Adrienne Joyce Kosca
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Adrienne Joyce Kosca has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Ashley Mikhaela Tan
De La Salle University, Manila, Philippines
1 shared publication - Elmer Pamisa Dadios
Department of Manufacturing Engineering and Management, De La Salle University, Manila 1004, Philippines
1 shared publication - Homer Co
De La Salle University, Manila, Philippines
1 shared publication - Jason Espanola
De La Salle University, Manila, Philippines
1 shared publication - Joseph Rey H. Sta. Agueda
Department of Manufacturing Engineering and Management, De La Salle University, Manila 1004, Philippines
1 shared publication - Justine Clarice Tan
De La Salle University, Manila, Philippines
1 shared publication
Latest Publications
- Open Access
- 8 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 125-131
Automated Plantar Pressure Monitoring System for the Prevention of Diabetic Foot Ulcers Using Internet of Things (IoT)
— This paper presents an automated plantar pressure monitoring system using the Internet of Things (IoT) for early detection of diabetic foot ulcers (DFU). DFUs are common complications of diabetes that can negatively impact the life of a patient. Usual treatments for DFUs are drastic as they may include amputating the area affected, which is why this study aims to create a wearable foot device with a real-time monitoring system powered by the Internet of Things (IoT) to measure the plantar pressure experienced by the user. An important aspect of the prototype of this study is that it follows the three paradigms of intelligent manufacturing systems: sensing, smart, and sustainable. There will be force-sensitive resistors (FSR) to measure the plantar pressure and an LED to alert the user if an abnormal pressure is detected. Additionally, the smart feature will be represented by the IoT system that will notify the user if the plantar pressure experienced by the user exceeds the plantar threshold of 200 kPa. This system was made possible through the use of the Arduino IoT cloud, wherein the values of the FSRs and LED status can be monitored in the dashboard in real-time. The system will also automatically notify the user using the dashboard and by the LED, which turns red once any of the FSRs senses pressure greater than the threshold. To potentially help patients prevent DFUs from occurring, the prototype is designed to be a low-cost, non-disposable, reusable, and universal product.
- 8 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 125-131
Open AccessAutomated Plantar Pressure Monitoring System for the Prevention of Diabetic Foot Ulcers Using Internet of Things (IoT)
— This paper presents an automated plantar pressure monitoring system using the Internet of Things (IoT) for early detection of diabetic foot ulcers (DFU). DFUs are common complications of diabetes that can negatively impact the life of a patient. Usual treatments for DFUs are drastic as they may include amputating the area affected, which is why this study aims to create a wearable foot device with a real-time monitoring system powered by the Internet of Things (IoT) to measure the plantar pressure experienced by the user. An important aspect of the prototype of this study is that it follows the three paradigms of intelligent manufacturing systems: sensing, smart, and sustainable. There will be force-sensitive resistors (FSR) to measure the plantar pressure and an LED to alert the user if an abnormal pressure is detected. Additionally, the smart feature will be represented by the IoT system that will notify the user if the plantar pressure experienced by the user exceeds the plantar threshold of 200 kPa. This system was made possible through the use of the Arduino IoT cloud, wherein the values of the FSRs and LED status can be monitored in the dashboard in real-time. The system will also automatically notify the user using the dashboard and by the LED, which turns red once any of the FSRs senses pressure greater than the threshold. To potentially help patients prevent DFUs from occurring, the prototype is designed to be a low-cost, non-disposable, reusable, and universal product.