Yu Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yu Song has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Zhenping Feng
Xi’an Jiaotong University
3 shared publications - Zhao Liu
School of Energy and Power Engineering, Xi'an Jiaotong University , Xi'an 710049, China
2 shared publications - Huimin Xiang
School of Power and Energy, Northwestern Polytechnical University, Xi’an 710129, China
1 shared publication L. Chen
School of Power and Energy, Northwestern Polytechnical University, Xi’an 710129, China
1 shared publicationQ. Yang
School of Power and Energy, Northwestern Polytechnical University, Xi’an 710129, China
1 shared publicationWeixin Zhang
1 shared publication
Latest Publications
- 1 December 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (12)
Interaction and combined cooling effects of mid-passage gap leakage with blade coolant in suction side and corner cooling
With the increase in turbine inlet temperatures, effective cooling is essential for all regions of the turbine. However, most previous studies have focused on the thermal protection of individual components, often neglecting marginal areas. From the perspective of multi-zone interactions within the cascades, this study numerically investigates the combined cooling effects between mid-passage gap (MPG) leakage and blade coolant, with a focus on the suction side (SS) and corner cooling. An interesting corner cooling phenomenon is observed, involving interactions among the blade film coolant, leakage flow, and secondary flow. Results show that corner cooling is enhanced when the coolant is either guided by a counter leakage vortex or when the vortex is weakened by leakage. The combined effects of MPG leakage and blade coolant expand the cooling coverage on the suction side and contribute to achieving full surface thermal protection. Additionally, while a compound angle improves blade cooling, its effect is limited and mainly improves the peak value of laterally-averaged cooling effectiveness (ηl). When the blowing ratio of blade coolant (Mb) increases from 0.5 to 1.5 at leakage mass flow rate (MFRg) = 1%, the peak value of ηl on the blade suction side increases by 51%. Under this condition, when film holes are with a compound angle (β) value of 30°, the peak value of ηl further increases by 17.9%. These findings highlight the importance of considering the synergistic effects of passage vortices and leakage flows in future blade cooling designs to achieve more comprehensive and effective suction-side coverage.
- 1 December 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (12)
Interaction and combined cooling effects of mid-passage gap leakage with blade coolant in suction side and corner cooling
With the increase in turbine inlet temperatures, effective cooling is essential for all regions of the turbine. However, most previous studies have focused on the thermal protection of individual components, often neglecting marginal areas. From the perspective of multi-zone interactions within the cascades, this study numerically investigates the combined cooling effects between mid-passage gap (MPG) leakage and blade coolant, with a focus on the suction side (SS) and corner cooling. An interesting corner cooling phenomenon is observed, involving interactions among the blade film coolant, leakage flow, and secondary flow. Results show that corner cooling is enhanced when the coolant is either guided by a counter leakage vortex or when the vortex is weakened by leakage. The combined effects of MPG leakage and blade coolant expand the cooling coverage on the suction side and contribute to achieving full surface thermal protection. Additionally, while a compound angle improves blade cooling, its effect is limited and mainly improves the peak value of laterally-averaged cooling effectiveness (ηl). When the blowing ratio of blade coolant (Mb) increases from 0.5 to 1.5 at leakage mass flow rate (MFRg) = 1%, the peak value of ηl on the blade suction side increases by 51%. Under this condition, when film holes are with a compound angle (β) value of 30°, the peak value of ηl further increases by 17.9%. These findings highlight the importance of considering the synergistic effects of passage vortices and leakage flows in future blade cooling designs to achieve more comprehensive and effective suction-side coverage.
- 17 March 2025
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 61
Investigation on the cooling characteristic of turbine endwall with mid-passage gap misalignment
- 17 March 2025
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 61
Investigation on the cooling characteristic of turbine endwall with mid-passage gap misalignment
- 12 February 2025
- Published by Cambridge University Press (CUP) in The Aeronautical Journal
- Vol. 129 (1337) , 1982-2003
Infrared radiation characteristics of an aero-engine binary plug nozzle with various slot cooling configurations
For binary plug nozzle, the plug cone is exposed to high-temperature mainstream flow, making it one of the nozzle’s high-temperature components. This paper uses the Realizable k-ε turbulence model and the reverse Monte Carlo method to numerically investigate the aerodynamic and infrared radiation characteristics of the plug nozzle. Various slot cooling configurations were adopted to study the nozzle’s infrared radiation in detail. Results indicate that compared to the baseline nozzle, the plug nozzle’s performance is slightly reduced due to the decrease in effective area of flow over the plug cone. Introducing slot cooling at the rear edge provides significant infrared suppression benefits at low detection angles and notably reduces infrared radiation discrepancy with baseline nozzle at high detection angles. The cooling air from slots causes the nozzle jet to exhibit a ‘thermal layered’ feature. With the same total coolant mass flow, the ‘leading edge + trailing edge’ cooling configuration can lower the area-averaged wall temperature of the plug cone by 5.5% – 12.3%. However, its infrared radiation intensity at each detection angle on the pitch detection plane is higher than that of the ‘trailing edge’ configuration. The significance of leading-edge cooling is focused more on thermal protection for the plug. Thus, it is essential to balance coolant mass flow distribution between infrared radiation suppression and thermal protection.
- 12 February 2025
- Published by Cambridge University Press (CUP) in The Aeronautical Journal
- Vol. 129 (1337) , 1982-2003
Infrared radiation characteristics of an aero-engine binary plug nozzle with various slot cooling configurations
For binary plug nozzle, the plug cone is exposed to high-temperature mainstream flow, making it one of the nozzle’s high-temperature components. This paper uses the Realizable k-ε turbulence model and the reverse Monte Carlo method to numerically investigate the aerodynamic and infrared radiation characteristics of the plug nozzle. Various slot cooling configurations were adopted to study the nozzle’s infrared radiation in detail. Results indicate that compared to the baseline nozzle, the plug nozzle’s performance is slightly reduced due to the decrease in effective area of flow over the plug cone. Introducing slot cooling at the rear edge provides significant infrared suppression benefits at low detection angles and notably reduces infrared radiation discrepancy with baseline nozzle at high detection angles. The cooling air from slots causes the nozzle jet to exhibit a ‘thermal layered’ feature. With the same total coolant mass flow, the ‘leading edge + trailing edge’ cooling configuration can lower the area-averaged wall temperature of the plug cone by 5.5% – 12.3%. However, its infrared radiation intensity at each detection angle on the pitch detection plane is higher than that of the ‘trailing edge’ configuration. The significance of leading-edge cooling is focused more on thermal protection for the plug. Thus, it is essential to balance coolant mass flow distribution between infrared radiation suppression and thermal protection.