EBEdward Barrett

Edward Barrett

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Edward Barrett has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Bidirectional Scattering Distribution Function (BSDF) Resolutions for Solar Shading Devices

    by Mandana Sarey Khanie, Mikkel Kofod Pedersen, Frederik Rasmussen, Edward Michael Barrett, David Geisler-Moroder

    This paper investigates the influence of bidirectional scattering distribution function (BSDF) resolution on daylight simulations. Seven representative shading systems were selected and evaluated using a single-office model defined according to established recommendations. The tool genBSDF was used to generate BSDFs at different resolutions. Both annual climate-based and point-in-time daylight simulations were performed. The results show that BSDF resolution has only a minor impact on annual daylight metrics when compared with TT6, used here as the highest-resolution numerical reference, with maximum NRMSE values relative to TT6 of 0.04 for DA300, 0.01 for cDA300, and 0.02 for UDI100–3000 across the investigated systems. Lower-resolution BSDFs (e.g., TT3, TT4, or Klems) are therefore adequate for annual illuminance-based assessments under the conditions studied. In contrast, point-in-time simulations were substantially more sensitive to resolution when direct sunlight penetrated the shading system; for example, NRMSE for one investigated system decreased from 0.63 with TT3 and 0.25 with TT4 to 0.11 with TT5. Lower resolutions also showed greater deviations in the spatial distribution of illuminance, particularly at the transition between directly sunlit and shaded regions. TT5 generally showed close agreement with TT6 while requiring substantially less BSDF-generation time. The findings therefore support selecting BSDF resolution according to simulation purpose: lower resolutions can be used efficiently for annual daylight metrics, whereas higher resolutions, such as TT5 or TT6, are recommended for detailed point-in-time assessments involving strong directional or direct-solar transmission. These findings therefore describe the sensitivity of daylight simulation outcomes to BSDF resolution and their convergence towards TT6, used as the highest-resolution numerical reference, rather than the absolute accuracy of the simulations.

  • Open Access

    Personalized Environmental Control Systems for lighting and daylighting: a systematic review

    by Mandana Sarey Khanie, Alessandra Luna-Navarro, Pedro de la Barra, Pablo Martinez-Alcaraz, Edward Barrett, Douaa Al Assaad, Giorgia Chinazzo, Zhipeng Deng, Bing Dong, Natalia Giraldo Vasquez, et al.

    Personalized Environmental Control Systems (PECS) are increasingly central to user-centered, data-driven buildings. They enable occupants to adjust indoor environmental conditions locally—without affecting others—while reducing unnecessary energy use. Although IEA EBC Annex 87 has defined PECS broadly across indoor domains, its application to the visual environment remains underdeveloped. In lighting and daylighting, PECS include individually controllable task luminaires, dimmable or spectrally tunable workstation lighting, and locally addressable shading or façade systems that modulate daylight and view.This paper extends and operationalizes the Annex 87 definition for the visual domain, explicitly addressing electric lighting and daylight-responsive systems that enable personalized luminous environments. Based on this framework, a systematic review of 46 peer-reviewed studies examines system configurations, evaluation methods, reported benefits, and evidence gaps.More than two-thirds of studies report positive occupant-related outcomes compared to non-personalized conditions, with few non-significant findings. Benefits most commonly include improved visual comfort and satisfaction, reduced override behavior, and increased perceived control. Reported energy savings are consistent: typically 10–40% in simulations and 10–50% in laboratory or field studies, particularly for office-based electric-lighting systems. In contrast, personalized façade and daylighting systems remain underexplored and methodologically diverse.Overall, evidence is strongest for electric-lighting PECS in office settings, while integrated lighting and daylight personalization shows moderate technology readiness. To enhance methodological consistency, this review proposes a minimum reporting checklist addressing control design, user interaction, context, participant characteristics, and visual and non-visual outcomes, supporting broader adoption of adaptive, health-oriented, low-carbon lighting strategies.

