Iske De Backer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Iske De Backer has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Luc Van Os
Department of Ophthalmology, Antwerp University Hospital, Antwerp, Belgium
2 shared publications - Marie-José Tassignon
Department of Ophthalmology, Antwerp University Hospital, University of Antwerp, Antwerp, Belgium
2 shared publications - Michiel Taal
Department of Ophthalmology, Antwerp University Hospital, B-2650 Edegem, Belgium
2 shared publications
Latest Publications
- Open Access
- 21 March 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (7) , 2138
Prospective Case Series of Low-Energy Femtosecond Laser-Assisted Cataract Surgery in Pediatric Patients
Background/Objectives: We report a consecutive prospective case series to obtain prospective safety and performance data of a low-energy femtosecond (FS)-laser for cataract surgery in children and to evaluate the applicability of the Bochum formula for capsulotomy diameter calculation. Methods: In pediatric lens surgery with implantation of a bag-in-the-lens intraocular lens (BIL IOL), anterior capsulotomies were performed using the FS-laser. Regression analysis was used to develop an age-dependent correction formula, and the Pearson correlation was used to evaluate the applicability of the Bochum formula. Surgery-related and ocular adverse events (AE) were recorded at 1 day, 1 week, 1 month, and 6 months postoperatively. Results: Thirteen eyes of 10 patients were included in the analysis, among them three cases of subluxated lenses. The mean age was 3.10 ± 2.38 years (range: 4 months to 8 years). The linear bivalent regression yielded the following formula: 1.27 − 0.014 × patient age. Age-related formulas, such as the Bochum formula, are required to calculate the programmed capsulotomy diameter. No complications related to the FS-laser or ocular AEs were observed up to six months; in particular, no excessive shrinkage, retinal detachment, or unusual inflammation were identified. Conclusions: This study indicates that the use of the low-energy femtosecond laser for anterior capsulotomy in pediatric lens surgery is safe and contributes to improved reliability and feasibility. The confirmed age dependence of the enlargement factor of the capsulotomy diameter might be related to the higher capsular elasticity in pediatric eyes.
- 21 March 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (7) , 2138
Open AccessProspective Case Series of Low-Energy Femtosecond Laser-Assisted Cataract Surgery in Pediatric Patients
Background/Objectives: We report a consecutive prospective case series to obtain prospective safety and performance data of a low-energy femtosecond (FS)-laser for cataract surgery in children and to evaluate the applicability of the Bochum formula for capsulotomy diameter calculation. Methods: In pediatric lens surgery with implantation of a bag-in-the-lens intraocular lens (BIL IOL), anterior capsulotomies were performed using the FS-laser. Regression analysis was used to develop an age-dependent correction formula, and the Pearson correlation was used to evaluate the applicability of the Bochum formula. Surgery-related and ocular adverse events (AE) were recorded at 1 day, 1 week, 1 month, and 6 months postoperatively. Results: Thirteen eyes of 10 patients were included in the analysis, among them three cases of subluxated lenses. The mean age was 3.10 ± 2.38 years (range: 4 months to 8 years). The linear bivalent regression yielded the following formula: 1.27 − 0.014 × patient age. Age-related formulas, such as the Bochum formula, are required to calculate the programmed capsulotomy diameter. No complications related to the FS-laser or ocular AEs were observed up to six months; in particular, no excessive shrinkage, retinal detachment, or unusual inflammation were identified. Conclusions: This study indicates that the use of the low-energy femtosecond laser for anterior capsulotomy in pediatric lens surgery is safe and contributes to improved reliability and feasibility. The confirmed age dependence of the enlargement factor of the capsulotomy diameter might be related to the higher capsular elasticity in pediatric eyes.
- Open Access
- 16 February 2025
- Published by MDPI AG in Preprints.org
Prospective Case Series of Low-Energy Femtosecond Laser-Assisted Cataract Surgery in Pediatric Patients
Background/Objectives : We report a consecutive prospective case series to obtain prospective safety and performance data of a low-energy femtosecond (FS)-laser for cataract surgery in children and to evaluate the applicability of the Bochum formula for capsulotomy diameter calculation. Methods: In pediatric lens surgery with implantation of a bag-in-the-lens intraocular lens (BIL IOL), anterior capsulotomies were performed using the FS-laser. Regression analysis was used to develop an age-dependent correction formula. Pearson correlation was used to evaluate applicability of the Bochum formula. Surgery related and ocular adverse events (AE) were recorded at 1 day, 1 week, 1 month, and 6 months postoperatively. Results: Thirteen eyes of 10 patients were included in analysis, among them 3 cases of subluxated lenses. The mean (SD) age was 3.10 ± 2.38 years (range: 4 months to 8 years). The linear bivalent regression yielded following formula: 1.27 – 0.014 x patient age. Age-related formulas such as the Bochum formula are required to calculate the programmed capsulotomy diameter. No complications related to the FS-laser or ocular AEs were observed up to six months; in particular no excessive shrinkage, retinal detachment or unusual inflammation were identified. Conclusions: This study indicates that the use of the low-energy femtosecond laser for anterior capsulotomy in pediatric lens surgery is safe and contributes to improved reliability and feasibility. The confirmed age dependence of the enlargement factor of the capsulotomy diameter might be related to the higher capsular elasticity in pediatric eyes.
- 16 February 2025
- Published by MDPI AG in Preprints.org
Open AccessProspective Case Series of Low-Energy Femtosecond Laser-Assisted Cataract Surgery in Pediatric Patients
Background/Objectives : We report a consecutive prospective case series to obtain prospective safety and performance data of a low-energy femtosecond (FS)-laser for cataract surgery in children and to evaluate the applicability of the Bochum formula for capsulotomy diameter calculation. Methods: In pediatric lens surgery with implantation of a bag-in-the-lens intraocular lens (BIL IOL), anterior capsulotomies were performed using the FS-laser. Regression analysis was used to develop an age-dependent correction formula. Pearson correlation was used to evaluate applicability of the Bochum formula. Surgery related and ocular adverse events (AE) were recorded at 1 day, 1 week, 1 month, and 6 months postoperatively. Results: Thirteen eyes of 10 patients were included in analysis, among them 3 cases of subluxated lenses. The mean (SD) age was 3.10 ± 2.38 years (range: 4 months to 8 years). The linear bivalent regression yielded following formula: 1.27 – 0.014 x patient age. Age-related formulas such as the Bochum formula are required to calculate the programmed capsulotomy diameter. No complications related to the FS-laser or ocular AEs were observed up to six months; in particular no excessive shrinkage, retinal detachment or unusual inflammation were identified. Conclusions: This study indicates that the use of the low-energy femtosecond laser for anterior capsulotomy in pediatric lens surgery is safe and contributes to improved reliability and feasibility. The confirmed age dependence of the enlargement factor of the capsulotomy diameter might be related to the higher capsular elasticity in pediatric eyes.