Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ahmed Samir Elkattan has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • José López-López

    Department of Odontostomatology, Faculty of Medicine and Health Sciences (Dentistry) University of Barcelona Barcelona Spain

    3 shared publications
  • Mónica Blázquez-Hinarejos

    Faculty of Medicine and Health Sciences (Dentistry), University of Barcelona, 08907 L’Hospitalet de Llobregat, Spain

    3 shared publications
  • Abel García-García

    Oral Medicine, Oral Surgery, and Implantology Unit (MedOralRes), Faculty of Medicine and Dentistry, Universidade de Santiago de Compostela (USC). Calle Entrerríos s/n., Santiago de Compostela, Galicia, Spain; Foundation Health Research Institute of Santiago de Compostela (FIDIS). Av. Choupana s/n., Santiago de Compostela, Galicia, Spain

    1 shared publication
  • Andrés Blanco-Carrión

    Oral Medicine, Oral Surgery, and Implantology Unit (MedOralRes), Faculty of Medicine and Dentistry, Universidade de Santiago de Compostela (USC). Calle Entrerríos s/n., Santiago de Compostela, Galicia, Spain; Foundation Health Research Institute of Santiago de Compostela (FIDIS). Av. Choupana s/n., Santiago de Compostela, Galicia, Spain

    1 shared publication
  • Eva Otero-Rey

    Oral Medicine, Oral Surgery, and Implantology Unit (MedOralRes), Faculty of Medicine and Dentistry, Universidade de Santiago de Compostela, A Coruña, Spain

    1 shared publication
  • Francisco Javier Parra-Moreno

    Department of Odontostomatology, Faculty of Medicine and Health Sciences, School of Dentistry, University of Barcelona, Barcelona Dental Hospital [HOUB], Barcelona, Spain

    1 shared publication

Latest Publications

  • Open Access

    Within-Device Exposure-Setting and Voxel-Size Changes in CBCT Alveolar Bone Measurement for Implant Planning: A Systematic Review

    by Ahmed Samir Elkattan, Mónica Piña-Dabreu, Pere Riutord-Sbert, Mónica Blázquez-Hinarejos, José López-López, Hassan Ahmed Assiri, Angel Arturo López González

    Background: This review examined whether within-device exposure-setting or nominal voxel-size changes in cone-beam computed tomography (CBCT) affect linear alveolar bone measurements for implant planning, separating accuracy from agreement. Methods: Database-specific search strategies and retrieval counts are reported for PubMed/MEDLINE, Ovid Embase, Scopus, and Web of Science Core Collection. Study selection is presented in the updated PRISMA flow diagram. The reported International Prospective Register of Systematic Reviews (PROSPERO) identifier is CRD420261361509. Studies were grouped by outcome, protocol contrast, and experimental model. The Quality Assessment Tool for In Vitro Studies (QUIN) appraisal was performed by one reviewer. A revision-stage source and analysis-unit audit led to withdrawal of the planned inverse-variance meta-analyses and their ±0.5 mm equivalence claims; structured study-level synthesis was used instead. Results: Eight studies addressed linear measurements; two additional reports were retained only as methodological context. Seven linear-measurement studies compared protocols within a device, and one compared different devices. All were experimental. In one five-skull study, mean absolute errors were 0.50, 0.46, and 0.51 mm at 40, 20, and 7 s, respectively. A cadaver study reported mean absolute errors of approximately 1.10–1.20 mm. Small mean between-protocol differences sometimes coexisted with impaired anatomical visibility. Repeated observations were not equivalent to independent specimens, and several required sampling variances could not be reconstructed. Conclusions: Selected within-device protocol changes may preserve average measurements under controlled experimental conditions. The evidence does not establish statistical equivalence, interchangeability of protocol classes, or clinical safety near critical anatomy. Validation in living patients is needed before broad implementation.

