IBIske De Backer

Iske De Backer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Iske De Backer has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Prospective Case Series of Low-Energy Femtosecond Laser-Assisted Cataract Surgery in Pediatric Patients

    by Luc Van Os, Iske De Backer, Michiel Taal, Marie-José Tassignon

    Background/Objectives: We report a consecutive prospective case series to obtain prospective safety and performance data of a low-energy femtosecond (FS)-laser for cataract surgery in children and to evaluate the applicability of the Bochum formula for capsulotomy diameter calculation. Methods: In pediatric lens surgery with implantation of a bag-in-the-lens intraocular lens (BIL IOL), anterior capsulotomies were performed using the FS-laser. Regression analysis was used to develop an age-dependent correction formula, and the Pearson correlation was used to evaluate the applicability of the Bochum formula. Surgery-related and ocular adverse events (AE) were recorded at 1 day, 1 week, 1 month, and 6 months postoperatively. Results: Thirteen eyes of 10 patients were included in the analysis, among them three cases of subluxated lenses. The mean age was 3.10 ± 2.38 years (range: 4 months to 8 years). The linear bivalent regression yielded the following formula: 1.27 − 0.014 × patient age. Age-related formulas, such as the Bochum formula, are required to calculate the programmed capsulotomy diameter. No complications related to the FS-laser or ocular AEs were observed up to six months; in particular, no excessive shrinkage, retinal detachment, or unusual inflammation were identified. Conclusions: This study indicates that the use of the low-energy femtosecond laser for anterior capsulotomy in pediatric lens surgery is safe and contributes to improved reliability and feasibility. The confirmed age dependence of the enlargement factor of the capsulotomy diameter might be related to the higher capsular elasticity in pediatric eyes.


  • Open Access

    Prospective Case Series of Low-Energy Femtosecond Laser-Assisted Cataract Surgery in Pediatric Patients

    by Luc Van Os, Iske De Backer, Michiel Taal, Marie-José Tassignon

    Background/Objectives : We report a consecutive prospective case series to obtain prospective safety and performance data of a low-energy femtosecond (FS)-laser for cataract surgery in children and to evaluate the applicability of the Bochum formula for capsulotomy diameter calculation. Methods: In pediatric lens surgery with implantation of a bag-in-the-lens intraocular lens (BIL IOL), anterior capsulotomies were performed using the FS-laser. Regression analysis was used to develop an age-dependent correction formula. Pearson correlation was used to evaluate applicability of the Bochum formula. Surgery related and ocular adverse events (AE) were recorded at 1 day, 1 week, 1 month, and 6 months postoperatively. Results: Thirteen eyes of 10 patients were included in analysis, among them 3 cases of subluxated lenses. The mean (SD) age was 3.10 ± 2.38 years (range: 4 months to 8 years). The linear bivalent regression yielded following formula: 1.27 – 0.014 x patient age. Age-related formulas such as the Bochum formula are required to calculate the programmed capsulotomy diameter. No complications related to the FS-laser or ocular AEs were observed up to six months; in particular no excessive shrinkage, retinal detachment or unusual inflammation were identified. Conclusions: This study indicates that the use of the low-energy femtosecond laser for anterior capsulotomy in pediatric lens surgery is safe and contributes to improved reliability and feasibility. The confirmed age dependence of the enlargement factor of the capsulotomy diameter might be related to the higher capsular elasticity in pediatric eyes.