Wondwossen Lerebo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wondwossen Lerebo has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Hansel Javier Otero
Radiology Department, Children’s Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA 19146, USA
2 shared publications - Ami Gokli
Department of Radiology, Staten Island University Hospital, Staten Island, USA
1 shared publication - Ammie M. White
Department of Radiology, Childrens Hospital of Philadelphia, Philadelphia, USA
1 shared publication - Angel J. Velazquez Guzman
Department of Radiology, Childrens Hospital of Philadelphia, Philadelphia, USA
1 shared publication - Ankita Chauhan
Department of Radiology, Childrens Hospital of Philadelphia, Philadelphia, USA
1 shared publication - Anush Sridharan
Children’s Hospital of Philadelphia, Philadelphia, USA
1 shared publication
Latest Publications
- Open Access
- 26 September 2026
- Published by Springer Nature in Pediatric Radiology
- p. 1-9
Distal humeral physeal separation: radiographic findings in infants and toddlers
Background: Distal humeral physeal separation is an uncommon but frequently misdiagnosed injury of the immature elbow in infants and toddlers that carries a strong association with non-accidental trauma; its largely unossified anatomy makes radiographic diagnosis challenging. Objective: To evaluate radiographic features that can aid in the diagnosis of distal humeral physeal separation among infants and toddlers. Materials and methods: This retrospective comparative study included 19 children under 3 years of age with clinically or surgically confirmed distal humeral physeal separation and available pretreatment elbow and forearm radiographs, identified from the imaging database of a tertiary-care children’s hospital (January 2008 to December 2024). Thirty-two age- and sex-matched control children without elbow fracture were selected from the same source population. Two radiologists independently reviewed all examinations, blinded to fracture status, and recorded the presence or absence of soft tissue swelling, joint effusion, abnormal ossific fragmentation, and abnormal medial or posterior forearm alignment. Findings were compared between children with and without separation injury. Results: This study group included 51 children (32 boys, 19 girls; median age, 17 days, range, 0–1186 days). Soft-tissue swelling (anteroposterior: 94.7% vs 34.4%, P <.001; lateral: 78.9% vs 12.5%, P <.001), abnormal ossific fragmentation (78.9% vs 3.1%, P <.001), and abnormal forearm alignment (medial: 89.5% vs 0%, P <.001; posterior: 78.6% vs 0%, P <.001) were more common in children with physeal separation than those without. On multivariable analysis, abnormal medial forearm alignment remained associated with physeal separation (OR=104.2; 95% CI, 3.9–2775.5; P =.001). Conclusion: In our study group, several radiographic findings were associated with distal humeral physeal separation in infants and toddlers; however, only abnormal medial forearm alignment remained strongly associated with physeal separation.
- 26 September 2026
- Published by Springer Nature in Pediatric Radiology
- p. 1-9
Open AccessDistal humeral physeal separation: radiographic findings in infants and toddlers
Background: Distal humeral physeal separation is an uncommon but frequently misdiagnosed injury of the immature elbow in infants and toddlers that carries a strong association with non-accidental trauma; its largely unossified anatomy makes radiographic diagnosis challenging. Objective: To evaluate radiographic features that can aid in the diagnosis of distal humeral physeal separation among infants and toddlers. Materials and methods: This retrospective comparative study included 19 children under 3 years of age with clinically or surgically confirmed distal humeral physeal separation and available pretreatment elbow and forearm radiographs, identified from the imaging database of a tertiary-care children’s hospital (January 2008 to December 2024). Thirty-two age- and sex-matched control children without elbow fracture were selected from the same source population. Two radiologists independently reviewed all examinations, blinded to fracture status, and recorded the presence or absence of soft tissue swelling, joint effusion, abnormal ossific fragmentation, and abnormal medial or posterior forearm alignment. Findings were compared between children with and without separation injury. Results: This study group included 51 children (32 boys, 19 girls; median age, 17 days, range, 0–1186 days). Soft-tissue swelling (anteroposterior: 94.7% vs 34.4%, P <.001; lateral: 78.9% vs 12.5%, P <.001), abnormal ossific fragmentation (78.9% vs 3.1%, P <.001), and abnormal forearm alignment (medial: 89.5% vs 0%, P <.001; posterior: 78.6% vs 0%, P <.001) were more common in children with physeal separation than those without. On multivariable analysis, abnormal medial forearm alignment remained associated with physeal separation (OR=104.2; 95% CI, 3.9–2775.5; P =.001). Conclusion: In our study group, several radiographic findings were associated with distal humeral physeal separation in infants and toddlers; however, only abnormal medial forearm alignment remained strongly associated with physeal separation.