  • Open Access

    Effects of Spectral Composition and Illuminance on Walking Performance and Prefrontal Cortex Activity in Younger and Older Adults

    by Navaz Davoodian, Chia May Teh, Victoria Sauter, Edward Barrett, Antonia F de C Hamilton

    Lighting affects not only visual performance but also cognitive engagement and mobility, particularly in older adults navigating complex pedestrian environments. However, evidence linking lighting spectrum and intensity to real-world walking behaviour and the underlying cognitive mechanisms remains limited. This study examined how illuminance (5 vs. 500 lux), spectrally distinct lighting conditions (2700 K vs. 6000 K), and environmental complexity (obstacle presence) influence walking performance, prefrontal cortical activity, and subjective experience in younger and older adults under mesopic lighting conditions.Thirty-eight participants completed structured walking tasks in a full-scale pedestrian laboratory under systematically varied lighting conditions. Walking duration was used as a functional indicator of mobility performance. Functional near-infrared spectroscopy (fNIRS) was employed to index prefrontal cortical activation as a marker of cognitive engagement during walking, and participants provided repeated subjective ratings of visual comfort and perceived physical and mental effort following each condition.Results showed that dim and warmer lighting reliably slowed walking, whereas blue-enriched lighting and higher illuminance supported faster walking across environments. Older adults walked more slowly overall but derived greater benefit from blue-enriched lighting in visually and cognitively demanding settings, particularly under dim conditions. Neurophysiological findings revealed selective modulation of prefrontal engagement by lighting and environmental complexity, consistent with changes in attentional support rather than global increases in cognitive load. Subjective ratings indicated higher perceived effort under dim lighting, without reductions in comfort under blue-enriched light.These findings inform evidence-based pedestrian lighting design by showing that blue-enriched light can support safe, comfortable mobility in ageing populations environments.

  • EXPLORING THE ROLE OF THE FALL OF DARKNESS ON LONDON'S THEFT AND ROBBERY INCIDENTS BETWEEN 2013 - 2019

    by Ezgi Erturk, Constantin-Cosmin Ticleanu, Edward Barrett, Peter Raynham, Jemima Unwin Teji

    This study investigates criminal behaviour in London after dark by using Metropolitan Police Services (MPS) crime records from 2013 to 2019 and calculating solar altitude at the time the crime took place. The data was filtered to identify crimes where the time was known to have taken place in a window of 5 minutes or less, and only these were analysed in the study. “Darkness” is defined in this study as the condition when the solar altitude is less than –6 degrees. Findings indicate that robbery and theft from the person increased significantly after dark (p0.0001). The percentage of theft that takes place after dark, increases in Central London, compared to the whole of London. Further analysis found that robbery and theft occurrences have a significant correlation with darkness.

  • Open Access

    Improved intensive care lighting and staff wellbeing: A pilot feasibility service evaluation

    by Sampath Weerakkody, Jemima Unwin Teji, Edward Barrett, Margarita Kousteni, Lorna Flores-Villa, Emma Jenkins, Hugh Montgomery

