Agnes C. Gläsel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Agnes C. Gläsel has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Alexander Pankraz
Biocontrol, Bioscientia Healthcare GmbH Ingelheim Germany
1 shared publicationAlina Langenhagen
Freie Universität Berlin
1 shared publication- Andreas Maier
Friedrich-Alexander-Universität Erlangen-Nürnberg
1 shared publication Anne Katherine Jasensky
Laboklin GmbH und Co. KG
1 shared publicationAnne Petrick
Freie Universität Berlin
1 shared publication- Christian Marzahl
Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU)
1 shared publication
Latest Publications
- Open Access
- 10 February 2025
- Published by Wiley in Veterinary Clinical Pathology
- Vol. 54 (1) , 43-52
Evaluation of the analytical performance of a point‐of‐care analyzer for the measurement of feline serum thyroxine concentration in comparison with a chemiluminescence enzyme immunoassay
Background: Total thyroxine (TT4) measurement is used to assess thyroid status in cats.Objectives: The aim of the prospective study was to evaluate the analytical performance of the point‐of‐care analyzer (POCA) Immuno AU10V using the v‐T4 test kit for feline TT4 measurement. Additionally, method comparison with a benchtop analyzer (IMMULITE 2000) was done.Methods: Validation included linearity, inter‐ and intra‐assay precision, precision near the lower limit of quantification (LloQ), and interference testing for hemoglobin, lipid, and bilirubin. Correlation and bias were assessed.Results: Linearity was given within the dynamic range. Coefficients of variation (CV) were ≤4% near the LloQ as well as for intra‐and inter‐assay precision. No interference was observed for lipid and bilirubin, while hemoglobin caused a negative bias of 28%. Method comparison included 74 samples within three TT4 concentration ranges (0.5–3.7, >3.7–5.13, >5.13–8 μg/dL). Correlation between POCA and reference method was excellent (rs = 0.95) with a slight proportional bias of 4.5%. TEobs was between 7.0% and 9.8%. Despite substantial agreement, discordant results on thyroid status occurred in 15% of samples.Conclusions: The analytical performance of the POCA was excellent, as was its correlation with the reference method. Except for the interferent effect of hemoglobin, the TEobs was 8 μg/dL, and de novo reference intervals need to be established.
- 10 February 2025
- Published by Wiley in Veterinary Clinical Pathology
- Vol. 54 (1) , 43-52
Open AccessEvaluation of the analytical performance of a point‐of‐care analyzer for the measurement of feline serum thyroxine concentration in comparison with a chemiluminescence enzyme immunoassay
Background: Total thyroxine (TT4) measurement is used to assess thyroid status in cats.Objectives: The aim of the prospective study was to evaluate the analytical performance of the point‐of‐care analyzer (POCA) Immuno AU10V using the v‐T4 test kit for feline TT4 measurement. Additionally, method comparison with a benchtop analyzer (IMMULITE 2000) was done.Methods: Validation included linearity, inter‐ and intra‐assay precision, precision near the lower limit of quantification (LloQ), and interference testing for hemoglobin, lipid, and bilirubin. Correlation and bias were assessed.Results: Linearity was given within the dynamic range. Coefficients of variation (CV) were ≤4% near the LloQ as well as for intra‐and inter‐assay precision. No interference was observed for lipid and bilirubin, while hemoglobin caused a negative bias of 28%. Method comparison included 74 samples within three TT4 concentration ranges (0.5–3.7, >3.7–5.13, >5.13–8 μg/dL). Correlation between POCA and reference method was excellent (rs = 0.95) with a slight proportional bias of 4.5%. TEobs was between 7.0% and 9.8%. Despite substantial agreement, discordant results on thyroid status occurred in 15% of samples.Conclusions: The analytical performance of the POCA was excellent, as was its correlation with the reference method. Except for the interferent effect of hemoglobin, the TEobs was 8 μg/dL, and de novo reference intervals need to be established.
- Open Access
- 27 February 2021
- Published by Springer Nature
- p. 296
Abstract: Are Fast Labeling Methods Reliable?
- 27 February 2021
- Published by Springer Nature
- p. 296
Open AccessAbstract: Are Fast Labeling Methods Reliable?