XGXinyang Ge

Xinyang Ge

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xinyang Ge has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Synchronous wearable ultrasound for early detection of coronary and carotid artery comorbidity

    by Shengrong Lin, Hao Xu, Ya Li, Xinyang Ge, Kang Chen, Lin Chen, Minfeng Tong, Fangyi Wang, Dawei Wu, Hongxiang Lin, et al.

    Coronary heart disease (CHD) and carotid artery disease (CAD) often co-occur. However, conventional diagnosis typically involves separate, site-by-site examinations after symptoms appear, leading to delayed intervention. In this work, we developed a wearable ultrasound system that enables synchronous monitoring of cardiac and carotid dynamics for comorbidity assessment. The system combines dual wearable ultrasound patches, a synchronous imaging strategy, artificial intelligence–based image processing algorithms, and human circuitry models to automatically extract and analyze key cardiac-carotid metrics, such as heart rate, pulse rate, cardiac volume, cardiac output, and carotid blood pressure. By evaluating the correlation of these metrics between modeling and measurements, we showed the feasibility of differentiating among healthy participants and patients with CAD, CHD, or CAD-CHD comorbidity. This integrated approach constitutes a promising framework for supporting the proactive assessment of coronary-carotid comorbidity.


  • Open Access

    Cardiac Structural and Functional Evaluation Using a Heart Motion Correction Algorithm for Coronary Computed Tomography Angiography in Patients With High Heart Rates

    by Xiaorong Chen, Yanping Dong, Aiyun Sun, Hao Xu, Xinyang Ge, Ronghua Wu, Shanshan Ying, Xiu Zhang, Jing Yuan, Jiangfeng Pan

    Background: The heart motion correction algorithm used in current multi-slice computed tomography (CT) is sufficient for coronary artery imaging in patients with high heart rates. However, the effect of this algorithm on the image quality in whole-cardiac-cycle reconstructions remains unclear. Therefore, this study aimed to investigate image quality, segmentation performance, and cardiac structure and function assessment using a heart motion correction algorithm for coronary CT angiography in patients with rapid heart rates. Methods: This study retrospectively collected data from 58 consecutive patients with high heart rates (≥80 beats/min), of whom 36 also underwent cardiac magnetic resonance (CMR) imaging. CT images were reconstructed from 0% to 100% in 5% increments using the standard reconstruction (STD) and second-generation snapshot freeze (SSF2) protocols, and then processed by an automatic heart segmentation algorithm. Image quality, segmentation performance, cardiac volumes, and functional parameters were compared between protocols. Results: Compared with the STD protocol, the SSF2 protocol yielded a higher image quality score (3.91 ± 0.29 vs. 3.84 ± 0.37; p < 0.01), a steeper edge rise slope (41.71 ± 19.03 vs. 25.59 ± 13.16; p < 0.01), and lower entropy (4.12 ± 0.48 vs. 4.40 ± 0.28; p < 0.01). For left ventricular end-diastolic volume, the intraclass correlation coefficient (ICC) between automatic segmentation and manual contouring for the SSF2 protocol was 0.96, and the coefficient of variation was 7.84%. In contrast, the coefficients of variation for left ventricular end-systolic volume were poor (48.24% for STD and 48.18% for SSF2). Differences in global circumferential strain (–13.30 ± 3.42 vs. –15.01 ± 4.44; p < 0.01) and global longitudinal strain (–11.80 ± 4.83 vs. –13.01 ± 4.36; p < 0.01) between SSF2 and CMR were statistically significant, although correlations (ICC = 0.90 and 0.85, respectively) were good. Conclusions: SSF2 significantly improves image quality, structure, and function, and enables strain assessment in whole-cardiac-cycle reconstructions in patients with high heart rates. SSF2 also demonstrates superior performance over the STD protocol for evaluating myocardial strain.