    Background: The lighting environment in intensive care units (ICUs) is markedly different from natural light, potentially disrupting patients’ circadian rhythms and impacting staff wellbeing. New lighting technologies may mitigate these effects. Methods: A mixed methods service evaluation was conducted in a London ICU using Dyson Lightcycle™ luminaires (DLs) to evaluate staff wellbeing. Wellbeing assessments and user perceptions of the built environment were conducted using validated questionnaires before, during, and after DL deployment. Existing ambient light usage was measured using HOBO devices installed on the ceiling. Additionally, data on DL usage (including spectral data) were collected continuously using Raspberry Pi™ sensors. Results: DL usage was high (>70% per 24 h), primarily as supplementary lighting. Users found DLs easy to control and beneficial for clinical and administrative tasks. Participants assigned a 12.5% higher satisfaction score rated from 0 to 8 of lighting overall during deployment compared to pre-deployment (6.06 ± 0.29 and 5.06 ± 0.60, respectively; p = 0.20). Control variables for the built environment (noise, temperature and air quality) remained unchanged. Staff reported improvements in mood (38%, p < 0.001), fatigue (17.7%, p < 0.001), and sleep quality (21.2%, p = 0.01) during DL use. Discussion: In the first pilot feasibility service evaluation of its kind, the relationship between ICU lighting quality and staff wellbeing was investigated using DLs. We show that it is feasible to equip an ICU with a novel mode of lighting to evaluate both illuminance and user-centred outcomes. The study suggests a positive association between DL use and staff wellbeing, with notable improvements in mood, fatigue and sleep quality. The nature of the emitted light may enhance the space rather than simply illuminate, thus further adding to a feeling of wellbeing. These findings support data from studies which report effects of light brightness and colour on mood. Additionally, there appears to be a signal towards benefit to the user when additional lighting is provided, compared to the current overhead fluorescent luminaires prevalent in most ICUs. In this service evaluation these benefits were demonstrated in ICU staff operating the device. However, it is conceivable that effects such as improved mood and reduced sleep disturbance may have patient benefits too. Conclusion: Local lighting systems like DLs show promise in enhancing ICU staff wellbeing. Their impact on patient outcomes and the potential for broader implementation deserve further investigation in appropriately designed and powered larger-scale trials.


  • Open Access

    Building Performance Evaluation of a New Hospital Building in the UK: Balancing Indoor Environmental Quality and Energy Performance

    by Nishesh Jain, Esfand Burman, Samuel Stamp, Clive Shrubsole, Roderic Bunn, Tin Oberman, Edward Barrett, Francesco Aletta, Jian Kang, Peter Raynham, et al.

    Hospitals are controlled yet complex ecosystems which provide a therapeutic environment that promotes healing, wellbeing and work efficiency for patients and staff. As these buildings accommodate the sick and vulnerable, occupant wellbeing and good indoor environmental quality (IEQ) that deals with indoor air quality (IAQ), thermal comfort, lighting and acoustics are important objectives. As the specialist nature of hospital function demands highly controlled indoor environments, this makes them energy intensive buildings due to the complex and varying specifications for their functions and operations. This paper reports on a holistic building performance evaluation covering aspects of indoor air quality, thermal comfort, lighting, acoustics, and energy use. It assesses the performance issues and inter-relationships between IEQ and energy in a new building on a hospital campus in the city of Bristol, United Kingdom. The empirical evidence collated from this case study and the feedback received from the hospital staff help identify the endemic issues and constraints related to hospital buildings, such as the need for robust ventilation strategies in hospitals in urban areas that mitigate the effect of indoor and outdoor air pollution and ensuring the use of planned new low-carbon technologies. Whilst the existing guidelines for building design provide useful instructions for the protection of hospital buildings against ingress of particulate matter from outdoors, more advanced filtration strategies may be required to enact chemical reactions required to control the concentration levels of pollutants such as nitrogen dioxide and benzene. Further lessons for improved performance in operation and maintenance of hospitals are highlighted. These include ensuring that the increasingly available metering and monitoring data in new buildings, through building management systems, is used for efficient and optimal building operations for better IEQ and energy management. Overall, the study highlights the need for an integrated and holistic approach to building performance to ensure that healthy environments are provided while energy efficiency targets are met.


  • Transient Photoresponse of Organic Photodetectors

    by Edward M. Barrett, Xuhua Wang, Paul N. Stavrinou, Donal D. C. Bradley

    Organic photodetectors made from regioregular poly(3-hexylthiophene) [P3HT] and [6,6]-phenyl C61 butyric-acid methyl-ester [PCBM] with a broad internal quantum efficiency spectrum reaching 45% at 510 nm have been shown to have a bandwidth of 500Khz that changes with device geometry.