Michael Fromager
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michael Fromager has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Kamel Aït-Ameur
Centre de Recherche sur les Ions, les Matériaux et la Photonique (CIMAP), UMR6252 CEA-CNRS-ENSICAEN-Université de Caen, 6 Bd Maréchal Juin, CEDEX 4, F14050 Caen, France
2 shared publications - Abdelhalim Bencheikh
University of Mohamed El Bachir El Ibrahimi
1 shared publication - Abdelkrim Hasnaoui
Institut National d’Optométrie d’Ouled Fayet (INOOF), Résidence les Palmiers, Ouled Fayet, Algiers RW233, Algeria
1 shared publication - Sofiane Haddadi
Division Milieux Ionisés et Lasers
1 shared publication
Latest Publications
- Open Access
Intensity Profile Reshaping of a Spectrally Broadened Gaussian Beam
Research into the spatial reshaping of monochromatic laser beams grew significantly in the late 1990s due to improvements in the fabrication of diffractive optical elements. Nowadays, some applications, such as optical coherence tomography, necessitate the use of broadband light beams with a spectral width of hundreds of nanometers. The difficulty in reshaping such spectrally broadened beams lies in the wavelength dependence of the beam shaping process. This paper presents a numerical study of the wavelength dependence of two beam shaping techniques that allow a Gaussian beam to be transformed into a flat-top or doughnut intensity profile in the focal plane of a focusing lens. The first technique is based on the diffraction of an incident Gaussian beam passing through a simple binary diffractive optical element. The second technique can be described as an interferometric method, as it involves the coaxial superposition of two Gaussian beams emerging from a Michelson interferometer. We compared the stability of these two techniques’ ability to reshape the beam versus the spectral bandwidth of the incident Gaussian beam. We showed that the interferometric method is more resilient than the diffractive method to changes in the spectral bandwidth of the Gaussian beam. We also considered the case of a quasi-monochromatic beam delivered by a widely tunable laser and reshaped using the interferometric method, where the dispersion of beam reshaping could be mitigated by two programmable liquid lenses that enable control of the curvature of the Michelson interferometer mirrors.
Open AccessIntensity Profile Reshaping of a Spectrally Broadened Gaussian Beam
Research into the spatial reshaping of monochromatic laser beams grew significantly in the late 1990s due to improvements in the fabrication of diffractive optical elements. Nowadays, some applications, such as optical coherence tomography, necessitate the use of broadband light beams with a spectral width of hundreds of nanometers. The difficulty in reshaping such spectrally broadened beams lies in the wavelength dependence of the beam shaping process. This paper presents a numerical study of the wavelength dependence of two beam shaping techniques that allow a Gaussian beam to be transformed into a flat-top or doughnut intensity profile in the focal plane of a focusing lens. The first technique is based on the diffraction of an incident Gaussian beam passing through a simple binary diffractive optical element. The second technique can be described as an interferometric method, as it involves the coaxial superposition of two Gaussian beams emerging from a Michelson interferometer. We compared the stability of these two techniques’ ability to reshape the beam versus the spectral bandwidth of the incident Gaussian beam. We showed that the interferometric method is more resilient than the diffractive method to changes in the spectral bandwidth of the Gaussian beam. We also considered the case of a quasi-monochromatic beam delivered by a widely tunable laser and reshaped using the interferometric method, where the dispersion of beam reshaping could be mitigated by two programmable liquid lenses that enable control of the curvature of the Michelson interferometer mirrors.
- Open Access
- 18 March 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (6) , 3331
Numerical Simulation of an Optical Resonator for the Generation of Radial Laguerre–Gauss LGp0 Modes
The research on high-order transverse modes in lasers is a subject as old as the laser itself and has been largely abandoned. However, recently several studies have demonstrated an interest in using, instead of the usual Gaussian beam, a radial Laguerre–Gauss LGp0 beam, as, for instance, one can observe a strong improvement, for a given power, in the longitudinal and radial forces in optical tweezers illuminated by a LGp0 beam instead of the usual Gaussian beam. Since in most commercial lasers, the delivered laser beam is Gaussian, we therefore think it opportune to consider the problems of forcing a laser to oscillate individually on a higher-order transverse LGp0 mode. We propose a comprehensive analysis of the effects of an intra-cavity phase or amplitude mask on the fundamental mode of a plano-concave cavity. In particular, we discuss the best choice of parameters favouring the fundamental mode of a pure radial Laguerre–Gauss LGp0 model.
- 18 March 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (6) , 3331
Open AccessNumerical Simulation of an Optical Resonator for the Generation of Radial Laguerre–Gauss LGp0 Modes
The research on high-order transverse modes in lasers is a subject as old as the laser itself and has been largely abandoned. However, recently several studies have demonstrated an interest in using, instead of the usual Gaussian beam, a radial Laguerre–Gauss LGp0 beam, as, for instance, one can observe a strong improvement, for a given power, in the longitudinal and radial forces in optical tweezers illuminated by a LGp0 beam instead of the usual Gaussian beam. Since in most commercial lasers, the delivered laser beam is Gaussian, we therefore think it opportune to consider the problems of forcing a laser to oscillate individually on a higher-order transverse LGp0 mode. We propose a comprehensive analysis of the effects of an intra-cavity phase or amplitude mask on the fundamental mode of a plano-concave cavity. In particular, we discuss the best choice of parameters favouring the fundamental mode of a pure radial Laguerre–Gauss LGp0 model.