Tomasz Glawdel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tomasz Glawdel has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Carolyn L. Ren
University of Waterloo
5 shared publications - Janusz Pawliszyn
University of Waterloo
2 shared publications Junjie Ou
Department of Chemistry, University of Waterloo, Waterloo, Ontario, CanadaN2L 3G1
2 shared publications- Zeyad Almutairi
Sustainable Energy Technology Center, King Saud University, Riyadh 11421, Saudi Arabia
2 shared publications - Caglar Elbuken
Faculty of Biochemistry and Molecular Medicine, University of Oulu, Oulu, Finland
1 shared publication - David A. Johnson
University of Waterloo
1 shared publication
Latest Publications
- 15 September 2009
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (22) , 3243-3250
Microfluidic system with integrated electroosmotic pumps, concentration gradient generator and fish cell line (RTgill-W1)—towards water toxicity testing
This study presents a microfluidic system that incorporates electroosmotic pumps, a concentration gradient generator and a fish cell line (rainbow trout gill) to perform toxicity testing on fish cells seeded in the system. The system consists of three mechanical components: (1) a toxicity testing chip containing a microfluidic gradient generator which creates a linear concentration distribution of toxicant in a cell test chamber, (2) an electroosmotic (EO) pump chip that controls the flow rate and operation of the toxicity chip, and (3) indirect reservoirs that connect the two chips allowing for the toxicant solution to be pumped separately from the electroosmotic pump solution. The flow rate and stability of the EO pumps was measured and tested by monitoring the gradient generator using fluorescence microscopy. Furthermore, a lethality test was performed with this system setup using a rainbow trout gill cell line (RTgill-W1) as the test cells and sodium dodecyl sulfate as a model toxicant. A gradient of sodium dodecyl sulfate, from 0 to 50 µg mL−1, was applied for 1 hr to the attached cells, and the results were quantified using a Live/DeadTMcell assay. This work is a preliminary study on the application of EO pumps in a living cell assay, with the potential to use the pumps in portable water quality testing devices with RTgill-W1 cells as the biosensors.
- 15 September 2009
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (22) , 3243-3250
Microfluidic system with integrated electroosmotic pumps, concentration gradient generator and fish cell line (RTgill-W1)—towards water toxicity testing
This study presents a microfluidic system that incorporates electroosmotic pumps, a concentration gradient generator and a fish cell line (rainbow trout gill) to perform toxicity testing on fish cells seeded in the system. The system consists of three mechanical components: (1) a toxicity testing chip containing a microfluidic gradient generator which creates a linear concentration distribution of toxicant in a cell test chamber, (2) an electroosmotic (EO) pump chip that controls the flow rate and operation of the toxicity chip, and (3) indirect reservoirs that connect the two chips allowing for the toxicant solution to be pumped separately from the electroosmotic pump solution. The flow rate and stability of the EO pumps was measured and tested by monitoring the gradient generator using fluorescence microscopy. Furthermore, a lethality test was performed with this system setup using a rainbow trout gill cell line (RTgill-W1) as the test cells and sodium dodecyl sulfate as a model toxicant. A gradient of sodium dodecyl sulfate, from 0 to 50 µg mL−1, was applied for 1 hr to the attached cells, and the results were quantified using a Live/DeadTMcell assay. This work is a preliminary study on the application of EO pumps in a living cell assay, with the potential to use the pumps in portable water quality testing devices with RTgill-W1 cells as the biosensors.
- 26 March 2009
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (13) , 1926-1932
Fabrication of a hybrid PDMS/SU-8/quartz microfluidic chip for enhancing UV absorption whole-channel imaging detection sensitivity and application for isoelectric focusing of proteins
A poly(dimethylsiloxane)(PDMS)/SU-8/quartz hybrid chip was developed and applied in the isoelectric focusing (IEF) of proteins with ultraviolet (UV) absorbance-based whole-channel imaging detection (UV-WCID). Each hybrid chip was made of three layers: a PDMS flat top substrate, a bottom quartz substrate and a middle layer of SU-8 photoresist. The SU-8 serves two purposes: it contains the microchannel used for IEF separation, and acts as an optical slit that absorbs UV light below 300 nm improving detection sensitivity in WCID. The novel hybrid design demonstrates a two to three times improvement in sensitivity over a comparable PDMS/PDMS design. In addition, the hybrid chip exhibits increased heat dissipation due to the superior thermal conductivity of the bottom quartz substrate allowing for larger electric fields to be used in separations. The hybrid design with IEF-UV-WCID was successful in resolving a complicated sample, hemoglobin control, with high fidelity.
