Giovanni Grillo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Giovanni Grillo has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre Coelho
Servicio de Cirugía Ortopédica y Traumatología, Hospital del Mar, Universitat Autònoma de Barcelona, Barcelona, España
1 shared publication - Christian Yela-Verdú
Department of Orthopedics and Traumatology, Knee Unit, Parc Taulí Hospital Universitari, Institut d'Investigació I Innovació Parc Taulí (I3PT‐CERCA) Universitat Autònoma Barcelona (UAB) Sabadell Spain
1 shared publication - David Martí
Knee Unit, Department of Orthopaedics and Traumatology, Parc Taulí Hospital Universitari, Institut d’Investigació I Innovació Parc Taulí (I3PT-CERCA), Universitat Autònoma Barcelona (UAB), 08208 Sabadell, Spain
1 shared publication - Ferran Fillat-Gomà
Consorcio Corporacion Sanitaria Parc Tauli
1 shared publication - Juan Manuel Peñalver Matamoros
Knee Unit, Department of Orthopaedics and Traumatology, Parc Taulí Hospital Universitari, Institut d’Investigació I Innovació Parc Taulí (I3PT-CERCA), Universitat Autònoma Barcelona (UAB), 08208 Sabadell, Spain
1 shared publication - Marçal Pineda Tortajada
Medicine and Surgery Faculty, Universitat Autonoma de Barcelona, 08193 Bellaterra, Spain
1 shared publication
Latest Publications
- Open Access
- 14 October 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (20) , 7926
Mediolateral Joint Balance Assessment Is Reproducible Between Surgeons, Under No Standardized Varus–Valgus Stress, During Robot-Assisted Total Knee Arthroplasty
Objective: To evaluate inter-surgeon variability in mediolateral joint balance assessment during robotic-assisted total knee arthroplasty (TKA) using the robotic surgical assistant (ROSA) Knee System, and to determine whether such variability influences the surgical planning generated by this system. Methods: An observational study was conducted including 101 patients undergoing primary robotic-assisted TKA. Two experienced surgeons independently assessed intraoperative mediolateral laxity by manually applying varus–valgus stress across six predefined flexion angles (0°, 30°, 45°, 60°, 90°, and 120°). Measurements of medial and lateral gaps (mm) and varus–valgus alignment (°) were recorded using the ROSA Knee System. Inter-observer differences were analysed using the Wilcoxon signed-rank test, and reliability was assessed using the intraclass correlation coefficient (ICC). The impact of inter-surgeon variability on surgical planning, including bone resection and compartmental space measurement parameters, was also evaluated. Results: No statistically significant inter-observer differences were observed in mediolateral gap measurements or varus–valgus alignment across all flexion angles (p > 0.05). Inter-observer reliability for varus–valgus measurements was good to excellent in extension and early flexion (ICC 0.86–0.91), decreased to moderate at 90° (ICC 0.68–0.74) and was poor for varus assessment at 120° (ICC 0.46, 95% CI 0.29–0.60). For gap measurements, reliability was excellent for the medial gap and good for the lateral gap in extension (ICC 0.93 and 0.89, respectively), and moderate for both gaps at 90° (ICC 0.71–0.74). No significant inter-observer differences were found in cut or space measurements, with excellent agreement for cut parameters (ICC > 0.95). Conclusions: Inter-surgeon assessment of mediolateral joint balance during robot-assisted TKA showed good-to-excellent reproducibility in extension and early flexion, with reduced reproducibility in deep flexion. Statistically significant inter-observer differences were not observed in the resulting cut and space measurements.
- 14 October 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (20) , 7926
Open AccessMediolateral Joint Balance Assessment Is Reproducible Between Surgeons, Under No Standardized Varus–Valgus Stress, During Robot-Assisted Total Knee Arthroplasty
Objective: To evaluate inter-surgeon variability in mediolateral joint balance assessment during robotic-assisted total knee arthroplasty (TKA) using the robotic surgical assistant (ROSA) Knee System, and to determine whether such variability influences the surgical planning generated by this system. Methods: An observational study was conducted including 101 patients undergoing primary robotic-assisted TKA. Two experienced surgeons independently assessed intraoperative mediolateral laxity by manually applying varus–valgus stress across six predefined flexion angles (0°, 30°, 45°, 60°, 90°, and 120°). Measurements of medial and lateral gaps (mm) and varus–valgus alignment (°) were recorded using the ROSA Knee System. Inter-observer differences were analysed using the Wilcoxon signed-rank test, and reliability was assessed using the intraclass correlation coefficient (ICC). The impact of inter-surgeon variability on surgical planning, including bone resection and compartmental space measurement parameters, was also evaluated. Results: No statistically significant inter-observer differences were observed in mediolateral gap measurements or varus–valgus alignment across all flexion angles (p > 0.05). Inter-observer reliability for varus–valgus measurements was good to excellent in extension and early flexion (ICC 0.86–0.91), decreased to moderate at 90° (ICC 0.68–0.74) and was poor for varus assessment at 120° (ICC 0.46, 95% CI 0.29–0.60). For gap measurements, reliability was excellent for the medial gap and good for the lateral gap in extension (ICC 0.93 and 0.89, respectively), and moderate for both gaps at 90° (ICC 0.71–0.74). No significant inter-observer differences were found in cut or space measurements, with excellent agreement for cut parameters (ICC > 0.95). Conclusions: Inter-surgeon assessment of mediolateral joint balance during robot-assisted TKA showed good-to-excellent reproducibility in extension and early flexion, with reduced reproducibility in deep flexion. Statistically significant inter-observer differences were not observed in the resulting cut and space measurements.