  • Open Access

    Insertion Torque Value and Implant Stability Quotient of Bone-Level Versus Tissue-Level Dental Implants: A Pilot Randomized Clinical Trial

    by Ahmed Samir Elkattan, Mónica Blázquez-Hinarejos, Hassan Ahmed Assiri, Sonia Egido-Moreno, Francisco Javier Parra-Moreno, Eva Otero-Rey, Xavier Roselló-Llabrés, José López-López

    This randomized clinical trial aimed to assess the relation of insertion torque value (ITV) and implant stability quotient (ISQ) between bone-level (BL) and tissue-level (TL) dental implants (ISQ recorded immediately and 3 months after implant placement). A total of 90 dental implants (44 BL, 46 TL; BioHorizons Camlog, Iberica) were placed in 21 patients. ITV was recorded at placement. ISQ (Penguin device, Klockner) was measured horizontally (ISQ-H) and vertically (ISQ-V) at baseline and at the 90-day follow-up. The Mann–Whitney U test and Spearman's correlation tests (α = 0.05) were used for the analyses. No significant difference in ITV was found between the BL (36.0 ± 11.5 Ncm) and TL (38.0 ± 11.5 Ncm) groups (p = 0.381). Similarly, no significant differences were observed in baseline ISQ-H (p = 0.928) or ISQ-V (p = 0.874). At 90 days, ISQ-H values were marginally higher in the TL group (66.5 ± 20.9) compared to the BL group (57.1 ± 18.9; p = 0.029). A significant positive correlation was found between ITV and baseline ISQ (r = 0.493, p < 0.001), but not with 90-day ISQ values. Implant design (BL vs. TL) did not significantly influence ITV or ISQ. The finding of greater horizontal stability for TL implants at 90 days, while marginal, suggests a potential long-term biomechanical difference warranting further study. The dissociation between insertion torque and 90-day stability indicates that secondary stability is governed by factors beyond initial mechanical engagement.

  • Open Access

    Marginal Bone Loss Around Bone-Level and Tissue-Level Implants: A Systematic Review and Meta-Analysis

    by Ahmed Elkattan, Natalia Torres-Velázquez, Mónica Blázquez-Hinarejos, Sonia Egido-Moreno, Raúl Ayuso-Montero, Xavier Roselló-Llabrés, José López-López

    Purpose: To conduct a comprehensive systematic review and meta-analysis on marginal bone loss (MBL) in dental implants, enhancing the understanding and management of both bone-level and tissue-level implants. Methods: MEDLINE-PubMed and Scopus databases were searched for relevant English articles (up to April 2024), assessing the MBL as the primary outcome. The relevant data were extracted, and a meta-analysis was performed to evaluate the effect of implant neck design. Results: A total of 17 studies were included for qualitative analysis. Out of the 21 articles included, 15 studies established a statistically significant difference in MBL between the study groups; however, the differences were not found to be clinically relevant. Bone-level implants with platform-switched abutments in most of the cases showed better marginal bone stability compared to tissue-level implants or bone-level implants with matching abutments. Seven RCT studies were evaluated for the MBL between bone-level and tissue-level implants. The difference in MBL between bone-level implants and tissue-level implants was statistically significant, with a greater loss of bone in bone-level implants (Mean Difference: 0.11, 95% CI:0.02 to 0.19, p = 0.01 and I2 heterogeneity: 81%, p < 0.0001). Conclusions: This review underscores the need for standardized measurement techniques, consideration of patient-specific factors in clinical decision-making, and further long-term studies to optimize dental implant success and patient outcomes.


  • Open Access

    PAIN, OEDEMA AND TRISMUS RESPONSES FOLLOWING PHOTOBIOMODULATION THERAPY IMMEDIATELY AFTER LOWER THIRD MOLAR EXTRACTION: RESULTS OF A RANDOMIZED, DOBLE-BLIND AND SPLIT MOUTH CLINICAL TRIAL

    by Gisela Cristina Vianna Camolesi, Ahmed Samir EL Kattan, José Lopez-Lopez, Andrés Blanco-Carrión, Abel García-García, Pilar Gándara-Vila, Mario Pérez-Sayáns