V. I. Korobeinikova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
V. I. Korobeinikova has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
A.A. Ufandeev
Siberian State Med Univ, Ctr Preclin Res, Cent Res Lab, 2 Moskovsky Trakt St, Tomsk 634050, Russia
1 shared publicationD.V. Vasilchenko
Siberian State Med Univ, Dept Pathol Anat, 2 Moskovsky Trakt St, Tomsk 634050, Russia
1 shared publicationE.A. Avdoshina
Siberian State Med Univ, Dept Hosp Surg, Course Cardiovasc Surg, 2 Moskovsky Trakt St, Tomsk 634050, Russia
1 shared publication- Elena A. Bolshevich
National Research Tomsk State University, Tomsk, Russian Federation
1 shared publication G.Ts. Dambaev
Siberian State Med Univ, Dept Hosp Surg, Course Cardiovasc Surg, 2 Moskovsky Trakt St, Tomsk 634050, Russia
1 shared publicationM.M. Soloviev
Siberian State Med Univ, Dept Hosp Surg, Course Cardiovasc Surg, 2 Moskovsky Trakt St, Tomsk 634050, Russia
1 shared publication
Latest Publications
- 1 January 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (1) , 9-15
Structure of thin TiNi wires and fiber-based surgical implants
- 1 January 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (1) , 9-15
Structure of thin TiNi wires and fiber-based surgical implants
- Open Access
- 27 December 2023
- Published by Journal Sovremennye Tehnologii v Medicine in Sovremennye tehnologii v medicine
- Vol. 15 (6) , 49-60
Valve Formation during Colostomy by Means of Spherical Implants Based on Titanium Nickelide Both Wrapping and Non-Wrapping the Serous-Muscular Layer of the Intestine
Imposition of a classic colostomy does not allow to control the passage of intestinal discharge. This shortcoming provides rationale for development of new materials for implants, as well as new techniques for valve formation. The aim of the study is to assess the possibility of using spherical implants based on titanium nickelide both wrapping and non-wrapping the serous-muscular layer of the intestine for valve formation during colostomy. Materials and Methods. Experiments were performed on 45 male Wistar rats with the average body weight of 587 +/- 10 g. Depending on the type of surgical intervention, all animals were divided into three groups. In the control group (n=15), a classic end colostomy was formed without spherical implants. In test group 1 (n=15), colostomy was formed using spherical implants made of titanium nickelide with wrapping the serous-muscular layer of the intestine; in test group 2 ( n=15), the same procedure was performed without wrapping the serous-muscular layer. To assess the clinical condition of the animals, the authors monitored the body weight dynamics, food and water consumption, signs of discharge from the stoma, and recorded complications. The animals were euthanized on day 7, day 30, and day 60 of the experiment. During necropsy, the condition of the abdominal organs was assessed macroscopically with a special attention to the signs of adhesions. The severity of the inflammatory process in the area of surgical intervention was assessed histologically. Results. The survival rate in three groups was 100%. In the group with the formation of a colostomy non-wrapping the serous-muscular layer, a good effect of regeneration in the stoma area was shown, the connection of the skin flap and the intestinal wall was complete. Macroscopically, adhesions and inflammatory processes of the peritoneum in the control and two test groups were minimal. Conclusion. The present study shows the advantage of experimental modeling of colostomy using spherical titanium nickelide implants non-wrapping the serous-muscular layer of the colon compared to classical formation of colostomy. At that, wrapping the serous-muscular layer of the colon using spherical titanium nickelide implants is behind classical formation of a colostomy.
- 27 December 2023
- Published by Journal Sovremennye Tehnologii v Medicine in Sovremennye tehnologii v medicine
- Vol. 15 (6) , 49-60
Open AccessValve Formation during Colostomy by Means of Spherical Implants Based on Titanium Nickelide Both Wrapping and Non-Wrapping the Serous-Muscular Layer of the Intestine
Imposition of a classic colostomy does not allow to control the passage of intestinal discharge. This shortcoming provides rationale for development of new materials for implants, as well as new techniques for valve formation. The aim of the study is to assess the possibility of using spherical implants based on titanium nickelide both wrapping and non-wrapping the serous-muscular layer of the intestine for valve formation during colostomy. Materials and Methods. Experiments were performed on 45 male Wistar rats with the average body weight of 587 +/- 10 g. Depending on the type of surgical intervention, all animals were divided into three groups. In the control group (n=15), a classic end colostomy was formed without spherical implants. In test group 1 (n=15), colostomy was formed using spherical implants made of titanium nickelide with wrapping the serous-muscular layer of the intestine; in test group 2 ( n=15), the same procedure was performed without wrapping the serous-muscular layer. To assess the clinical condition of the animals, the authors monitored the body weight dynamics, food and water consumption, signs of discharge from the stoma, and recorded complications. The animals were euthanized on day 7, day 30, and day 60 of the experiment. During necropsy, the condition of the abdominal organs was assessed macroscopically with a special attention to the signs of adhesions. The severity of the inflammatory process in the area of surgical intervention was assessed histologically. Results. The survival rate in three groups was 100%. In the group with the formation of a colostomy non-wrapping the serous-muscular layer, a good effect of regeneration in the stoma area was shown, the connection of the skin flap and the intestinal wall was complete. Macroscopically, adhesions and inflammatory processes of the peritoneum in the control and two test groups were minimal. Conclusion. The present study shows the advantage of experimental modeling of colostomy using spherical titanium nickelide implants non-wrapping the serous-muscular layer of the colon compared to classical formation of colostomy. At that, wrapping the serous-muscular layer of the colon using spherical titanium nickelide implants is behind classical formation of a colostomy.