Wenyu Zhang
Wenyu Zhang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Gang Li
Department of Electronic Engineering, Tsinghua University, Beijing, China
2 shared publications - Chunfang Du
Inner Mongolia University
1 shared publication Hao Wu
Beijing Qinglei Technology Co. Ltd. Beijing China
1 shared publication- Li Zheng
Department of Otolaryngology Head and Neck Surgery, Beijing Children's Hospital, Capital Medical University, National Children's Medical Center, Beijing, China
1 shared publication - Ruobing Song
Department of Respiratory, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
1 shared publication - Wei Wang
Tsinghua University
1 shared publication
Latest Publications
- 29 July 2025
- Published by Elsevier in Sleep Health
- Vol. 11 (6) , 859-867
Deep learning-based automated diagnosis of obstructive sleep apnea and sleep stage classification in children using millimeter-wave radar and pulse oximeter
- 29 July 2025
- Published by Elsevier in Sleep Health
- Vol. 11 (6) , 859-867
Deep learning-based automated diagnosis of obstructive sleep apnea and sleep stage classification in children using millimeter-wave radar and pulse oximeter
- 13 April 2022
- Published by Elsevier in Applied Clay Science
- Vol. 224, 106509
Halloysite nanotubes supported copper oxide composites used as efficient catalysts for bisphenol A removal
- 13 April 2022
- Published by Elsevier in Applied Clay Science
- Vol. 224, 106509
Halloysite nanotubes supported copper oxide composites used as efficient catalysts for bisphenol A removal
- Open Access
- 22 November 2021
- Published by Institution of Engineering and Technology (IET) in IET Radar, Sonar & Navigation
- Vol. 16 (3) , 456-469
Non‐contact monitoring of human heartbeat signals using mm‐wave frequency‐modulated continuous‐wave radar under low signal‐to‐noise ratio conditions
Radar has been shown potentially to be used for non‐contact sensing of biosignals in a more comfortable and easier way than wearable and contact devices. By detecting and extracting body motions linked to physiological activities, accurate estimation of the heart rate is possible. However, the detection and estimation of heartbeat signal in practical applications is disturbed seriously by noise and respiration harmonic signal. In this study, a multi‐level coarse‐to‐fine method is proposed for heartbeat rate (HR) estimation with a frequency‐modulated continuous‐wave radar operating at 60 GHz utilised to extract the heartbeat information of human body under low signal‐to‐noise ratio conditions. First, the frequencies, which are likely to be the HR, are extracted in the coarse estimation part. Then, evaluations about the extracted frequencies are conducted in the fine estimation part. Finally, the multiple signal classification algorithm is utilised to separate the HR frequency from the respiration harmonics, which solves the frequency resolution issue caused by the observation window size, and achieves high accuracy estimation of HR. The experiments on measured data demonstrate the effectiveness of the proposed method. Compared with the state of the art, the proposed method has superiority in terms of estimation accuracy of HR.
- 22 November 2021
- Published by Institution of Engineering and Technology (IET) in IET Radar, Sonar & Navigation
- Vol. 16 (3) , 456-469
Open AccessNon‐contact monitoring of human heartbeat signals using mm‐wave frequency‐modulated continuous‐wave radar under low signal‐to‐noise ratio conditions
Radar has been shown potentially to be used for non‐contact sensing of biosignals in a more comfortable and easier way than wearable and contact devices. By detecting and extracting body motions linked to physiological activities, accurate estimation of the heart rate is possible. However, the detection and estimation of heartbeat signal in practical applications is disturbed seriously by noise and respiration harmonic signal. In this study, a multi‐level coarse‐to‐fine method is proposed for heartbeat rate (HR) estimation with a frequency‐modulated continuous‐wave radar operating at 60 GHz utilised to extract the heartbeat information of human body under low signal‐to‐noise ratio conditions. First, the frequencies, which are likely to be the HR, are extracted in the coarse estimation part. Then, evaluations about the extracted frequencies are conducted in the fine estimation part. Finally, the multiple signal classification algorithm is utilised to separate the HR frequency from the respiration harmonics, which solves the frequency resolution issue caused by the observation window size, and achieves high accuracy estimation of HR. The experiments on measured data demonstrate the effectiveness of the proposed method. Compared with the state of the art, the proposed method has superiority in terms of estimation accuracy of HR.