Michael Hawks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael Hawks has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Anthony L. Franz
Center for Technical Intelligence Studies and Research, Air Force Institute of Technology, 2950 Hobson Way, Fairborn, OH 45433, USA
1 shared publication Francis D. Hallada
Air Force Institute of Technology, Department of Engineering Physics, Wright Patterson Air Force Base, United States
1 shared publicationMichael Dexter
Air Force Institute of Technology, Center for Technical Intelligence Studies and Research, Wright-Pa
1 shared publicationR Anthony Vincent
Air Force Institute of Technology
1 shared publication
Latest Publications
- Open Access
- 5 February 2025
- Published by Qeios Ltd
Review of: "Towards End-to-End Neuromorphic Voxel-based 3D Object Reconstruction Without Physical Priors"
I liked your point about the speed difference enabled by the neuromorphic sensor – I look forward to seeing more quantitative comparisons of that issue. Presenting the threshold selection as a “Principle” or a major contribution seems spuri...
- 5 February 2025
- Published by Qeios Ltd
Open AccessReview of: "Towards End-to-End Neuromorphic Voxel-based 3D Object Reconstruction Without Physical Priors"
I liked your point about the speed difference enabled by the neuromorphic sensor – I look forward to seeing more quantitative comparisons of that issue. Presenting the threshold selection as a “Principle” or a major contribution seems spuri...
- Open Access
- 1 May 2022
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 61 (05) , 053101-10
Event-based imaging polarimeter
The design and initial experimental results from an event-based, rotating-polarizer, imaging polarimeter are presented. The speed of division-of-time imaging systems is traditionally constrained by the frame rate of the focal plane sensor and the need to sample several polarization angles during rotation. The asynchronous event reporting of event-based cameras (EBCs) frees these constraints but introduces challenges. The Stokes vectors used to describe polarization are based on irradiance, but EBCs are inherently change-detection systems that struggle to estimate irradiance. Two methods of estimating the polarization state without first recovering irradiance images are presented and compared. The DAVIS 346 sensor enables simultaneous recording of events with conventional frame-based images, enabling direct comparison of event-based polarization estimates to traditional techniques.
- 1 May 2022
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 61 (05) , 053101-10
Open AccessEvent-based imaging polarimeter
The design and initial experimental results from an event-based, rotating-polarizer, imaging polarimeter are presented. The speed of division-of-time imaging systems is traditionally constrained by the frame rate of the focal plane sensor and the need to sample several polarization angles during rotation. The asynchronous event reporting of event-based cameras (EBCs) frees these constraints but introduces challenges. The Stokes vectors used to describe polarization are based on irradiance, but EBCs are inherently change-detection systems that struggle to estimate irradiance. Two methods of estimating the polarization state without first recovering irradiance images are presented and compared. The DAVIS 346 sensor enables simultaneous recording of events with conventional frame-based images, enabling direct comparison of event-based polarization estimates to traditional techniques.
- 21 July 2017
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 56 (8) , 081811
Fresnel zone plate light field spectral imaging
This paper discusses computational modeling and experimental demonstration of a Fresnel zone light field spectral imaging system. This type of system couples an axial dispersion binary diffractive optic with a light field detector design providing a snapshot spectral imaging capability. The computational model was validated experimentally and provides excellent predictions of potential system capabilities. Additionally, the experimentally demonstrated prototype was able to digitally refocus monochromatic images by wavelength across greater than a 100 nm bandwidth. Through simulation, the demonstrated system was approximated to have a full range from to 800 nm at close to a 15-nm spectral sampling interval. We also demonstrated experimentally the capability of resolving between and processing two different spectral signatures in a single snapshot. The type of system demonstrated here offers substantial new capability as an optically simple, snapshot spectral imager. The experimental proof of concept and computational model set the stage for further development of these types of systems.- 21 July 2017
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 56 (8) , 081811
Fresnel zone plate light field spectral imaging
This paper discusses computational modeling and experimental demonstration of a Fresnel zone light field spectral imaging system. This type of system couples an axial dispersion binary diffractive optic with a light field detector design providing a snapshot spectral imaging capability. The computational model was validated experimentally and provides excellent predictions of potential system capabilities. Additionally, the experimentally demonstrated prototype was able to digitally refocus monochromatic images by wavelength across greater than a 100 nm bandwidth. Through simulation, the demonstrated system was approximated to have a full range from to 800 nm at close to a 15-nm spectral sampling interval. We also demonstrated experimentally the capability of resolving between and processing two different spectral signatures in a single snapshot. The type of system demonstrated here offers substantial new capability as an optically simple, snapshot spectral imager. The experimental proof of concept and computational model set the stage for further development of these types of systems.- 13 May 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8052, 80520D-80520D-16
Passive ranging of dynamic rocket plumes using infrared and visible oxygen attenuation
Atmospheric oxygen absorption bands in observed spectra of boost phase missiles can be used to accurately estimate range from sensor to target. One method is to compare observed values of band averaged absorption to radiative transfer models. This is most effective using bands where there is a single absorbing species. This work compares spectral attenuation of two oxygen absorption bands in the near-infrared (NIR) and visible (Vis) spectrum, centered at 762 nm and 690 nm, to passively determine range. Spectra were observed from a static test of a full-scale solid rocket motor at a 900m range. The NIR O2 band provided range estimates accurate to within 3%, while the Vis O2 band had a range error of 15%. A Falcon 9 rocket launch at an initial range of 13km was also tracked and observed for 90 seconds after ignition. The NIR O2 band provided in-flight range estimates accurate to within 2% error for the first 30 seconds of tracked observation. The Vis O2 band also provided accurate range estimates with an error of approximately 4%. Rocket plumes are expected to be significantly brighter at longer wavelengths, but absorption in the NIR band is nearly ten times stronger than the Vis band, causing saturation at shorter path lengths. An atmospheric band is considered saturated when all the in-band frequencies emitted from the rocket plume are absorbed before reaching the sensor.
- 13 May 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8052, 80520D-80520D-16
Passive ranging of dynamic rocket plumes using infrared and visible oxygen attenuation
Atmospheric oxygen absorption bands in observed spectra of boost phase missiles can be used to accurately estimate range from sensor to target. One method is to compare observed values of band averaged absorption to radiative transfer models. This is most effective using bands where there is a single absorbing species. This work compares spectral attenuation of two oxygen absorption bands in the near-infrared (NIR) and visible (Vis) spectrum, centered at 762 nm and 690 nm, to passively determine range. Spectra were observed from a static test of a full-scale solid rocket motor at a 900m range. The NIR O2 band provided range estimates accurate to within 3%, while the Vis O2 band had a range error of 15%. A Falcon 9 rocket launch at an initial range of 13km was also tracked and observed for 90 seconds after ignition. The NIR O2 band provided in-flight range estimates accurate to within 2% error for the first 30 seconds of tracked observation. The Vis O2 band also provided accurate range estimates with an error of approximately 4%. Rocket plumes are expected to be significantly brighter at longer wavelengths, but absorption in the NIR band is nearly ten times stronger than the Vis band, causing saturation at shorter path lengths. An atmospheric band is considered saturated when all the in-band frequencies emitted from the rocket plume are absorbed before reaching the sensor.