Tao Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tao Xie has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Qingyu Wang
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
5 shared publications Peng Liu
State Key Laboratory of Electrical Insulation and Power Equipment in Xi'an Jiaotong University Xi'an China
4 shared publicationsZongren Peng
State Key Laboratory of Electrical Insulation and Power Equipment in Xi'an Jiaotong University Xi'an China
4 shared publicationsHuidong Tian
State Grid Economic and Technological Institute Co. Beijing China
2 shared publicationsJuzhen Wu
State Grid Economic and Technological Institute Co. Beijing China
2 shared publicationsKanghang He
State Grid Economic and Technological Institute Co. Beijing China
2 shared publications
Latest Publications
- Open Access
- 30 March 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 11 (3) , 705-714
Corrosion Failure Analysis of Contactor Type Electrical Connection Components Used in Converter Valve Side Bushings
As a commonly used bushing current‐carrying structure in recent years, contactor‐type electrical connection parts operate in a complex environment of electric, thermal and chemical corrosion for extended periods. With the increase of ultra‐high voltage (UHV) transmission capacity, its operating environment faces more stringent challenges, and the stability of their operation is directly linked to the reliability of the UHV transformer equipment. This paper aims to investigate the mechanism behind contact failure by developing a contactor deterioration test platform in oil to study the deterioration and corrosion process of strap contactor in oil under 120°C environment. The study found that the sulphur element content on the exposed copper surface of the strap contactor was elevated from 0% to 2.05% in 28 days, and there was an obvious latency period for the sulphide corrosive reaction with the surface of the strap contactor. The electrical contact resistance of the strap contactor after the corrosion reaction was elevated from 110 to 251 μΩ, which became overheating failure and contact failure of electrical connection components of bushings.
- 30 March 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 11 (3) , 705-714
Open AccessCorrosion Failure Analysis of Contactor Type Electrical Connection Components Used in Converter Valve Side Bushings
As a commonly used bushing current‐carrying structure in recent years, contactor‐type electrical connection parts operate in a complex environment of electric, thermal and chemical corrosion for extended periods. With the increase of ultra‐high voltage (UHV) transmission capacity, its operating environment faces more stringent challenges, and the stability of their operation is directly linked to the reliability of the UHV transformer equipment. This paper aims to investigate the mechanism behind contact failure by developing a contactor deterioration test platform in oil to study the deterioration and corrosion process of strap contactor in oil under 120°C environment. The study found that the sulphur element content on the exposed copper surface of the strap contactor was elevated from 0% to 2.05% in 28 days, and there was an obvious latency period for the sulphide corrosive reaction with the surface of the strap contactor. The electrical contact resistance of the strap contactor after the corrosion reaction was elevated from 110 to 251 μΩ, which became overheating failure and contact failure of electrical connection components of bushings.
- 10 December 2024
- Published by Springer Nature
- p. 510-517
Molecular Dynamics Simulation of Normal Contact and Friction Behaviors of Strap Contacts Used in High Voltage Bushings
- 10 December 2024
- Published by Springer Nature
- p. 510-517
Molecular Dynamics Simulation of Normal Contact and Friction Behaviors of Strap Contacts Used in High Voltage Bushings
- 14 November 2024
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 58 (5) , 055502
Study of microstructural evolution during operation of electrically connected components and analysis of failure mechanism
As a key current-carrying structure of high-voltage bushings, the reliability of electrical connection components is crucial to the safe and stable operation of power equipment. To obtain the microstructural evolution of electrical connection components with different deterioration states, CUD strap contactors were deteriorated in different ways, and electron backscatter diffraction technique was used to test the microstructure of strap contactors with different deterioration states. The results showed that compared to the unused contactors, the contact resistance of the contactors under the combined effect of friction and high temperature increased 203.12 times and was in a failed state. During the process from unused state to wear deterioration, high temperature deterioration, and then to eventual failure of the contactors, the average grain size gradually grows from 8.15 μm to 25 μm, the dislocation density gradually decreases from 2.38 × 1014 m−2 to 1.04 × 1014 m−2, and there are a significant proportion of the recrystallized organization. These changes are detrimental to the mechanical properties of the contactors. In addition, the distribution of grain boundaries in the contact area proves the occurrence of over-temperature phenomenon in this area, which will accelerate the deterioration of the contactors and eventually lead to the failure of the component. The relevant conclusions can provide a theoretical basis for the design of electrical connection structure of strap contacts as well as the study of deterioration mechanism.