- Open Access
- 7 February 2026
- Published by Springer Nature in Pediatric Radiology
- Vol. 56 (3) , 629-637
How we do it: artery of Adamkiewicz evaluation by CTA in children
Identifying the artery of Adamkiewicz (AoA) is essential for minimizing the risk of spinal cord ischemia that can result from injury or displacement during aortopexy. A pre-operative CT angiogram (CTA) is commonly requested; however, locating the artery can be challenging due to its small size and variable course. To enhance the visualization of the artery of Adamkiewicz, it is effective to increase the tube current while maintaining a low kV of 70 and raising the Hounsfield unit (HU) trigger threshold. This method adheres to the As Low As Reasonably Achievable (ALARA) principle, ensuring a reliably diagnostic study.
- 7 February 2026
- Published by Springer Nature in Pediatric Radiology
- Vol. 56 (3) , 629-637
Open AccessHow we do it: artery of Adamkiewicz evaluation by CTA in children
Identifying the artery of Adamkiewicz (AoA) is essential for minimizing the risk of spinal cord ischemia that can result from injury or displacement during aortopexy. A pre-operative CT angiogram (CTA) is commonly requested; however, locating the artery can be challenging due to its small size and variable course. To enhance the visualization of the artery of Adamkiewicz, it is effective to increase the tube current while maintaining a low kV of 70 and raising the Hounsfield unit (HU) trigger threshold. This method adheres to the As Low As Reasonably Achievable (ALARA) principle, ensuring a reliably diagnostic study.
- 18 December 2024
- Published by Springer Nature in Pediatric Radiology
- Vol. 55 (2) , 297-304
3D ultrasound volume quantification for pediatric urinary tract dilation: a semi-automated segmentation software inter-rater analysis
Objective We determined the reliability of a three-dimensional (3D) ultrasound (US) segmentation software for evaluating volumetric hydronephrosis index (HI) and renal parenchymal and pelvicalyceal volume in children with urinary tract dilation (UTD). Material and methods From 1/2019 to 9/2023, children clinically scheduled for a renal imaging exam to assess UTD at a single center were prospectively enrolled. They underwent a dedicated two-dimensional (2D) and 3D US renal exam. A UTD score was assigned per kidney from the 2D images based on the 2014 consensus classification by an experienced pediatric radiologist. From the 3D dataset, the renal parenchyma and collecting system were independently segmented by three trained raters using a semi-automated software. From this segmentation, the kidney parenchymal and pelvicalyceal volume, dimensions, and volumetric HI values were analyzed using the intraclass correlation coefficient to grade inter-rater reliability. Results Forty-eight studies from 47 patients were included (65% male; median age 24 months; IQR 61 months). From these, 46 right and 40 left kidneys were chosen based on image quality. Twenty-nine (33.7%) kidneys had no UTD, 10 (11.6%) had UTD P1, 23 (26.7%) had UTD P2, and 24 (27.9%) had UTD P3. Inter-rater reliability was almost perfect across all parameters, with estimates ranging from 0.85 to 0.95. In sub-analysis of kidneys with UTD P2 and UTD P3, volumetric HI had the lowest inter-rater agreement (0.75 and 0.66, respectively). Conclusions Semi-automated 3D US segmentation for kidneys with UTD can reliably assess renal dimensions, parenchymal and collecting system volumes, and volumetric HI among raters. Graphical Abstract
- 18 December 2024
- Published by Springer Nature in Pediatric Radiology
- Vol. 55 (2) , 297-304
3D ultrasound volume quantification for pediatric urinary tract dilation: a semi-automated segmentation software inter-rater analysis
Objective We determined the reliability of a three-dimensional (3D) ultrasound (US) segmentation software for evaluating volumetric hydronephrosis index (HI) and renal parenchymal and pelvicalyceal volume in children with urinary tract dilation (UTD). Material and methods From 1/2019 to 9/2023, children clinically scheduled for a renal imaging exam to assess UTD at a single center were prospectively enrolled. They underwent a dedicated two-dimensional (2D) and 3D US renal exam. A UTD score was assigned per kidney from the 2D images based on the 2014 consensus classification by an experienced pediatric radiologist. From the 3D dataset, the renal parenchyma and collecting system were independently segmented by three trained raters using a semi-automated software. From this segmentation, the kidney parenchymal and pelvicalyceal volume, dimensions, and volumetric HI values were analyzed using the intraclass correlation coefficient to grade inter-rater reliability. Results Forty-eight studies from 47 patients were included (65% male; median age 24 months; IQR 61 months). From these, 46 right and 40 left kidneys were chosen based on image quality. Twenty-nine (33.7%) kidneys had no UTD, 10 (11.6%) had UTD P1, 23 (26.7%) had UTD P2, and 24 (27.9%) had UTD P3. Inter-rater reliability was almost perfect across all parameters, with estimates ranging from 0.85 to 0.95. In sub-analysis of kidneys with UTD P2 and UTD P3, volumetric HI had the lowest inter-rater agreement (0.75 and 0.66, respectively). Conclusions Semi-automated 3D US segmentation for kidneys with UTD can reliably assess renal dimensions, parenchymal and collecting system volumes, and volumetric HI among raters. Graphical Abstract
