Kyota Yoshinaga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kyota Yoshinaga has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Takashi Kimura
The University of Tokyo
4 shared publications - Jordan Tyler O'NEal
Stanford PULSE Institute, SLAC National Accelerator Laboratory, Menlo Park, USA
3 shared publications Noboru Furuya
3 shared publications- Haruhiko Ohashi
Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5198, Japan
2 shared publications Hidekazu Mimura
The University of Tokyo
2 shared publicationsKai Sakurai
The University of Tokyo
2 shared publications
Latest Publications
- 23 June 2026
- Published by Optica Publishing Group in Optica
- Vol. 13 (8) , 1643
Femtosecond hyperspectral imaging with single-shot X-ray pulse
Single-shot hyperspectral imaging was demonstrated in the soft X-ray region by combining a multi-aperture grating (MAG) with Wolter-mirror microscopy. The MAG simultaneously segments the magnified image into 417 spatial channels and disperses each channel onto a two-dimensional detector. This system functions as a dispersive spectrometer with two-dimensional spatial sampling, obtaining absorption spectra at each point of the magnified image in a single pulse. At SACLA BL1, a field of view of 39µm×39µm was obtained, and a spatial sampling of 2.4µm(H)×1.6µm(V), defined by the MAG aperture pitch, was achieved. A grating-limited spectral resolving power of E/ΔE≈10 3 around 100 eV was theoretically estimated, limited by the grating line count per aperture. The system is applied to shot-to-shot measurements of the spatially resolved beam spectrum and to single-shot spectro-microscopy of a silicon nitride thin film near its absorption edge. These results establish a route to chemical-state-sensitive imaging of heterogeneous and potentially non-repeatable samples.
- 23 June 2026
- Published by Optica Publishing Group in Optica
- Vol. 13 (8) , 1643
Femtosecond hyperspectral imaging with single-shot X-ray pulse
Single-shot hyperspectral imaging was demonstrated in the soft X-ray region by combining a multi-aperture grating (MAG) with Wolter-mirror microscopy. The MAG simultaneously segments the magnified image into 417 spatial channels and disperses each channel onto a two-dimensional detector. This system functions as a dispersive spectrometer with two-dimensional spatial sampling, obtaining absorption spectra at each point of the magnified image in a single pulse. At SACLA BL1, a field of view of 39µm×39µm was obtained, and a spatial sampling of 2.4µm(H)×1.6µm(V), defined by the MAG aperture pitch, was achieved. A grating-limited spectral resolving power of E/ΔE≈10 3 around 100 eV was theoretically estimated, limited by the grating line count per aperture. The system is applied to shot-to-shot measurements of the spatially resolved beam spectrum and to single-shot spectro-microscopy of a silicon nitride thin film near its absorption edge. These results establish a route to chemical-state-sensitive imaging of heterogeneous and potentially non-repeatable samples.
- Open Access
- 19 May 2026
- Published by American Physical Society (APS) in APS Open Science
- Vol. 1
Quantitative imaging of spin and orbital magnetic moments in subsurface ultrathin layer with soft x-ray dichroic spectroptychography
Quantitative evaluation of magnetic moment distributions in microstructures with high spatial resolution is essential to advance the development of next-generation spintronic devices. In this study, we successfully imaged the magnetic domain structure of micropatterned subnanometer thin films by combining high-resolution and high-sensitivity imaging using soft x-ray ptychography and x-ray magnetic circular dichroism. Furthermore, by measuring hyperspectral images of magnetic thin-film patterns and applying the sum rule to absorption spectra at each pixel of the image, quantitative two-dimensional measurements of spin and orbital magnetic moments within magnetic domains were achieved. Such measurements provide a powerful evaluation method for the design of devices based on physical phenomena such as spin and orbital currents.
