Richard Mittleman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Richard Mittleman has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Alan Cumming
University of Glasgow
2 shared publications - Amit Singh Ubhi
University of Birmingham
2 shared publications - Brian Lantz
Stanford University
2 shared publications - D. V. Martynov
University of Birmingham
2 shared publications - Emilia Chick
University of Birmingham
2 shared publications - Giles Hammond
University of Glasgow
2 shared publications
Latest Publications
- Open Access
- 10 June 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (3)
Extending ground-based gravitational-wave sensitivity to 5 Hz
Extending the sensitivity of terrestrial gravitational-wave detectors below 20 Hz is a long-standing challenge, limited by ground motion and inertial sensing noise. In this Letter, we demonstrate ultra-high-vacuum compatible inertial isolation and position sensing technologies that achieve active platform stabilization down to 10 mHz. Our laser position sensors reach a sub − pm / Hz sensitivity above 10 mHz, independent of the input light polarization, representing a 100-fold improvement over the current LIGO position sensors. In addition, our inertial sensors provide at least a factor of 5 improvement in low-frequency sensitivity compared to state-of-the-art commercial seismometers. We integrate these technologies into a LIGO-like interferometer model and predict a low-frequency sensitivity improvement of up to an order of magnitude at 10 Hz, with enhanced linearity and calibration stability. This extension increases the detection horizon for intermediate-mass black hole binaries of mass 10 3 M ⊙ by a factor of 3 and increases the SNR for all lower mass binaries. Our results provide the first experimental demonstration of a practical pathway to sub-10 Hz operation of terrestrial gravitational-wave detectors and establish key technologies for next-generation observatories such as Cosmic Explorer and Einstein Telescope.
- 10 June 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (3)
Open AccessExtending ground-based gravitational-wave sensitivity to 5 Hz
Extending the sensitivity of terrestrial gravitational-wave detectors below 20 Hz is a long-standing challenge, limited by ground motion and inertial sensing noise. In this Letter, we demonstrate ultra-high-vacuum compatible inertial isolation and position sensing technologies that achieve active platform stabilization down to 10 mHz. Our laser position sensors reach a sub − pm / Hz sensitivity above 10 mHz, independent of the input light polarization, representing a 100-fold improvement over the current LIGO position sensors. In addition, our inertial sensors provide at least a factor of 5 improvement in low-frequency sensitivity compared to state-of-the-art commercial seismometers. We integrate these technologies into a LIGO-like interferometer model and predict a low-frequency sensitivity improvement of up to an order of magnitude at 10 Hz, with enhanced linearity and calibration stability. This extension increases the detection horizon for intermediate-mass black hole binaries of mass 10 3 M ⊙ by a factor of 3 and increases the SNR for all lower mass binaries. Our results provide the first experimental demonstration of a practical pathway to sub-10 Hz operation of terrestrial gravitational-wave detectors and establish key technologies for next-generation observatories such as Cosmic Explorer and Einstein Telescope.
- Open Access
- 5 February 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 23 (2)
Sensitivity and control of a six-axis fused-silica seismometer
We present a pair of seismometers capable of measurement in all six axes of rigid motion. The vacuum-compatible devices implement compact interferometric displacement sensors to surpass the sensitivity of typical electrical-readout schemes. Together with the capability to subtract the sensitivity-limiting coupling of ground tilt into horizontal motion, our seismometers can widen the sensing band toward megahertz frequencies. This has notable applications across a range of fields requiring access to low-frequency signals, such as seismology and climate research. We particularly highlight their potential application in gravitational-wave observatories (the Laser Interferometer Gravitational-Wave Observatory, LIGO) in improving their observation capability of intermediate-mass black holes (approximately 1000 M ⊙ ). The sensors are based on a near-monolithic fused-silica design consisting of a fused-silica mass and fiber, showing improved stability and robustness to tilt drifts, alignment, and control compared to all-metal or mixed metal-silica designs. We demonstrate tilt sensitivity that surpasses the best commercial alternatives in a significantly reduced footprint compared to our previous iterations of these sensors.
