Sai Kushal Kumar Solleti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sai Kushal Kumar Solleti has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Amoor S. Vishwanathan
WATER Laboratory, Department of Biosciences, Sri Sathya Sai Institute of Higher Learning, Prasanthi Nilayam, Puttaparthi 515134, Andhra Pradesh, India
1 shared publication - Arun Sai Kumar Peketi
Sri Sathya Sai Institute of Higher Learning
1 shared publication - Eswarappa Pradeep Bulagonda
Department of Biosciences, Sri Sathya Sai Institute of Higher Learning, Puttaparthi, India
1 shared publication P Kennedy Kumar
1 shared publication- S. K. Shakthi Thangavel
WATER Laboratory, Department of Biosciences, Sri Sathya Sai Institute of Higher Learning, Prasanthi Nilayam, Puttaparthi, Andhra Pradesh, 515134, India
1 shared publication - Sahashransu Satyajeet Mahapatra
WATER Laboratory, Department of Biosciences, Sri Sathya Sai Institute of Higher Learning, Puttaparthi, India
1 shared publication
Latest Publications
- Open Access
- 8 December 2025
- Published by Portland Press Ltd. in Emerging Topics in Life Sciences
- Vol. 9 (2) , 47-54
Electrifying the UNSDGs with microbial power
Water stress represents a critical global challenge demanding innovative solutions for effective water resource management. Microbial electrochemical technologies (METs) leverage bacterial extracellular electron transfer for addressing issues related to water stress. These technologies exhibit a diverse range of applications, positioning them as integral to sustainable development through effective water resource management. Their versatility allows them to function as key contributors to achieving the United Nations Sustainable Development Goals (UNSDGs). Through their application, METs offer promising strategies for mitigating pollution, recovering valuable resources, and enabling real-time water quality monitoring. Employing these technologies facilitates the concurrent addressing of various UNSDGs, fostering a holistic and integrated approach. METs present opportunities for decentralized wastewater treatment and reuse, thereby promoting accessibility to clean water and sanitation, particularly in marginalized communities. However, the realization of these benefits faces significant challenges, including technological scalability, optimization, and regulatory frameworks. Overcoming these obstacles is crucial for harnessing the full potential of METs to meet UNSDGs. This perspective article underscores the imperative of further research, collaboration, and policy support to propel METs towards becoming a cornerstone in the sustainable management of water resources and the achievement of UNSDGs on a global scale.
- 8 December 2025
- Published by Portland Press Ltd. in Emerging Topics in Life Sciences
- Vol. 9 (2) , 47-54
Open AccessElectrifying the UNSDGs with microbial power
Water stress represents a critical global challenge demanding innovative solutions for effective water resource management. Microbial electrochemical technologies (METs) leverage bacterial extracellular electron transfer for addressing issues related to water stress. These technologies exhibit a diverse range of applications, positioning them as integral to sustainable development through effective water resource management. Their versatility allows them to function as key contributors to achieving the United Nations Sustainable Development Goals (UNSDGs). Through their application, METs offer promising strategies for mitigating pollution, recovering valuable resources, and enabling real-time water quality monitoring. Employing these technologies facilitates the concurrent addressing of various UNSDGs, fostering a holistic and integrated approach. METs present opportunities for decentralized wastewater treatment and reuse, thereby promoting accessibility to clean water and sanitation, particularly in marginalized communities. However, the realization of these benefits faces significant challenges, including technological scalability, optimization, and regulatory frameworks. Overcoming these obstacles is crucial for harnessing the full potential of METs to meet UNSDGs. This perspective article underscores the imperative of further research, collaboration, and policy support to propel METs towards becoming a cornerstone in the sustainable management of water resources and the achievement of UNSDGs on a global scale.