    • 18 May 2026
      • Vol. 27  (5)
    Open Access

    Cardiac Structural and Functional Evaluation Using a Heart Motion Correction Algorithm for Coronary Computed Tomography Angiography in Patients With High Heart Rates

    by Xiaorong Chen, Yanping Dong, Aiyun Sun, Hao Xu, Xinyang Ge, Ronghua Wu, Shanshan Ying, Xiu Zhang, Jing Yuan, Jiangfeng Pan

    The heart motion correction algorithm used in current multi-slice computed tomography (CT) is sufficient for coronary artery imaging in patients with high heart rates. However, the effect of this algorithm on the image quality in whole-cardiac-cycle reconstructions remains unclear. Therefore, this study aimed to investigate image quality, segmentation performance, and cardiac structure and function assessment using a heart motion correction algorithm for coronary CT angiography in patients with rapid heart rates. This study retrospectively collected data from 58 consecutive patients with high heart rates (≥80 beats/min), of whom 36 also underwent cardiac magnetic resonance (CMR) imaging. CT images were reconstructed from 0% to 100% in 5% increments using the standard reconstruction (STD) and second-generation snapshot freeze (SSF2) protocols, and then processed by an automatic heart segmentation algorithm. Image quality, segmentation performance, cardiac volumes, and functional parameters were compared between protocols. Compared with the STD protocol, the SSF2 protocol yielded a higher image quality score (3.91 ± 0.29 vs. 3.84 ± 0.37; p < 0.01), a steeper edge rise slope (41.71 ± 19.03 vs. 25.59 ± 13.16; p < 0.01), and lower entropy (4.12 ± 0.48 vs. 4.40 ± 0.28; p < 0.01). For left ventricular end-diastolic volume, the intraclass correlation coefficient (ICC) between automatic segmentation and manual contouring for the SSF2 protocol was 0.96, and the coefficient of variation was 7.84%. In contrast, the coefficients of variation for left ventricular end-systolic volume were poor (48.24% for STD and 48.18% for SSF2). Differences in global circumferential strain (–13.30 ± 3.42 vs. –15.01 ± 4.44; p < 0.01) and global longitudinal strain (–11.80 ± 4.83 vs. –13.01 ± 4.36; p < 0.01) between SSF2 and CMR were statistically significant, although correlations (ICC = 0.90 and 0.85, respectively) were good. SSF2 significantly improves image quality, structure, and function, and enables strain assessment in whole-cardiac-cycle reconstructions in patients with high heart rates. SSF2 also demonstrates superior performance over the STD protocol for evaluating myocardial strain.

  • Hemodynamic analysis on the umbilical cord with different coiling and nuchal cord conditions: A computational model-based study

    by Tianqi Wang, Keming Tao, Weiping Wang, Xinyang Ge, Qiuyan Pei

    The umbilical cord is a vital pathway for the fetus, which can bring oxygen/nutrition and take away waste products to maintain normal growth. Clinical studies found that abnormal coiling and nuchal cord conditions of the umbilical cord may be associated with fetal growth restriction. Although the hemodynamic environment due to the abnormal morphology is suspected to account for the abnormal growth, the specific influence of the abnormal coiling and nuchal cord conditions on the hemodynamics remains not fully understood. In this context, this study aims to investigate the hemodynamic effects of the variation of umbilical coiling index (UCI) and nuchal cord conditions in order to better address the issue. For this purpose, the computational model of a normal umbilical cord was constructed based on the ultrasound-measured geometrical parameters and blood flow velocity. On this basis, a series of computational models with lower/higher UCI and with/without nuchal cord were then constructed, which were used in the hemodynamic analysis and comparison. Results showed that (1) both abnormal UCI (lower and higher) and nuchal cord conditions significantly altered the hemodynamic environment; (2) the variations of UCI resulted in inverse tendencies between oscillatory shear index (OSI) and relative residence time (RRT); and (3) nuchal cord had minor impact on most hemodynamic variables, such as wall shear stress and RRT, but increased the area of higher OSI. These findings clarified the influence of different coiling and nuchal cord conditions on the hemodynamic environment of the umbilical cord, which would provide more insights into fetal growth restriction.