QXQiang Xu

Qiang Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qiang Xu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Entropy production analysis of interfacial hydrodynamic instability and gas-pocket evolution in a centrifugal pump

    by Xiaoyu Dai, Qimeng Liu, Qiang Xu, Liejin Guo

    Gas–liquid two-phase flows in centrifugal pumps exhibit severe performance degradation driven by complex interactions among centrifugal forces, adverse pressure gradients, and dynamically evolving interfacial instabilities. This study establishes a generalized entropy production (EP) framework within the Eulerian–Eulerian paradigm to systematically quantify the irreversible energy dissipation mechanisms in a multistage centrifugal pump operating under both single-phase and gas–liquid two-phase conditions. Baseline single-phase analysis reveals that turbulent dissipation (TD), driven by intense shear-layer interactions, dominates EP in the diffuser, whereas viscous dissipation (VD) governs the loss within the impeller. For gas–liquid flows, a generalized theoretical expression for EP that explicitly accounts for interphase momentum exchange, interfacial viscous drag, and turbulent fluctuations of the continuous phase is formulated. The analysis uncovers a critical, previously overlooked loss mechanism: the interfacial VD is strongly coupled with gas-pocket instability at the impeller shroud. Furthermore, as the inlet gas volume fraction increases from 2% to 15%, the dominant dissipative regions undergo a spatial migration from the shroud-side outlet toward the hub-side inlet. Despite the significance of interfacial effects, the TD of the continuous liquid phase remains the paramount contributor to overall EP. These insights advance the thermodynamic understanding of energy degradation in multiphase rotating machinery, providing a theoretical baseline for the hydrodynamic optimization of gas-handling centrifugal pumps.

  • Dynamics of hydrogen bubble movement and oscillation on platinum microelectrodes during water electrolysis

    by Zeyuan Duan, Xuanxiang Zhao, Jinfeng Li, Yonglu She, Liejin Guo, Qiang Xu

    Insight into the evolution and movement of bubbles during water electrolysis is crucial to promoting bubble detachment. Here, we investigate the dynamics of hydrogen bubble oscillation on a platinum microelectrode by varying electrolyte species and concentration. The electrolyte series favorable for bubble oscillation is identified as H2SO4 > HCl ≈ HNO3 > HClO4. This series exhibits different bubble evolution modes, from bubble oscillation in sulfuric acid to monotonous growth in perchloric acid. Using the positive feedback relationship between displacement and current, differential equations for bubble motion are established, accurately predicting experimental bubble displacement and oscillation. In the growth controlled by the electrochemical reaction rate, buoyancy drives a linear increase in the oscillation equilibrium position over time. The exponential increase in amplitude arises from the negative damping mechanism induced by the bubble motion and reaction rate. The critical period for bubble oscillation is determined, enabling quantification of the oscillation propensity.


  • Dynamic evolution of the gas–liquid interface and gas blockage mechanism in rotating channels of a multistage electric submersible pump

    by Xiaoyu Dai, Qiang Xu, Chenyu Yang, Xiaobin Su, Liejin Guo

    Under high gas volume fraction conditions, gas blockage in the rotating channel of electric submersible pumps (ESPs) can lead to severe performance deterioration or even failure. This paper presents a numerical study focusing on the dynamic evolution of the gas–liquid interface and the gas blockage mechanism in a rotating channel, mimicking the internal flow of an ESP. A computational fluid dynamics method coupling the population balance model and the ideal gas model is employed. Compared to previous studies, the average error of the simulations with experimental results in this research has been reduced from 25.6% to 8.2%. Based on this, this paper deeply explores the regulatory effects of the operating parameters of a three-stage ESP on the two-phase flow structure and the gas phase distribution characteristics. The results show that increasing the inlet gas volume fraction enhances backflow at the impeller outlet, widening the gas–liquid velocity gap. Gas buildup in the impeller–diffuser transition zone blocks the flow, sharply raising resistance and reducing stability. This paper further studies the distribution law of bubble sizes within the three sets of impellers and establishes and verifies an equivalent bubble size prediction model suitable for different stage impellers.


  • Effect of laser spot diameter on mass transfer mechanisms in photoelectrochemical water splitting

    by Jiayang Chi, Leqing Tao, Qiang Xu, Fanyu Tang, Liejin Guo

    Clarifying the mass transfer mechanism in the evolution of bubbles on the surface of photoelectrodes can help break the shackles that limit the efficiency of photoelectrochemical water splitting. This paper utilized an electrochemical workstation and a high-speed camera to synchronously record the evolution of oxygen bubbles on the surface of thin-film catalysts and their electrochemical signals. The nucleation and detachment characteristics of bubbles at different spot diameters were investigated, and the gas evolution efficiency and mass transfer coefficient were calculated. As the spot diameter increases, the nucleation potential, terminal rising velocity, and growth duration of the bubbles show an increasing trend, and the increase in the gas evolution efficiency reflects an increase in the proportion of gas molecules entering the bubbles. According to the calculations using the mass transfer model, the mass transfer coefficient decreases as the spot diameter increases. The mass transfer coefficient increased by a factor of 1.46 when the spot diameter decreased from 1176 to 700 μm. Our study showed that reducing the spot diameter can effectively improve the mass transfer of gaseous products on the photoelectrode surface and facilitate the nucleation and rapid detachment of bubbles.

  • Pressure drop of slug flow in horizontal pipes with different pipe diameters and liquid viscosities

    by Yeqi Cao, Qiang Xu, Haiyang Yu, Yuwen Li, Bo Huang, Liejin Guo

    Accurate prediction of the horizontal slug pressure drop is valuable for optimizing the multiphase pipeline transport process and ensuring the stable operation of the pipeline systems and treatment facilities. Experimental slug pressure drop research is conducted based on differential pressure signals in the short (0.065 m ID, 215D) and long (0.046 m ID, 35 957D) horizontal pipes. A slug pressure drop database in horizontal pipes is constructed over a wider range of pipe diameters (0.030–0.3 m), liquid viscosities (0.0101–6.25 Pa⋅s), and pipe lengths (6–1657 m). The slug pressure drop increases with decreasing pipe diameter, while the distribution range of slug pressure drop vs the superficial gas velocity rises with increasing liquid viscosity. The 26 pressure drop prediction models are evaluated for their ability in the horizontal slug pressure drop database with different pipe structures and fluid properties, and the best pressure drop correlations are selected for the low, medium, and high liquid viscosity ranges. Accordingly, a combined pressure drop prediction approach of horizontal slug flow based on liquid viscosity classification is proposed with a Pearson's correlation coefficient of 0.987, and the average absolute percentage error is reduced from 44.98% to 30.14%. Based on the Lockhart–Martinelli method, a prediction correlation for horizontal slug pressure drop is developed over a wider range of pipe diameters and liquid viscosities, and industrial near-horizontal pressure drop data are successfully predicted with 89.6% of the data in the error interval of ±20%.