- Open Access
Exploiting Zeta potential of air borne pathogenic bacteria for effective air decontamination
Background: Airborne microorganisms contribute significantly to hospital-associated infections (HAIs), particularly causing respiratory tract infections (RTIs). Multi-drug resistant (MDR) airborne pathogens pose a global clinical threat, challenging existing air decontamination technologies. While current methods effectively trap microbes, they often lack microbicidal properties. Exploitation of Zeta potential of microbes which are naturally charged could be a potential strategy for air decontamination, independent of their antimicrobial resistance. In this study, we tested the efficacy of ZeBox technology which relies on zeta potential to trap and eliminate airborne pathogens such as clinically isolated, MDR Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, Escherichia coli of respiratory origin and a non RTI isolate Staphylococcus aureus . Methods: Five MDR bacterial pathogens which include K. pneumoniae (2 nos), A. baumannii, P. aeruginosa , and E. coli from patients with RTI and one pus isolate of S. aureus were included in the study. These isolates were aerosolized in a certified BSL-2 setting containing a ZeBox-powered Air Sterilization device. Viable bacteria were enumerated before and after exposure to the Zebox powered device. Clinical and laboratory isolated bacterial strains were assessed for zeta potential variations to understand its association with antibiotic resistance and pathogenicity. Results: Our analyses revealed that Zeta potential is species specific, but independent of the pathogenicity and antibiotic susceptibility of the tested bacteria. Exposure to Zebox powered device for 5 mins resulted in a remarkable decline of microbial load with a minimum 5 log reduction (99.999%) of all the tested isolates, irrespective of their species. Zeta potential measurements further indicated a consistent killing mechanism of MDR pathogens by Zebox technology. Conclusions: The current study underscores the reliability of zeta potential based air decontamination strategies for potential elimination of diverse, air borne MDR bacteria in healthcare settings. Highlights: Zeta potential value of bacteria is not influenced by AST or pathogenicity of bacteria. Zeta potential driven device traps and kills airborne MDR bacteria with 99.999% efficiency. The efficacy of ZeBox technology is consistent across pathogens.
Open AccessExploiting Zeta potential of air borne pathogenic bacteria for effective air decontamination
Background: Airborne microorganisms contribute significantly to hospital-associated infections (HAIs), particularly causing respiratory tract infections (RTIs). Multi-drug resistant (MDR) airborne pathogens pose a global clinical threat, challenging existing air decontamination technologies. While current methods effectively trap microbes, they often lack microbicidal properties. Exploitation of Zeta potential of microbes which are naturally charged could be a potential strategy for air decontamination, independent of their antimicrobial resistance. In this study, we tested the efficacy of ZeBox technology which relies on zeta potential to trap and eliminate airborne pathogens such as clinically isolated, MDR Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, Escherichia coli of respiratory origin and a non RTI isolate Staphylococcus aureus . Methods: Five MDR bacterial pathogens which include K. pneumoniae (2 nos), A. baumannii, P. aeruginosa , and E. coli from patients with RTI and one pus isolate of S. aureus were included in the study. These isolates were aerosolized in a certified BSL-2 setting containing a ZeBox-powered Air Sterilization device. Viable bacteria were enumerated before and after exposure to the Zebox powered device. Clinical and laboratory isolated bacterial strains were assessed for zeta potential variations to understand its association with antibiotic resistance and pathogenicity. Results: Our analyses revealed that Zeta potential is species specific, but independent of the pathogenicity and antibiotic susceptibility of the tested bacteria. Exposure to Zebox powered device for 5 mins resulted in a remarkable decline of microbial load with a minimum 5 log reduction (99.999%) of all the tested isolates, irrespective of their species. Zeta potential measurements further indicated a consistent killing mechanism of MDR pathogens by Zebox technology. Conclusions: The current study underscores the reliability of zeta potential based air decontamination strategies for potential elimination of diverse, air borne MDR bacteria in healthcare settings. Highlights: Zeta potential value of bacteria is not influenced by AST or pathogenicity of bacteria. Zeta potential driven device traps and kills airborne MDR bacteria with 99.999% efficiency. The efficacy of ZeBox technology is consistent across pathogens.