Juyoung Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Juyoung Lee has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Sangho Lee
School of Civil and Environmental Engineering, Kookmin University, 77 Jeongneung-ro, Seongbuk-gu, Seoul 02707, Republic of Korea
3 shared publications - Seoyeon Lee
School of Civil and Environmental Engineering, Kookmin University, 77 Jeongneung-ro, Seongbuk-gu, Seoul 02707, Republic of Korea
2 shared publications - Yongjun Choi
School of Civil and Environmental Engineering, Kookimin University, 77 Jeongneung-ro, Seongbuk-gu, Seoul 02707, Republic of Korea
2 shared publications - Hyeongrak Cho
School of Civil and Environmental Engineering, Kookmin University, 77, Jeongneung-ro, Seongbuk-gu, Seoul 02707, Republic of Korea
1 shared publication - Jaehyun Ju
Korea Testing Laboratory, 10, Chungui-ro, Jinju-si 52852, Republic of Korea
1 shared publication - Jinsu Park
Jinsung ENC Co., Ltd., 46 Nonggongdanji-gil, Goa-eup, Gumi-si 39137, Gyeongsangbuk-do, Republic of Korea
1 shared publication
Latest Publications
- Open Access
Performance Analysis and Optimization of a Membrane Capacitive Deionization Process for Lithium Enrichment from Lithium-Ion Battery Wastewater
The rapid growth of lithium-ion battery (LIB) manufacturing has increased the generation of wastewater containing lithium and transition metals, creating a need for selective recovery processes with minimal chemical use. This study evaluated membrane capacitive deionization (MCDI) with a monovalent-selective cation-exchange membrane (MS-CEM) for lithium enrichment from simulated LIB manufacturing wastewater. One-factor-at-a-time experiments and response surface methodology were used to identify key operating parameters and optimize their interactions. Under the optimized conditions (1.43 V, pH 4.48, sorption time 500 s), the system achieved a lithium enrichment factor of 2.54 and a Li+/M2+ selectivity coefficient of 4.71. Over 100 cycles (approximately 28 h), these values decreased to 2.15 and 2.17, respectively. SEM–EDS detected Ni-, Co- and Mn-containing deposits on the spacer, electrodes and ion-exchange membranes, consistent with transition-metal fouling, although the deposit phases were not determined. A single cleaning with 0.01 M EDTA followed by 0.01 M HCl restored the selectivity coefficient to 4.38 and the enrichment factor to 2.25. These results indicate the potential of MS-CEM-assisted MCDI as a selective lithium pre-concentration step prior to hydrometallurgical recovery and identify selectivity loss, which coincided with transition-metal deposition, as the main limitation to sustained operation.
Open AccessPerformance Analysis and Optimization of a Membrane Capacitive Deionization Process for Lithium Enrichment from Lithium-Ion Battery Wastewater
The rapid growth of lithium-ion battery (LIB) manufacturing has increased the generation of wastewater containing lithium and transition metals, creating a need for selective recovery processes with minimal chemical use. This study evaluated membrane capacitive deionization (MCDI) with a monovalent-selective cation-exchange membrane (MS-CEM) for lithium enrichment from simulated LIB manufacturing wastewater. One-factor-at-a-time experiments and response surface methodology were used to identify key operating parameters and optimize their interactions. Under the optimized conditions (1.43 V, pH 4.48, sorption time 500 s), the system achieved a lithium enrichment factor of 2.54 and a Li+/M2+ selectivity coefficient of 4.71. Over 100 cycles (approximately 28 h), these values decreased to 2.15 and 2.17, respectively. SEM–EDS detected Ni-, Co- and Mn-containing deposits on the spacer, electrodes and ion-exchange membranes, consistent with transition-metal fouling, although the deposit phases were not determined. A single cleaning with 0.01 M EDTA followed by 0.01 M HCl restored the selectivity coefficient to 4.38 and the enrichment factor to 2.25. These results indicate the potential of MS-CEM-assisted MCDI as a selective lithium pre-concentration step prior to hydrometallurgical recovery and identify selectivity loss, which coincided with transition-metal deposition, as the main limitation to sustained operation.
- Open Access
Analysis of Contaminant Behavior in Loop Pipe System for Ultrapure Water Distribution Using Computational Fluid Dynamics and Autopsy
Ultrapure water (UPW) distribution loops must deliver stable hydraulics while limiting contamination from polymer piping. This study integrates computational fluid dynamics (CFD) with systematic pipe autopsy to examine contaminant behavior in a pilot-scale UPW loop constructed using chlorinated polyvinyl chloride (CPVC) and polyvinylidene fluoride (PVDF) and operated under identical conditions. CFD predicted nearly identical loop-scale velocity, pressure, and temperature fields for both materials, and identified low-shear recirculation at elbows and downstream tees as zones of elevated particle residence. Lagrangian particle tracking (0.05 μm, no-sticking) showed rapid breakthrough and complete flushing within 13 min, providing a hydraulic susceptibility map for transient retention. After eight months of operation, 17 sections were inspected endoscopically and leached at 60 °C. CPVC exhibited yellow–brown discoloration and highly heterogeneous total organic carbon (TOC) release with hot spots of 16–18 mg·L−1, whereas PVDF showed low, spatially uniform TOC (0.4–2.3 mg·L−1) and minimal fouling; inorganic ions remained at sub-mg·L−1 levels for both materials. Overall, geometry governs where contamination can accumulate, while material properties control its magnitude and persistence, with PVDF providing greater resistance to long-term organic contamination than CPVC.