- 19 May 2026
- Published by American Physical Society (APS) in APS Open Science
- Vol. 1
Open AccessQuantitative imaging of spin and orbital magnetic moments in subsurface ultrathin layer with soft x-ray dichroic spectroptychography
Quantitative evaluation of magnetic moment distributions in microstructures with high spatial resolution is essential to advance the development of next-generation spintronic devices. In this study, we successfully imaged the magnetic domain structure of micropatterned subnanometer thin films by combining high-resolution and high-sensitivity imaging using soft x-ray ptychography and x-ray magnetic circular dichroism. Furthermore, by measuring hyperspectral images of magnetic thin-film patterns and applying the sum rule to absorption spectra at each pixel of the image, quantitative two-dimensional measurements of spin and orbital magnetic moments within magnetic domains were achieved. Such measurements provide a powerful evaluation method for the design of devices based on physical phenomena such as spin and orbital currents.
- Open Access
- 14 April 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (3) , 604-608
Total-reflection-based microscope compatible with X-ray and visible light for sample positioning
Sample positioning in X-ray imaging is often technically demanding and involves radiation exposure to the sample. For easier and damage-free positioning, the integration of a visible-light microscope is an effective and widely adopted approach. However, such visible-light microscopes require careful calibration of the objective optic against the X-ray microscope, which introduces additional challenges. To address this issue, we propose a simple total-reflection-based microscope compatible with X-rays and visible light using a Wolter mirror which functions as both X-ray condenser optic and visible-light objective optic. Calibrating our visible-light microscope requires only simple adjustment of an optical lens and three planar mirrors, while no adjustment of the objective optic. We constructed our proposed system for a soft X-ray ptychography system and successfully demonstrated the simple calibration of the visible-light microscope, which was then applied to position a biological sample without delivering a radiation dose.
- 14 April 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (3) , 604-608
Open AccessTotal-reflection-based microscope compatible with X-ray and visible light for sample positioning
Sample positioning in X-ray imaging is often technically demanding and involves radiation exposure to the sample. For easier and damage-free positioning, the integration of a visible-light microscope is an effective and widely adopted approach. However, such visible-light microscopes require careful calibration of the objective optic against the X-ray microscope, which introduces additional challenges. To address this issue, we propose a simple total-reflection-based microscope compatible with X-rays and visible light using a Wolter mirror which functions as both X-ray condenser optic and visible-light objective optic. Calibrating our visible-light microscope requires only simple adjustment of an optical lens and three planar mirrors, while no adjustment of the objective optic. We constructed our proposed system for a soft X-ray ptychography system and successfully demonstrated the simple calibration of the visible-light microscope, which was then applied to position a biological sample without delivering a radiation dose.
- Open Access
- 27 January 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (4)
Chemical-state imaging of a mammalian cell through multi-elemental soft x-ray spectro-ptychography
Soft x-ray spectro-ptychography is a high-resolution chemical state imaging technique and has significant potential for the analysis of light-element-rich samples such as biological cells. We measured hyperspectral images of a whole mammalian neuronal cell at the nitrogen and oxygen absorption edges with soft x rays using the achromatic ptychography system CARROT developed at SPring-8 BL07LSU. We visualized and classified the intracellular structures based on the difference of chemical states, which are difficult to recognize in a monochromatic image. The method is expected to give insight into the relationship between intracellular structures and chemical states.
- 27 January 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (4)
Open AccessChemical-state imaging of a mammalian cell through multi-elemental soft x-ray spectro-ptychography
Soft x-ray spectro-ptychography is a high-resolution chemical state imaging technique and has significant potential for the analysis of light-element-rich samples such as biological cells. We measured hyperspectral images of a whole mammalian neuronal cell at the nitrogen and oxygen absorption edges with soft x rays using the achromatic ptychography system CARROT developed at SPring-8 BL07LSU. We visualized and classified the intracellular structures based on the difference of chemical states, which are difficult to recognize in a monochromatic image. The method is expected to give insight into the relationship between intracellular structures and chemical states.