- 26 March 2009
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (13) , 1926-1932
Fabrication of a hybrid PDMS/SU-8/quartz microfluidic chip for enhancing UV absorption whole-channel imaging detection sensitivity and application for isoelectric focusing of proteins
A poly(dimethylsiloxane)(PDMS)/SU-8/quartz hybrid chip was developed and applied in the isoelectric focusing (IEF) of proteins with ultraviolet (UV) absorbance-based whole-channel imaging detection (UV-WCID). Each hybrid chip was made of three layers: a PDMS flat top substrate, a bottom quartz substrate and a middle layer of SU-8 photoresist. The SU-8 serves two purposes: it contains the microchannel used for IEF separation, and acts as an optical slit that absorbs UV light below 300 nm improving detection sensitivity in WCID. The novel hybrid design demonstrates a two to three times improvement in sensitivity over a comparable PDMS/PDMS design. In addition, the hybrid chip exhibits increased heat dissipation due to the superior thermal conductivity of the bottom quartz substrate allowing for larger electric fields to be used in separations. The hybrid design with IEF-UV-WCID was successful in resolving a complicated sample, hemoglobin control, with high fidelity.
- 20 October 2008
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (1) , 171-174
Photobleaching absorbed Rhodamine B to improve temperature measurements in PDMS microchannels
Rhodamine B based fluorescence thermometry is commonly used in microfluidics to measure fluid temperatures in microchannels. Notable absorption of Rhodamine B into PDMS channel walls, however, causes difficulties in obtaining accurate temperature measurements due to a steady increase in the overall fluorescent signal. A simple and effective technique is reported that removes the fluorescent signal from absorbed Rhodamine B dye by means of photobleaching with a high intensity light source before taking images for thermometry analysis. The temperature field at the convergence of hot and cold streams in a Y-channel fabricated in PDMS/glass microfluidic chip is studied to demonstrate the execution of the photobleaching technique.
- 20 October 2008
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (1) , 171-174
Photobleaching absorbed Rhodamine B to improve temperature measurements in PDMS microchannels
Rhodamine B based fluorescence thermometry is commonly used in microfluidics to measure fluid temperatures in microchannels. Notable absorption of Rhodamine B into PDMS channel walls, however, causes difficulties in obtaining accurate temperature measurements due to a steady increase in the overall fluorescent signal. A simple and effective technique is reported that removes the fluorescent signal from absorbed Rhodamine B dye by means of photobleaching with a high intensity light source before taking images for thermometry analysis. The temperature field at the convergence of hot and cold streams in a Y-channel fabricated in PDMS/glass microfluidic chip is studied to demonstrate the execution of the photobleaching technique.
- 7 August 2008
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 8 (10) , 1738-1741
Side-by-side comparison of disposable microchips with commercial capillary cartridges for application in capillary isoelectric focusing with whole column imaging detection
Simple-structured, well-functioned disposable poly(dimethylsiloxane) (PDMS) microchips were developed for capillary isoelectric focusing with whole column imaging detection (CIEF-WCID). Side-by-side comparison of the developed microchips with well-established commercial capillary cartridges demonstrated that the disposable microchips have comparable performance as well as advantages such as absence of lens effect and possibility of high-aspect-ratio accompanied with a dramatic reduction in cost.
- 7 August 2008
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 8 (10) , 1738-1741
Side-by-side comparison of disposable microchips with commercial capillary cartridges for application in capillary isoelectric focusing with whole column imaging detection
Simple-structured, well-functioned disposable poly(dimethylsiloxane) (PDMS) microchips were developed for capillary isoelectric focusing with whole column imaging detection (CIEF-WCID). Side-by-side comparison of the developed microchips with well-established commercial capillary cartridges demonstrated that the disposable microchips have comparable performance as well as advantages such as absence of lens effect and possibility of high-aspect-ratio accompanied with a dramatic reduction in cost.
- 25 June 2008
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 6 (2) , 241-251
A Y-channel design for improving zeta potential and surface conductivity measurements using the current monitoring method
- 25 June 2008
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 6 (2) , 241-251
A Y-channel design for improving zeta potential and surface conductivity measurements using the current monitoring method