Open AccessAnalysis of Contaminant Behavior in Loop Pipe System for Ultrapure Water Distribution Using Computational Fluid Dynamics and Autopsy
Ultrapure water (UPW) distribution loops must deliver stable hydraulics while limiting contamination from polymer piping. This study integrates computational fluid dynamics (CFD) with systematic pipe autopsy to examine contaminant behavior in a pilot-scale UPW loop constructed using chlorinated polyvinyl chloride (CPVC) and polyvinylidene fluoride (PVDF) and operated under identical conditions. CFD predicted nearly identical loop-scale velocity, pressure, and temperature fields for both materials, and identified low-shear recirculation at elbows and downstream tees as zones of elevated particle residence. Lagrangian particle tracking (0.05 μm, no-sticking) showed rapid breakthrough and complete flushing within 13 min, providing a hydraulic susceptibility map for transient retention. After eight months of operation, 17 sections were inspected endoscopically and leached at 60 °C. CPVC exhibited yellow–brown discoloration and highly heterogeneous total organic carbon (TOC) release with hot spots of 16–18 mg·L−1, whereas PVDF showed low, spatially uniform TOC (0.4–2.3 mg·L−1) and minimal fouling; inorganic ions remained at sub-mg·L−1 levels for both materials. Overall, geometry governs where contamination can accumulate, while material properties control its magnitude and persistence, with PVDF providing greater resistance to long-term organic contamination than CPVC.
- Open Access
Application of Membrane Capacitive Deionization as Pretreatment Strategy for Enhancing Salinity Gradient Power Generation
Salinity gradient power (SGP) technologies, including pressure-retarded osmosis (PRO) and reverse electrodialysis (RED), have the potential to be utilized for the purpose of harvesting energy from the difference in salinity between two water streams. One challenge associated with SGP is a reduction in power density due to membrane fouling when impaired water is utilized as a low-salinity water stream. Accordingly, this study sought to explore the feasibility of membrane capacitive deionization (MCDI), a low-energy water treatment technique, as a novel pretreatment method for SGP. Laboratory-scale experiments were conducted to evaluate the impact of MCDI pretreatment on the performance of PRO and RED. The low-salinity water was obtained from a brackish water reverse osmosis (BWRO) plant, while the high-salinity water was a synthetic seawater desalination brine. The removal efficiency of organic and inorganic substances in brackish water reverse osmosis (BWRO) brine by MCDI was estimated, as well as theoretical energy consumption. The results demonstrated that MCDI attained removal efficiencies of up to 88.8% for organic substances and 78.8% for inorganic substances. This resulted in a notable enhancement in the lower density for both PRO and RED. The power density of PRO exhibited a notable enhancement, reaching 3.57 W/m2 in comparison to 1.14 W/m2 recorded for the BWRO brine. Conversely, the power density of RED increased from 1.47 W/m2 to 2.05 W/m2. Given that the energy consumption by MCDI is relatively low, it can be surmised that the MCDI pretreatment enhances the overall efficiency of both PRO and RED. However, to fully capitalize on the benefits of MCDI pretreatment, it is recommended that further process optimization be conducted.
Open AccessApplication of Membrane Capacitive Deionization as Pretreatment Strategy for Enhancing Salinity Gradient Power Generation
Salinity gradient power (SGP) technologies, including pressure-retarded osmosis (PRO) and reverse electrodialysis (RED), have the potential to be utilized for the purpose of harvesting energy from the difference in salinity between two water streams. One challenge associated with SGP is a reduction in power density due to membrane fouling when impaired water is utilized as a low-salinity water stream. Accordingly, this study sought to explore the feasibility of membrane capacitive deionization (MCDI), a low-energy water treatment technique, as a novel pretreatment method for SGP. Laboratory-scale experiments were conducted to evaluate the impact of MCDI pretreatment on the performance of PRO and RED. The low-salinity water was obtained from a brackish water reverse osmosis (BWRO) plant, while the high-salinity water was a synthetic seawater desalination brine. The removal efficiency of organic and inorganic substances in brackish water reverse osmosis (BWRO) brine by MCDI was estimated, as well as theoretical energy consumption. The results demonstrated that MCDI attained removal efficiencies of up to 88.8% for organic substances and 78.8% for inorganic substances. This resulted in a notable enhancement in the lower density for both PRO and RED. The power density of PRO exhibited a notable enhancement, reaching 3.57 W/m2 in comparison to 1.14 W/m2 recorded for the BWRO brine. Conversely, the power density of RED increased from 1.47 W/m2 to 2.05 W/m2. Given that the energy consumption by MCDI is relatively low, it can be surmised that the MCDI pretreatment enhances the overall efficiency of both PRO and RED. However, to fully capitalize on the benefits of MCDI pretreatment, it is recommended that further process optimization be conducted.