- 5 February 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 23 (2)
Open AccessSensitivity and control of a six-axis fused-silica seismometer
We present a pair of seismometers capable of measurement in all six axes of rigid motion. The vacuum-compatible devices implement compact interferometric displacement sensors to surpass the sensitivity of typical electrical-readout schemes. Together with the capability to subtract the sensitivity-limiting coupling of ground tilt into horizontal motion, our seismometers can widen the sensing band toward megahertz frequencies. This has notable applications across a range of fields requiring access to low-frequency signals, such as seismology and climate research. We particularly highlight their potential application in gravitational-wave observatories (the Laser Interferometer Gravitational-Wave Observatory, LIGO) in improving their observation capability of intermediate-mass black holes (approximately 1000 M ⊙ ). The sensors are based on a near-monolithic fused-silica design consisting of a fused-silica mass and fiber, showing improved stability and robustness to tilt drifts, alignment, and control compared to all-metal or mixed metal-silica designs. We demonstrate tilt sensitivity that surpasses the best commercial alternatives in a significantly reduced footprint compared to our previous iterations of these sensors.
- 7 March 2017
- Published by Seismological Society of America (SSA) in Bulletin of the Seismological Society of America
- Vol. 107 (2) , 709-717
Subtracting Tilt from a Horizontal Seismometer Using a Ground‐Rotation Sensor
- 7 March 2017
- Published by Seismological Society of America (SSA) in Bulletin of the Seismological Society of America
- Vol. 107 (2) , 709-717
Subtracting Tilt from a Horizontal Seismometer Using a Ground‐Rotation Sensor
- 29 September 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5500, 194-206
Low-frequency active vibration isolation for advanced LIGO
LIGO is dedicated to the detection of gravitational waves. To achieve the design sensitivity of the proposed Advanced LIGO detectors, the seismic isolation system is required to isolate the interferometer mirrors from ground motion above 0.1 Hz. The dominant source of motion above 0.1 Hz is the microseismic peaks near 0.15 Hz. The system needs to isolate the payload from this motion by at least a factor of five in all three translational degrees of freedom. Tilt-horizontal coupling is the most challenging problem for seismic isolation below 1 Hz. Tilt-horizontal coupling results from the principle of equivalence: inertial horizontal sensors cannot distinguish horizontal acceleration from tilt motion. Tilt-horizontal coupling rises dramatically at low frequencies, which makes low frequency isolation difficult. Several techniques are used to address the tilt-horizontal coupling problem. The isolation platform is designed to separate horizontal motions from tilt motions. Feedback control to displacement sensors is used to command the platform in all degrees of freedom. These sensors are "corrected" by ground seismometers, using an optimal FIR filtering technique to separate tilt noise from horizontal acceleration. With these techniques, we obtained isolation factors of 10 to 20 simultaneously in all three degrees of freedom at 0.15 Hz.
- 29 September 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5500, 194-206
Low-frequency active vibration isolation for advanced LIGO
LIGO is dedicated to the detection of gravitational waves. To achieve the design sensitivity of the proposed Advanced LIGO detectors, the seismic isolation system is required to isolate the interferometer mirrors from ground motion above 0.1 Hz. The dominant source of motion above 0.1 Hz is the microseismic peaks near 0.15 Hz. The system needs to isolate the payload from this motion by at least a factor of five in all three translational degrees of freedom. Tilt-horizontal coupling is the most challenging problem for seismic isolation below 1 Hz. Tilt-horizontal coupling results from the principle of equivalence: inertial horizontal sensors cannot distinguish horizontal acceleration from tilt motion. Tilt-horizontal coupling rises dramatically at low frequencies, which makes low frequency isolation difficult. Several techniques are used to address the tilt-horizontal coupling problem. The isolation platform is designed to separate horizontal motions from tilt motions. Feedback control to displacement sensors is used to command the platform in all degrees of freedom. These sensors are "corrected" by ground seismometers, using an optimal FIR filtering technique to separate tilt noise from horizontal acceleration. With these techniques, we obtained isolation factors of 10 to 20 simultaneously in all three degrees of freedom at 0.15 Hz.