DLDan Luca

Dan Luca

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dan Luca has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Micro-Ultrasound Sagittal Length to Predict Clinically Significant Prostate Cancer in Lesions Visible on Both MRI and Micro-Ultrasound (Dual-Image Visible Lesions)

    by Francis Nguyen, Dan Luca, Kevin Walsh, Ailene Corona, William Chen, Seryn Ma, Ankush Sachdeva, Qi Miao, Steve Raman, Anthony Sisk, et al.

    Purpose: Dual-imaging visible prostate lesions (Prostate Imaging Reporting and Data System [PI-RADS] ≥ 4 and Prostate Risk Identification Using Micro-Ultrasound [PRI-MUS] ≥ 4) demonstrate high sensitivity for Grade Group (GG) ≥ 2 cancer but limited positive predictive value (PPV). We evaluated whether micro-ultrasound sagittal lesion length improves the prediction of GG ≥ 2 cancer in this high-risk population. Materials and Methods: We retrospectively analyzed 273 MRI/micro-ultrasound concordant lesions from men undergoing targeted prostate biopsy. All lesions were PI-RADS ≥ 4 and PRI-MUS ≥ 4. Maximal sagittal lesion length was measured on micro-ultrasound. PPV for GG ≥ 2 disease was calculated across 0.1 cm length thresholds. Logistic regression quantified the association between sagittal length and GG ≥ 2 cancer. GG distributions were compared across 0.5 cm length bins using χ 2 analysis. Results: Baseline PPV for dual-imaging visible lesions was 72.6%. A sagittal length threshold ≥ 2.1 cm yielded a PPV of 91.6%. All lesions ≥ 3.0 cm harbored GG ≥ 2 cancer (n = 9). On univariate analysis, each 1 cm increase in sagittal length was associated with an 8.7% increase in the odds of GG ≥ 2 disease ( P = .002) , whereas sagittal length on multivariate analysis was not independently associated with GG ≥ 2 after adjusting for PSA density, PI-RADS, and PRI-MUS ( P = .311). Although longer lesions were associated with higher GGs ( P = .031), substantial overlap in lesion size limited discrimination of specific tumor grades at a specific length threshold. Conclusions: In dual-imaging visible lesions, micro-ultrasound sagittal length has potential to provide incremental risk stratification for GG ≥ 2 prostate cancer. A threshold of approximately 2 cm confers > 90% PPV, offering a practical, real-time metric to refine risk assessment during targeted biopsy.

  • A Histopathologic Assessment of Prostate Ductal Anatomy in Relation to Micro-ultrasound

    by Dan Luca, Jake W. Pensa, Anoush K. Rehmani, Rory Geoghegan, Derrick Ushko, Griffith Hughes, Adam Kinnaird, David Kuppermann, Anthony Sisk, Kevin J. Walsh, et al.


  • Open Access

    Micro‐ultrasound tissue echogenicity predicts prostate cancer grade

    by Ailene E. Corona, Dan Luca, Kian Kolahi Sohrabi, Kyla Grunden, William Chen, Pooneh J. Sarmadian, Kevin J. Walsh, Lorna Kwan, Qi Miao, Kyung Sung, et al.

    Objectives: This study aimed to evaluate the association between lesion echogenicity on micro‐ultrasound (micro‐US) and the presence and grade of prostate cancer. Patients and Methods: We prospectively analysed 229 prostate lesions from 181 men undergoing micro‐US‐guided transperineal biopsy at UCLA. Lesions were visually graded as hyperechoic, isoechoic or hypoechoic relative to the central zone, which served as an internal reference due to its consistent tissue characteristics and low malignancy risk. Biopsy targeting was confirmed by visualizing the needle tract within the lesion. The primary outcome was the detection rate of Grade Group (GG) ≥ 2 cancer across echogenicity categories. Secondary analyses included associations with PSA density and MRI‐derived apparent diffusion coefficient (ADC) values, given that ADC is associated with tissue cellularity. Statistical comparisons were performed using chi‐square and Kruskal–Wallis tests, with post hoc pairwise analyses where appropriate. Results: GG ≥ 2 cancer detection rates increased with decreasing echogenicity: 22% in hyperechoic, 56.2% in isoechoic and 62.4% in hypoechoic lesions ( p < 0.01). Hypoechoic lesions also exhibited a higher proportion of GG ≥ 3 cancers ( p < 0.05). ADC values declined progressively from hyperechoic to hypoechoic lesions (median: 980, 851 and 751, respectively; p < 0.01), suggesting higher tissue cellularity. Regression analysis demonstrated no meaningful interaction between PRI‐MUS and echogenicity. PSA density did not significantly differ among echogenicity groups. Conclusions: Lesion hypoechogenicity on micro‐US is strongly associated with higher grade prostate cancer and lower ADC values, suggesting a link to tissue cellularity. These findings support the incorporation of echogenicity as a diagnostic marker within the micro‐US PRI‐MUS framework, potentially enhancing the accuracy of prostate cancer risk stratification.


