Jie Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jie Tang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Baiyang Liu
School of Electrical Engineering, Shaoyang University, Shaoyang, China
1 shared publication- Cheng Deng
School of Electrical Engineering, Shaoyang University, Shaoyang, China
1 shared publication Haineng Yang
School of Electrical Engineering, Shaoyang University, Shaoyang, China
1 shared publicationJintian Yin
School of Electrical Engineering, Shaoyang University, Shaoyang, China
1 shared publicationShuang Li
College of Automation and Electronic Information, Xiangtan University, Xiangtan, China
1 shared publicationWu Shao
School of Electrical Engineering, Shaoyang University, Shaoyang, China
1 shared publication
Latest Publications
- Open Access
- 11 February 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-23
Wind power data cleaning using RANSAC-based polynomial and linear regression with adaptive threshold
As the global demand for clean energy continues to rise, wind power has become one of the most important renewable energy sources. However, wind power data often contains a high proportion of dense anomalies, which not only significantly affect the accuracy of wind power forecasting models but may also mislead grid scheduling decisions, thereby jeopardizing grid security. To address this issue, this paper proposes an adaptive threshold robust regression model (RPR model) based on the combination of the Random Sample Consensus (RANSAC) algorithm and polynomial linear regression for wind power data cleaning. The model successfully captures the nonlinear relationship between wind speed and power by extending the polynomial features of wind speed and power, enabling the linear regression model to handle the nonlinearity. By combining the RANSAC algorithm and polynomial linear regression, a robust polynomial regression model is constructed to tackle anomalous data and enhance the accuracy of data cleaning. During the cleaning process, the model first fits the raw data by randomly selecting a minimal sample set, then dynamically adjusts the decision thresholds based on the median of residuals and median absolute deviation (MAD), ensuring effective identification and cleaning of anomalous data. The model’s robustness allows it to maintain efficient cleaning performance even with a high proportion of anomalous data, addressing the limitations of existing methods when handling densely distributed anomalies. The effectiveness and innovation of the proposed method were validated by applying it to real data from a wind farm operated by Longyuan Power. Compared to other commonly used cleaning methods, such as the Bidirectional Change Point Grouping Quartile Statistical Model, Principal Contour Image Processing Model, DBSCAN Clustering Model, and Support Vector Machine (SVM) Model, experimental results showed that the proposed method delivered the best performance in improving data quality. Specifically, the method significantly reduced the average absolute error (MAE) of the wind power forecasting model by 72.1%, which is higher than the reductions observed in other methods (ranging from 37.3 to 52.7%). Moreover, it effectively reduced the prediction error of the Convolutional Neural Network (CNN) + Gated Recurrent Unit (GRU) forecasting model, ensuring high prediction accuracy. The adaptive threshold robust regression model proposed in this study is innovative and has significant application potential. It provides an effective new approach for wind power data cleaning, applicable not only to conventional scenarios with low proportions of anomalous data but also to complex datasets with a high proportion of dense anomalies.
- 11 February 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-23
Open AccessWind power data cleaning using RANSAC-based polynomial and linear regression with adaptive threshold
As the global demand for clean energy continues to rise, wind power has become one of the most important renewable energy sources. However, wind power data often contains a high proportion of dense anomalies, which not only significantly affect the accuracy of wind power forecasting models but may also mislead grid scheduling decisions, thereby jeopardizing grid security. To address this issue, this paper proposes an adaptive threshold robust regression model (RPR model) based on the combination of the Random Sample Consensus (RANSAC) algorithm and polynomial linear regression for wind power data cleaning. The model successfully captures the nonlinear relationship between wind speed and power by extending the polynomial features of wind speed and power, enabling the linear regression model to handle the nonlinearity. By combining the RANSAC algorithm and polynomial linear regression, a robust polynomial regression model is constructed to tackle anomalous data and enhance the accuracy of data cleaning. During the cleaning process, the model first fits the raw data by randomly selecting a minimal sample set, then dynamically adjusts the decision thresholds based on the median of residuals and median absolute deviation (MAD), ensuring effective identification and cleaning of anomalous data. The model’s robustness allows it to maintain efficient cleaning performance even with a high proportion of anomalous data, addressing the limitations of existing methods when handling densely distributed anomalies. The effectiveness and innovation of the proposed method were validated by applying it to real data from a wind farm operated by Longyuan Power. Compared to other commonly used cleaning methods, such as the Bidirectional Change Point Grouping Quartile Statistical Model, Principal Contour Image Processing Model, DBSCAN Clustering Model, and Support Vector Machine (SVM) Model, experimental results showed that the proposed method delivered the best performance in improving data quality. Specifically, the method significantly reduced the average absolute error (MAE) of the wind power forecasting model by 72.1%, which is higher than the reductions observed in other methods (ranging from 37.3 to 52.7%). Moreover, it effectively reduced the prediction error of the Convolutional Neural Network (CNN) + Gated Recurrent Unit (GRU) forecasting model, ensuring high prediction accuracy. The adaptive threshold robust regression model proposed in this study is innovative and has significant application potential. It provides an effective new approach for wind power data cleaning, applicable not only to conventional scenarios with low proportions of anomalous data but also to complex datasets with a high proportion of dense anomalies.
- 7 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (11) , 13025-13038
A Review of Flexible Multilayer Foil Integration Technology for Passive Components
Passive integration technology is widely used in power electric converters since it can significantly reduce the volume of the passive components and improve the power density. This article highlights the flexible multilayer foil (FMLF) integration technology since it can meet the future requirements than other integration technologies. The realization, structures, and applications of the FMLF integration technology are summarized. The magnetic materials, dielectric materials, and conductive materials used in FMLF are investigated. Then, the approaches of the analysis and design for FMLF integrated units are introduced. Finally, it is compared with the planar printed circuit board integration technology to highlight the advantages of its characteristics and expounds its future research fields. Eventually, the power electronics engineers and researchers can comprehend the intrinsic properties of the FMLF integration technology.
- 7 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (11) , 13025-13038
A Review of Flexible Multilayer Foil Integration Technology for Passive Components
Passive integration technology is widely used in power electric converters since it can significantly reduce the volume of the passive components and improve the power density. This article highlights the flexible multilayer foil (FMLF) integration technology since it can meet the future requirements than other integration technologies. The realization, structures, and applications of the FMLF integration technology are summarized. The magnetic materials, dielectric materials, and conductive materials used in FMLF are investigated. Then, the approaches of the analysis and design for FMLF integrated units are introduced. Finally, it is compared with the planar printed circuit board integration technology to highlight the advantages of its characteristics and expounds its future research fields. Eventually, the power electronics engineers and researchers can comprehend the intrinsic properties of the FMLF integration technology.