- Open Access
- 1 January 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (1) , e70159
3D printing technology is a more accurate tool than an experienced surgeon in performing femoral bone tunnels in multi‐ligament knee injuries
Purpose: Current surgical methods for multi‐ligament knee reconstruction involve the creation of several reconstruction tunnels in the distal femur. However, the limited bone mass in the knee increases the risk of tunnel convergence. Increasing the accuracy of tunnel direction can minimize tunnel collision during anatomical reconstruction. 3D‐printed patient‐specific instrumentation (PSI) has gained prominence in orthopaedic surgery due to its precision. This study aims to compare the accuracy of PSI with that of the ‘freehand’ approach by an experienced surgeon for drilling the medial and lateral femoral tunnels while adhering to the recommended angulations for multi‐ligament knee injuries.Methods: Ten cadaveric knees underwent computerized tomography (CT) scans to identify anatomical femoral attachments of the lateral collateral ligament (LCL), popliteal tendon (PT), medial collateral ligament (MCL) and posterior oblique ligament (POL). Using Materialise Mimics Medical v25.0 software, virtual planning of a bone tunnel for each ligament was performed, and a total of four tunnels per knee were obtained. Ten PSIs were designed for five knees: five for the medial side and five for the lateral side. The first five knees were operated on via PSI, and the other five knees were operated on by an experienced surgeon using freehand drilling based on preoperative plans. The angular deviation and entry point were assessed by overlaying post‐operative CT images onto preoperative CT images.Results: In the freehand group, the median angular deviation was 22.3°, with an interquartile range (IQR) of 17.6–25.2°. The PSI group presented a significantly greater accuracy in angular deviation for femoral tunnels of 5.7°, with an IQR of 4–8.2° (p < 0.001). Compared with that in the preoperative planning group, the median entry point distance in the freehand group was 5.5 mm, with an IQR of 2.6–8.8 mm. The PSI group had a median entry point distance of 4.2 mm, with an IQR of 3.6–5.7 mm (p = n.s).Conclusions: Compared with the freehand technique performed by an experienced surgeon, PSI demonstrated significantly greater accuracy in terms of the mean angular deviation.Level of Evidence: Level V.
- 1 January 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (1) , e70159
Open Access3D printing technology is a more accurate tool than an experienced surgeon in performing femoral bone tunnels in multi‐ligament knee injuries
Purpose: Current surgical methods for multi‐ligament knee reconstruction involve the creation of several reconstruction tunnels in the distal femur. However, the limited bone mass in the knee increases the risk of tunnel convergence. Increasing the accuracy of tunnel direction can minimize tunnel collision during anatomical reconstruction. 3D‐printed patient‐specific instrumentation (PSI) has gained prominence in orthopaedic surgery due to its precision. This study aims to compare the accuracy of PSI with that of the ‘freehand’ approach by an experienced surgeon for drilling the medial and lateral femoral tunnels while adhering to the recommended angulations for multi‐ligament knee injuries.Methods: Ten cadaveric knees underwent computerized tomography (CT) scans to identify anatomical femoral attachments of the lateral collateral ligament (LCL), popliteal tendon (PT), medial collateral ligament (MCL) and posterior oblique ligament (POL). Using Materialise Mimics Medical v25.0 software, virtual planning of a bone tunnel for each ligament was performed, and a total of four tunnels per knee were obtained. Ten PSIs were designed for five knees: five for the medial side and five for the lateral side. The first five knees were operated on via PSI, and the other five knees were operated on by an experienced surgeon using freehand drilling based on preoperative plans. The angular deviation and entry point were assessed by overlaying post‐operative CT images onto preoperative CT images.Results: In the freehand group, the median angular deviation was 22.3°, with an interquartile range (IQR) of 17.6–25.2°. The PSI group presented a significantly greater accuracy in angular deviation for femoral tunnels of 5.7°, with an IQR of 4–8.2° (p < 0.001). Compared with that in the preoperative planning group, the median entry point distance in the freehand group was 5.5 mm, with an IQR of 2.6–8.8 mm. The PSI group had a median entry point distance of 4.2 mm, with an IQR of 3.6–5.7 mm (p = n.s).Conclusions: Compared with the freehand technique performed by an experienced surgeon, PSI demonstrated significantly greater accuracy in terms of the mean angular deviation.Level of Evidence: Level V.