TXTao Xie

Tao Xie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tao Xie has a total of 23 co-authors. Here are the top co-authors by number of shared publications:

  • Qingyu Wang

    State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China

    5 shared publications
  • Peng Liu

    State Key Laboratory of Electrical Insulation and Power Equipment in Xi'an Jiaotong University Xi'an China

    4 shared publications
  • Zongren Peng

    State Key Laboratory of Electrical Insulation and Power Equipment in Xi'an Jiaotong University Xi'an China

    4 shared publications
  • Huidong Tian

    State Grid Economic and Technological Institute Co. Beijing China

    2 shared publications
  • Juzhen Wu

    State Grid Economic and Technological Institute Co. Beijing China

    2 shared publications
  • Kanghang He

    State Grid Economic and Technological Institute Co. Beijing China

    2 shared publications

Latest Publications

  • Open Access

    Corrosion Failure Analysis of Contactor Type Electrical Connection Components Used in Converter Valve Side Bushings

    by Qingyu Wang, Tao Xie, Shoufeng Jin, Huidong Tian, Xiaoyu Zhou, Shifeng Shi, Kanghang He, Juzhen Wu, Peng Liu, Zongren Peng

    As a commonly used bushing current‐carrying structure in recent years, contactor‐type electrical connection parts operate in a complex environment of electric, thermal and chemical corrosion for extended periods. With the increase of ultra‐high voltage (UHV) transmission capacity, its operating environment faces more stringent challenges, and the stability of their operation is directly linked to the reliability of the UHV transformer equipment. This paper aims to investigate the mechanism behind contact failure by developing a contactor deterioration test platform in oil to study the deterioration and corrosion process of strap contactor in oil under 120°C environment. The study found that the sulphur element content on the exposed copper surface of the strap contactor was elevated from 0% to 2.05% in 28 days, and there was an obvious latency period for the sulphide corrosive reaction with the surface of the strap contactor. The electrical contact resistance of the strap contactor after the corrosion reaction was elevated from 110 to 251 μΩ, which became overheating failure and contact failure of electrical connection components of bushings.


  • Molecular Dynamics Simulation of Normal Contact and Friction Behaviors of Strap Contacts Used in High Voltage Bushings

    by Xiaoyu Zhou, Rui Wang, Songbo Tian, Tao Xie, Shoufeng Jin, Qingyu Wang, Peng Liu, Zongren Peng

  • Study of microstructural evolution during operation of electrically connected components and analysis of failure mechanism

    by Tao Xie, Xiaoyu Zhou, Shoufeng Jin, Kanghang He, Juzhen Wu, Qingyu Wang, Peng Liu, Zongren Peng

    As a key current-carrying structure of high-voltage bushings, the reliability of electrical connection components is crucial to the safe and stable operation of power equipment. To obtain the microstructural evolution of electrical connection components with different deterioration states, CUD strap contactors were deteriorated in different ways, and electron backscatter diffraction technique was used to test the microstructure of strap contactors with different deterioration states. The results showed that compared to the unused contactors, the contact resistance of the contactors under the combined effect of friction and high temperature increased 203.12 times and was in a failed state. During the process from unused state to wear deterioration, high temperature deterioration, and then to eventual failure of the contactors, the average grain size gradually grows from 8.15 μm to 25 μm, the dislocation density gradually decreases from 2.38 × 1014 m−2 to 1.04 × 1014 m−2, and there are a significant proportion of the recrystallized organization. These changes are detrimental to the mechanical properties of the contactors. In addition, the distribution of grain boundaries in the contact area proves the occurrence of over-temperature phenomenon in this area, which will accelerate the deterioration of the contactors and eventually lead to the failure of the component. The relevant conclusions can provide a theoretical basis for the design of electrical connection structure of strap contacts as well as the study of deterioration mechanism.


  • Insulation Degradation of Epoxy Resin Impregnated Paper Bushing Under Discharge Arc Ablation

    by Shifeng Shi, Huidong Tian, Gengsheng Xie, Qingyu Wang, Tao Xie, Xi Pang, Guangzhong Yang, Peng Liu, Zongren Peng

    Converter transformer valve side bushing is an irreplaceable key equipment in the UHVDC transmission project. In the process of operation, the surface of the epoxy resin impregnated paper (ERIP) core will produce partial discharge due to insulation defects, and the formed discharge arc will destroy the insulation layer, which seriously threatens the safe and stable operation of the valve side bushing. In this paper, an arc ablation experimental platform was built to study the thermal response characteristics of ERIP in SF 6 arc ablation. The surface microscopic morphology and dielectric properties of the samples before and after ablation were compared and analyzed, and the intrinsic mechanism of surface insulation failure was further revealed by a mathematical model. The results show that the huge heat generated by the arc discharge causes the decomposition of the epoxy resin, leading to the gradual increase of the internal porosity and permeability of the material, and the carbon layer structure will be formed on the surface after complete pyrolysis. With the increase of the arc action time, the ERIP is gradually transformed into carbide and pore products, the material surface resistance decreases, the roughness increases, and a local failure region is formed, which reduces the surface electrical properties of the material and ultimately leads to the failure of surface insulation.


  • Open Access

    Research on the Characteristic of the Electrical Contact Resistance of Strap Contacts Used in High Voltage Bushings

    by Jianwei Cheng, Linjie Zhao, Xiaoyu Zhou, Ting Ren, Shoufeng Jin, Tao Xie, Peng Liu, Zongren Peng, Qingyu Wang

    As an important electrical connection component in electrical equipment, the strap contact is directly related to the long-term operation stability of equipment. The electrical contact resistance (ECR) of the electrical connection structure is an important indicator for evaluating the reliability of the electrical contact system. In this research, the theoretical calculation of ECR of the strap contacts used by the G-W theoretical model and the fractal theoretical model is improved and compared. After comparison with the experimental measurement values, the rationality and accuracy of the two theoretical models are discussed. The results show that when the load is small (1–3 N), the maximum error of G-W model is 41%, while the fractal model method has a maximum error of 9%. When the load is large (4–10 N), the results of the two are almost the same, and the errors are both within 14%. In summary, the error range of the fractal model is smaller and the change trend is closer to the experimental value, which is suitable for a relatively better ECR analytical calculation theory. The research results can provide a theoretical basis for research on the electrical contact performance of the electrical contact structure of electrical equipment.