DFD. J. Fixsen

D. J. Fixsen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


D. J. Fixsen has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Primordial Inflation Explorer (PIXIE): mission design and science goals

    by Alan Kogut, Nabila Aghanim, Jens Chluba, David T. Chuss, Jacques Delabrouille, Cora Dvorkin, Dale Fixsen, Shamik Ghosh, Brandon S. Hensley, J. Colin Hill, et al.

    The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept to measure the energy spectrum and linear polarization of the cosmic microwave background (CMB). A single cryogenic Fourier transform spectrometer compares the sky to an external blackbody calibration target, measuring the Stokes I, Q, U parameters to levels ∼200 Jy/sr in each 2.65° diameter beam over the full sky, in each of 300 frequency channels from 28 GHz to 6 THz. With sensitivity over 1000 times greater than COBE/FIRAS, PIXIE opens a broad discovery space for the origin, contents, and evolution of the universe. Measurements of small distortions from a CMB blackbody spectrum provide a robust determination of the mean electron pressure and temperature in the universe while constraining processes including dissipation of primordial density perturbations, black holes, and the decay or annihilation of dark matter. Full-sky maps of linear polarization measure the optical depth to reionization at nearly the cosmic variance limit and constrain models of primordial inflation. Spectra with sub-percent absolute calibration spanning microwave to far-IR wavelengths provide a legacy data set for analyses including line intensity mapping of extragalactic emission and the cosmic infrared background amplitude and anisotropy. We describe the PIXIE instrument sensitivity, foreground subtraction, and anticipated science return from both the baseline 2-year mission and a potential extended mission.


  • Laboratory results from an ultra-stable MID IR spectrometer for exo-planet atmosphere characterization

    by D. J. Fixsen, J. G. Staguhn, E. Sharp, S. Maher, A. M. Mandell, A. Brown

    We have conducted a set of experiments on a TES (Transition-Edge Superconductor) bolometer detector array, demonstrating that a flux measurement stability better than 5 parts per million (ppm) over periods of hours to days, can be achieved with modest thermal stability requirements. This level of measurement stability is critical in enabling measurements of the atmospheric signatures of terrestrial-sized exoplanets around nearby K and M stars, including those in the star’s habitable zone. The demonstration uses a simple tungsten filament light bulb as the source, a photo diode operating at 0.5 μm as a stability monitor for the light bulb, and a grating spectrometer in the 5–15 μm wavelength range.