  • Open Access

    Patient Educational Videos Delivered With Prostate Pathology Results Improve Knowledge and Satisfaction

    by Kian Kolahi Sohrabi, Ailene E. Corona, Dan Luca, Ashley Michel, William Chen, Kyla Grunden, Jonathan Bergman, Wayne G. Brisbane

    Background: Prostate biopsy pathology reports are often too complex for patients to interpret, despite their role in diagnosis and treatment decisions. We developed an instructional video to improve patient understanding of the biopsy report. We then evaluated the video’s impact on patient anxiety, satisfaction, and comprehension. Methods: On the day of the biopsy, we presented 11 prostate cancer patients with a mock pathology report standardized for a patient: Mickey Mouse. Subsequently, we evaluated their understanding of the report as well as their anxiety, satisfaction, and comprehension. Approximately, a week later, patients received their actual biopsy report, along with a supplemental educational video explaining it. Reusing the prior survey, we re‐evaluated patients understanding of their report, anxiety,and satisfaction. Results: Eleven patients completed the baseline survey, with a 45% response rate to the follow‐up survey. Before presenting the educational video, only 55% of participants accurately identified “Mickey Mouse’s” cancer status and Gleason score. After watching the educational video ( https://www.youtube.com/watch?v=c2e1VhhaUWc ) and receiving their biopsy reports, 100% of patients accurately identified their cancer status and Gleason score ( p = 0.12 for cancer status and p = 0.12 for Gleason score). Patient satisfaction significantly increased (higher value corresponds to higher satisfaction, mean = 2.64 vs mean = 3.7, p = 0.015), along with patient understanding of next steps of care improving (mean = 1.9 vs mean = 3, p = 0.077) following review of the video. We identified an increase of anxiety (mean = 2.36 vs mean = 2.4, p = 0.90) when patients reviewed their own pathology report. Among the five patients who completed both the initial and follow‐up surveys, there we noted similar trends to those noted above, however, due to the smaller sample size the results were no longer statistically significant. Conclusions: Pathology reports are difficult to interpret. Providing patients with report specific explanatory videos improved comprehension, and satisfaction. Our results are a preliminary proof of concept evaluation; however, given the low cost and ease of implementation, we feel that video explanation deserves further evaluation.

  • Open Access

    Using Sagittal Length to Differentiate Between PRI-MUS 4 and PRI-MUS 5 Lesions

    by Dan Luca, Ailene E. Corona, Kevin Walsh, Kyla Grunden, Anissa V. Bailey, Anthony Sisk, Kyung Sung, Wayne G. Brisbane

    Purpose: Micro-ultrasound (micro-US) has been shown to have equivalent prostate cancer detection to MRI. However, unlike Prostate Imaging Reporting and Data System (PI-RADS), the PRI-MUS system does not use tumor size to distinguish between 4 and 5 lesions. Reliance solely on acoustic features may lead to variability in interpretation among operators and suboptimal cancer detection rates. In this study, we aimed to evaluate whether sagittal length improves the cancer detection rates for PRI-MUS 4 and 5 lesions. Materials and Methods: We evaluated 275 PRI-MUS 5 and 5 lesions from men who underwent micro-ultrasound–guided biopsy at the University of California, Los Angeles (UCLA) medical center. Micro-US sagittal length was used as a differentiating factor between PRI-MUS 4 and 5 lesions by determining the Positive predictive value (PPV) at multiple thresholds. Chi-square analysis was used to compare the PPV of PRI-MUS version1 (V1) and PRI-MUS version2 (V2) for Grade Group ≥ 2 prostate cancer. Results: PPV of micro-US for PRI-MUS V1 4 and 5 lesions was 50.9% and 85.5%, respectively. Using a threshold of 2 cm, the PPV of micro-US for the PRI-MUS V2 4 and 5 scoring system was 60.3% and 88.4%. This corresponds to a slight increase of 2.9% in PPV for lesions with a score of 5 and a 9.4% increase for lesions assigned a PRI-MUS score of 4 ( P = .06). Conclusion: This study proposes sagittal length as an objective criterion for lesion classification, with a threshold of 2.0 cm for PRI-MUS 5 upgrading. This approach improves the PPV of PRI-MUS 4 lesions by approximately 10% while preserving the PPV of PRI-MUS 5 lesions.


  • Open Access

    Combining Prostate MRI and Microultrasound to Omit Systematic Biopsy

    by Dan Luca, Arkaprava Roy, Jake W. Pensa, Rani Ashouri, Brianna Nguyen, Kevin J. Walsh, Zhongyue Zhang, Joseph R. Grajo, Sara Moscovita Falzarano, Padraic G. O'MAlley, et al.

    Purpose: The diagnosis of prostate cancer often includes MRI-guided biopsy. Many surgeons perform targeted and systematic biopsies to compensate for registration errors between MRI and conventional ultrasound (5-7 mHz). Using 29 mHz, microultrasound visualizes prostate cancers, enabling visual confirmation of target sampling. We sought to evaluate whether an MRI + microultrasound targeted biopsy could omit systematic biopsy. Methods: We retrospectively evaluated 155 men undergoing transperineal prostate biopsy at the University of Florida. Eighty-three men met inclusion criteria: MRI prior, microultrasound guidance, and targeted and systematic biopsy. The MRI target was visualized with microultrasound and biopsied. We graded each region of interest (ROI) using Prostate Imaging Reporting & Data System (PI-RADS) and Prostate Risk Identification using Micro-Ultrasound (PRI-MUS) scores. We considered cores containing Grade Group ≥ 2 (GG ≥ 2) as clinically significant prostate cancer. The primary endpoint was the GG ≥ 2 cancer detection rate (CDR = GG ≥ 2 targeted cores/GG ≥ 2 all cores). Results: Patients with PI-RADS and PRI-MUS scores ≥ 3 had a targeted-only CDR of 93.3%. Those with scores ≥ 4 (dual imaging visible) had a CDR of 97.4%. Systematic without targeted cores had CDR of 61.5%. One patient (1.2%) had GG ≥ 2 detected on systematic biopsy alone. Area under the curve (AUC) values for PI-RADS, PRI-MUS, and dual imaging visible lesions were 0.73, 0.69, and 0.73, respectively (P = NS). Conclusions: Only 1 patient, with a dual imaging visible ROI, had GG ≥ 2 detected on systematic biopsy but not in the ROI. Otherwise, > 97% of clinically significant prostate cancer were detected with targeted biopsies alone. In dual imaging visible ROIs, surgeons may consider omitting systematic biopsy.