Kuan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kuan Li has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Jinlong Tan
State Grid Xinjiang Electric Power Research Institute, Urumqi 830047, China
1 shared publication - Lu Zhang
Electric Power Research Institute, Xinjiang Electric Power Co., Ltd., Urumqi 830011, China
1 shared publication - Qi Zhao
State Grid Xinjiang Electric Power Research Institute, Urumqi 830047, China
1 shared publication - Shuobo Zhang
State Grid Xinjiang Electric Power Research Institute, Urumqi 830047, China
1 shared publication
Latest Publications
- Open Access
- 11 February 2025
- Published by MDPI AG in Electronics
- Vol. 14 (4) , 694
Pole-to-Pole Fault Current Impact Factors Analysis Based on Equivalent Impedance for Modular Multilevel Converter High-Voltage Direct Current System
The fault current in MMC HVDC systems suffers from a quick rising rate and no zero-cross problems, which makes it hard to cut off and has become the main problem when promoting MMC dc systems. Among the different types of faults, the pole-to-pole fault is the most serious one. Hence, to clarify the discharging mechanism during pole-to-pole faults and determine the influential factors, this paper proposes a simplified modeling method for MMC HVDC fault current impact factors analysis. The proposed method uses the simplified MMC circuit when faults happen, and the frequency domain model is then established for fault current analysis. Considering that the fault period concerned always is less than 10 ms, the high-frequency part impedance characteristics of the established model are carefully studied when device parameters are varied. The smoothing reactor has a significant influence on the high-frequency impedance, while the arm inductance and arm resistance have much less impact on high-frequency impedance. This demonstrates, theoretically, that the pole-to-pole fault current is basically influenced by the smoothing reactor rather than other impact factors. The calculation results based on the model also prove that fault current will change a lot if the smoothing reactor’s parameters are different. The analysis verifies the accuracy of the equivalent model and supplies a theoretical analysis tool for MMC HVDC fault current analysis.
- 11 February 2025
- Published by MDPI AG in Electronics
- Vol. 14 (4) , 694
Open AccessPole-to-Pole Fault Current Impact Factors Analysis Based on Equivalent Impedance for Modular Multilevel Converter High-Voltage Direct Current System
The fault current in MMC HVDC systems suffers from a quick rising rate and no zero-cross problems, which makes it hard to cut off and has become the main problem when promoting MMC dc systems. Among the different types of faults, the pole-to-pole fault is the most serious one. Hence, to clarify the discharging mechanism during pole-to-pole faults and determine the influential factors, this paper proposes a simplified modeling method for MMC HVDC fault current impact factors analysis. The proposed method uses the simplified MMC circuit when faults happen, and the frequency domain model is then established for fault current analysis. Considering that the fault period concerned always is less than 10 ms, the high-frequency part impedance characteristics of the established model are carefully studied when device parameters are varied. The smoothing reactor has a significant influence on the high-frequency impedance, while the arm inductance and arm resistance have much less impact on high-frequency impedance. This demonstrates, theoretically, that the pole-to-pole fault current is basically influenced by the smoothing reactor rather than other impact factors. The calculation results based on the model also prove that fault current will change a lot if the smoothing reactor’s parameters are different. The analysis verifies the accuracy of the equivalent model and supplies a theoretical analysis tool for MMC HVDC fault current analysis.