- 7 December 2024
- Published by Springer Nature in Pediatric Radiology
- Vol. 55 (2) , 259-267
RADHawk—an AI-based knowledge recommender to support precision education, improve reporting productivity, and reduce cognitive load
Background Using artificial intelligence (AI) to augment knowledge is key to establishing precision education in modern radiology training. Our department has developed a novel AI-derived knowledge recommender, the first reported precision education program in radiology, RADHawk (RH), that augments the training of radiology residents and fellows by pushing personalized and relevant educational content in real-time and in context with the case being interpreted. Purpose To assess the impact on trainees of an AI-based knowledge recommender compared to traditional knowledge sourcing for radiology reporting through reporting time, quality, cognitive load, and learning experiences. Materials and methods A mixed methods prospective study allocated trainees to intervention and control groups, working with and without access to RH, respectively. Validated questionnaires and observed and graded simulated picture archiving and communication system (PACS)-based reporting at the start and end of a month’s rotation assessed technology acceptance, case report quality, case report time and sourcing time, cognitive load, and attitudes toward modified learning strategies. Non-parametric regression analyses and Mann–Whitney tests were used to compare outcomes between groups, with significance set at Pn=28) demonstrated a statistically significant reduction in the case report time by -162 s per case (95%CI -275.76 s to -52.40 s) (P-value = 0.002) and an increase of 14% (95%CI 8.1–19.8%) (P-value 78% of the intervention group gave positive ratings on RH’s effectiveness, increase in productivity, job usefulness, and ease of use. Eighty-nine percent of participants in the intervention group requested access to RH for their next rotation. Conclusion This study demonstrates that RH, as the first reported AI-derived knowledge recommender for radiology education, significantly reduces reporting time and improves reporting accuracy while reducing overall workload and mental demand for radiology trainees. The high acceptance among trainees suggests its potential for supporting self-directed learning. Further testing of a larger external cohort will support more widespread implementation of RH for precision education. Graphical Abstract
- 7 December 2024
- Published by Springer Nature in Pediatric Radiology
- Vol. 55 (2) , 259-267
RADHawk—an AI-based knowledge recommender to support precision education, improve reporting productivity, and reduce cognitive load
Background Using artificial intelligence (AI) to augment knowledge is key to establishing precision education in modern radiology training. Our department has developed a novel AI-derived knowledge recommender, the first reported precision education program in radiology, RADHawk (RH), that augments the training of radiology residents and fellows by pushing personalized and relevant educational content in real-time and in context with the case being interpreted. Purpose To assess the impact on trainees of an AI-based knowledge recommender compared to traditional knowledge sourcing for radiology reporting through reporting time, quality, cognitive load, and learning experiences. Materials and methods A mixed methods prospective study allocated trainees to intervention and control groups, working with and without access to RH, respectively. Validated questionnaires and observed and graded simulated picture archiving and communication system (PACS)-based reporting at the start and end of a month’s rotation assessed technology acceptance, case report quality, case report time and sourcing time, cognitive load, and attitudes toward modified learning strategies. Non-parametric regression analyses and Mann–Whitney tests were used to compare outcomes between groups, with significance set at Pn=28) demonstrated a statistically significant reduction in the case report time by -162 s per case (95%CI -275.76 s to -52.40 s) (P-value = 0.002) and an increase of 14% (95%CI 8.1–19.8%) (P-value 78% of the intervention group gave positive ratings on RH’s effectiveness, increase in productivity, job usefulness, and ease of use. Eighty-nine percent of participants in the intervention group requested access to RH for their next rotation. Conclusion This study demonstrates that RH, as the first reported AI-derived knowledge recommender for radiology education, significantly reduces reporting time and improves reporting accuracy while reducing overall workload and mental demand for radiology trainees. The high acceptance among trainees suggests its potential for supporting self-directed learning. Further testing of a larger external cohort will support more widespread implementation of RH for precision education. Graphical Abstract