- 14 November 2024
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 58 (5) , 055502
Study of microstructural evolution during operation of electrically connected components and analysis of failure mechanism
As a key current-carrying structure of high-voltage bushings, the reliability of electrical connection components is crucial to the safe and stable operation of power equipment. To obtain the microstructural evolution of electrical connection components with different deterioration states, CUD strap contactors were deteriorated in different ways, and electron backscatter diffraction technique was used to test the microstructure of strap contactors with different deterioration states. The results showed that compared to the unused contactors, the contact resistance of the contactors under the combined effect of friction and high temperature increased 203.12 times and was in a failed state. During the process from unused state to wear deterioration, high temperature deterioration, and then to eventual failure of the contactors, the average grain size gradually grows from 8.15 μm to 25 μm, the dislocation density gradually decreases from 2.38 × 1014 m−2 to 1.04 × 1014 m−2, and there are a significant proportion of the recrystallized organization. These changes are detrimental to the mechanical properties of the contactors. In addition, the distribution of grain boundaries in the contact area proves the occurrence of over-temperature phenomenon in this area, which will accelerate the deterioration of the contactors and eventually lead to the failure of the component. The relevant conclusions can provide a theoretical basis for the design of electrical connection structure of strap contacts as well as the study of deterioration mechanism.
- 15 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (5) , 2776-2784
Insulation Degradation of Epoxy Resin Impregnated Paper Bushing Under Discharge Arc Ablation
Converter transformer valve side bushing is an irreplaceable key equipment in the UHVDC transmission project. In the process of operation, the surface of the epoxy resin impregnated paper (ERIP) core will produce partial discharge due to insulation defects, and the formed discharge arc will destroy the insulation layer, which seriously threatens the safe and stable operation of the valve side bushing. In this paper, an arc ablation experimental platform was built to study the thermal response characteristics of ERIP in SF 6 arc ablation. The surface microscopic morphology and dielectric properties of the samples before and after ablation were compared and analyzed, and the intrinsic mechanism of surface insulation failure was further revealed by a mathematical model. The results show that the huge heat generated by the arc discharge causes the decomposition of the epoxy resin, leading to the gradual increase of the internal porosity and permeability of the material, and the carbon layer structure will be formed on the surface after complete pyrolysis. With the increase of the arc action time, the ERIP is gradually transformed into carbide and pore products, the material surface resistance decreases, the roughness increases, and a local failure region is formed, which reduces the surface electrical properties of the material and ultimately leads to the failure of surface insulation.
- 15 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (5) , 2776-2784
Insulation Degradation of Epoxy Resin Impregnated Paper Bushing Under Discharge Arc Ablation
Converter transformer valve side bushing is an irreplaceable key equipment in the UHVDC transmission project. In the process of operation, the surface of the epoxy resin impregnated paper (ERIP) core will produce partial discharge due to insulation defects, and the formed discharge arc will destroy the insulation layer, which seriously threatens the safe and stable operation of the valve side bushing. In this paper, an arc ablation experimental platform was built to study the thermal response characteristics of ERIP in SF 6 arc ablation. The surface microscopic morphology and dielectric properties of the samples before and after ablation were compared and analyzed, and the intrinsic mechanism of surface insulation failure was further revealed by a mathematical model. The results show that the huge heat generated by the arc discharge causes the decomposition of the epoxy resin, leading to the gradual increase of the internal porosity and permeability of the material, and the carbon layer structure will be formed on the surface after complete pyrolysis. With the increase of the arc action time, the ERIP is gradually transformed into carbide and pore products, the material surface resistance decreases, the roughness increases, and a local failure region is formed, which reduces the surface electrical properties of the material and ultimately leads to the failure of surface insulation.
- Open Access
Research on the Characteristic of the Electrical Contact Resistance of Strap Contacts Used in High Voltage Bushings
As an important electrical connection component in electrical equipment, the strap contact is directly related to the long-term operation stability of equipment. The electrical contact resistance (ECR) of the electrical connection structure is an important indicator for evaluating the reliability of the electrical contact system. In this research, the theoretical calculation of ECR of the strap contacts used by the G-W theoretical model and the fractal theoretical model is improved and compared. After comparison with the experimental measurement values, the rationality and accuracy of the two theoretical models are discussed. The results show that when the load is small (1–3 N), the maximum error of G-W model is 41%, while the fractal model method has a maximum error of 9%. When the load is large (4–10 N), the results of the two are almost the same, and the errors are both within 14%. In summary, the error range of the fractal model is smaller and the change trend is closer to the experimental value, which is suitable for a relatively better ECR analytical calculation theory. The research results can provide a theoretical basis for research on the electrical contact performance of the electrical contact structure of electrical equipment.
Open AccessResearch on the Characteristic of the Electrical Contact Resistance of Strap Contacts Used in High Voltage Bushings
As an important electrical connection component in electrical equipment, the strap contact is directly related to the long-term operation stability of equipment. The electrical contact resistance (ECR) of the electrical connection structure is an important indicator for evaluating the reliability of the electrical contact system. In this research, the theoretical calculation of ECR of the strap contacts used by the G-W theoretical model and the fractal theoretical model is improved and compared. After comparison with the experimental measurement values, the rationality and accuracy of the two theoretical models are discussed. The results show that when the load is small (1–3 N), the maximum error of G-W model is 41%, while the fractal model method has a maximum error of 9%. When the load is large (4–10 N), the results of the two are almost the same, and the errors are both within 14%. In summary, the error range of the fractal model is smaller and the change trend is closer to the experimental value, which is suitable for a relatively better ECR analytical calculation theory. The research results can provide a theoretical basis for research on the electrical contact performance of the electrical contact structure of electrical equipment.