieve the carbon neutrality. Module-level power electronics (MLPEs) can optimize power generation for each PV panel. However, it increases the possibility of DC series arc fault condition between the PV panel and MLPEs. The broken and loose connector and damaged cable can induce a DC series arc fault condition. Previously, frequency domain analysis using PV current, such as Fourier transform and wavelet transform, was widely employed for DC series arc fault detection. It requires the auxiliary device to detect the arc failure, which degrades the cost-effectiveness of PV systems. In addition, they cannot achieve the fault detection and extinguishing in the same time. This paper proposes a modulation algorithm of non-inverting buck-boost converter (NIBBC) to achieve the DC series arc fault detection and extinguishing. The proposed method uses the characteristics of PV, NIBBC, and arc fault to classify the normal and arc fault conditions. The operational principle is analyzed to design the modulation method according to operating modes. The 800-W prototype NIBBC is used to verify the performance of series arc fault detection and extinguishing.
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 49504-49513
Open AccessDC Series Arc Fault Detection and Extinguishing With Modulation Algorithm of Non-Inverting Buck-Boost Converter for PV Applications
Power generation using a photovoltaic (PV) system is increasing to achieve the carbon neutrality. Module-level power electronics (MLPEs) can optimize power generation for each PV panel. However, it increases the possibility of DC series arc fault condition between the PV panel and MLPEs. The broken and loose connector and damaged cable can induce a DC series arc fault condition. Previously, frequency domain analysis using PV current, such as Fourier transform and wavelet transform, was widely employed for DC series arc fault detection. It requires the auxiliary device to detect the arc failure, which degrades the cost-effectiveness of PV systems. In addition, they cannot achieve the fault detection and extinguishing in the same time. This paper proposes a modulation algorithm of non-inverting buck-boost converter (NIBBC) to achieve the DC series arc fault detection and extinguishing. The proposed method uses the characteristics of PV, NIBBC, and arc fault to classify the normal and arc fault conditions. The operational principle is analyzed to design the modulation method according to operating modes. The 800-W prototype NIBBC is used to verify the performance of series arc fault detection and extinguishing.
- Open Access
- 25 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 39343-39352
DC Series Arc Fault Detection Capability Using Auxiliary Filter for Module-Level PV Systems
A module-level power electronics for photovoltaic (PV) systems can achieve the maximum power generation for each PV panel, which can overcome the partial shading of PV systems. However, it increases the possibility of series arc fault condition between the PV panel and module-level power electronics. The damaged and loose connector can induce the DC series arc fault condition. This paper investigates DC series arc fault detection capability based on the non-inverting buck-boost converter using the resonant filter for the PV applications. From the arc fault characteristics, the designed impedance model can clarify the DC series arc fault condition. The operational principle and design methodology of proposed buck-boost converter are analyzed with considerations of power conversion and series arc fault detection capability. The experimental results using the 800-W prototype converter can verify the series arc fault detection capability with proposed topology using the resonant filter.
- 25 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 39343-39352
Open AccessDC Series Arc Fault Detection Capability Using Auxiliary Filter for Module-Level PV Systems
A module-level power electronics for photovoltaic (PV) systems can achieve the maximum power generation for each PV panel, which can overcome the partial shading of PV systems. However, it increases the possibility of series arc fault condition between the PV panel and module-level power electronics. The damaged and loose connector can induce the DC series arc fault condition. This paper investigates DC series arc fault detection capability based on the non-inverting buck-boost converter using the resonant filter for the PV applications. From the arc fault characteristics, the designed impedance model can clarify the DC series arc fault condition. The operational principle and design methodology of proposed buck-boost converter are analyzed with considerations of power conversion and series arc fault detection capability. The experimental results using the 800-W prototype converter can verify the series arc fault detection capability with proposed topology using the resonant filter.
- 5 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. PP (08858969) , 1-12
DC Series Arc Fault Detection Capability With Frequency Spectrum Analysis Using LCL-Type Boost Converter for PV Applications
Module level power electronics can achieve the maximum power generation for each photovoltaic (PV) panel. However, it increases the possibility of an arc fault between the PV panel and the DC/DC converter. The damaged and loose connector can induce the DC series arc fault condition. Previously, the frequency-domain analysis using PV current, such as Fourier transform and wavelet transform, was widely employed for series arc fault detection. However, the arc fault detection performance is not consistent according to the system configuration. This paper investigates the DC series arc fault capability using the frequency spectrum analysis based on the impedance of the power converter. From the characteristics of the arc fault condition, the boost converter comprising the LCL-type filter can clarify the arc fault condition in the frequency-domain analysis. The operational principle and design methods are analyzed while considering series arc fault detection and power conversion. The experimental results using an 800-W prototype converter can verify the arc fault detection using the frequency spectrum analysis.
- 5 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. PP (08858969) , 1-12
DC Series Arc Fault Detection Capability With Frequency Spectrum Analysis Using LCL-Type Boost Converter for PV Applications
Module level power electronics can achieve the maximum power generation for each photovoltaic (PV) panel. However, it increases the possibility of an arc fault between the PV panel and the DC/DC converter. The damaged and loose connector can induce the DC series arc fault condition. Previously, the frequency-domain analysis using PV current, such as Fourier transform and wavelet transform, was widely employed for series arc fault detection. However, the arc fault detection performance is not consistent according to the system configuration. This paper investigates the DC series arc fault capability using the frequency spectrum analysis based on the impedance of the power converter. From the characteristics of the arc fault condition, the boost converter comprising the LCL-type filter can clarify the arc fault condition in the frequency-domain analysis. The operational principle and design methods are analyzed while considering series arc fault detection and power conversion. The experimental results using an 800-W prototype converter can verify the arc fault detection using the frequency spectrum analysis.