Lu Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lu Yang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Feng Zhou
School of Earth Sciences, Hebei GEO University, Shijiazhuang 050031, China
1 shared publication - Gaofan Yue
Institute of Hydrogeology and Environmental Geology, Chinese Academy of Geological Sciences, Shijiazhuang 050061, China
1 shared publication - Hao Zhu
School of Water Resources & Environmental Engineering, East China University of Technology, Nanchang 330013, China
1 shared publication - Wenjing Lin
Institute of Hydrogeology and Environmental Geology, Chinese Academy of Geological Sciences, China
1 shared publication - Yaru Wang
Institute of Hydrogeology and Environmental Geology, Chinese Academy of Geological Sciences, Shijiazhuang 050061, China
1 shared publication - Zhining Liu
Inner Mongolia Mining Co., Ltd., China National Nuclear Corporation, Hohhot 010010, China
1 shared publication
Latest Publications
- Open Access
- 14 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (4) , 1982
Preliminary Prediction of Temperature Field and Thermal Hazards in the Water Diversion Tunnel of the “Yellow River to Xining” Project
As tunnel engineering advances towards greater depths, larger scales, and longer distances, high rock temperatures and tunnel thermal damage frequently occur, constituting some of the main geological hazards faced by transportation, water conservancy, and other tunnel engineering projects. In this study, we take the alternative option to the No.1 deep-buried water diversion tunnel of the “Diversion of Yellow River to Jining” project as the study area, combined with the geological data of the field investigation, to comprehensively consider the thermodynamic properties of the rocks along the tunnel and the logging data along the tunnel, and we use the least squares method to fit the temperature of the logging wells to obtain the thermal background parameters of the earth’s heat flow as well as other regional heat background parameters to obtain the thermal background parameters of the tunnel. The COMSOL Multiphysics software established a two-dimensional steady-state geothermal field numerical model to predict the rock temperature along the tunnel. The results show that the maximum temperature along the tunnel is 51.1 °C, the length of the tunnel with thermal damage class I is 45.9 km, the length of the tunnel with thermal damage class II is 18.4 km, the length of the tunnel with thermal damage class III is 8.0 km, and the length of the tunnel with thermal damage class IV is predicted to be 0.18 km. Compared with the on-site temperature measurement data, the model prediction error is within ±1.5 °C, which validates the accuracy of the model. This study adopts numerical simulation combined with field geological and logging data to provide a theoretical basis for tunnel heat hazard prevention. Meanwhile, it offers technical support for the design and construction of similar deep-buried high-temperature tunnels.
- 14 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (4) , 1982
Open AccessPreliminary Prediction of Temperature Field and Thermal Hazards in the Water Diversion Tunnel of the “Yellow River to Xining” Project
As tunnel engineering advances towards greater depths, larger scales, and longer distances, high rock temperatures and tunnel thermal damage frequently occur, constituting some of the main geological hazards faced by transportation, water conservancy, and other tunnel engineering projects. In this study, we take the alternative option to the No.1 deep-buried water diversion tunnel of the “Diversion of Yellow River to Jining” project as the study area, combined with the geological data of the field investigation, to comprehensively consider the thermodynamic properties of the rocks along the tunnel and the logging data along the tunnel, and we use the least squares method to fit the temperature of the logging wells to obtain the thermal background parameters of the earth’s heat flow as well as other regional heat background parameters to obtain the thermal background parameters of the tunnel. The COMSOL Multiphysics software established a two-dimensional steady-state geothermal field numerical model to predict the rock temperature along the tunnel. The results show that the maximum temperature along the tunnel is 51.1 °C, the length of the tunnel with thermal damage class I is 45.9 km, the length of the tunnel with thermal damage class II is 18.4 km, the length of the tunnel with thermal damage class III is 8.0 km, and the length of the tunnel with thermal damage class IV is predicted to be 0.18 km. Compared with the on-site temperature measurement data, the model prediction error is within ±1.5 °C, which validates the accuracy of the model. This study adopts numerical simulation combined with field geological and logging data to provide a theoretical basis for tunnel heat hazard prevention. Meanwhile, it offers technical support for the design and construction of similar deep-buried high-temperature tunnels.