Uppuluri Suryavalli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Uppuluri Suryavalli has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Sadhu Radha Krishna
JNTUA College of Engineering Pulivendula
2 shared publications - Shaik Hussain Vali
JNTUA College of Engineering Pulivendula
2 shared publications - V. S. S. Pavan Kumar Hari
Department of Energy Science and Engineering, Indian Institute of Technology Bombay, Mumbai, India
2 shared publications - Vempalle Rafi
JNTUA College of Engineering Pulivendula
2 shared publications - Murkur Rajesh
JNTUA College of Engineering Pulivendula
1 shared publication - Pradyumna Kumar Dhal
Vel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 15 (2) , 600-609
Hourly scheduling of thermal units utilizing an innovative hybrid approach
The producing unit must be turned on at a time that meets the power system network's needs. It also determines the order of unit shutdowns based on cost. Unit commitment includes computation and turning units on and off. Committed units are planned to join the power system network. The combinatorial character of unit commitment makes it a crucial research issue and optimization job in contemporary power system. In order to effectively use the available resources and equalize the load demand on an hourly basis, unit commitment might be used. In order to solve an optimization issue involving unit commitment, this work introduces a new hybrid approach that combines a whale optimization algorithm (WOA) with a self-organizing migration algorithm (SOMA). An important part of any migration loop is the WOA technique, which is used to evaluate the optimum strength population from the populations that are created stochastically. The suggested hybrid approach is evaluated using two test systems. Before moving on to the IEEE 39 bus system, a four-unit system is implemented. The efficiency of the suggested hybrid WAOSOMA is addressed by comparing the generated simulation results with approaches found in the literature.
- 1 June 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 15 (2) , 600-609
Open AccessHourly scheduling of thermal units utilizing an innovative hybrid approach
The producing unit must be turned on at a time that meets the power system network's needs. It also determines the order of unit shutdowns based on cost. Unit commitment includes computation and turning units on and off. Committed units are planned to join the power system network. The combinatorial character of unit commitment makes it a crucial research issue and optimization job in contemporary power system. In order to effectively use the available resources and equalize the load demand on an hourly basis, unit commitment might be used. In order to solve an optimization issue involving unit commitment, this work introduces a new hybrid approach that combines a whale optimization algorithm (WOA) with a self-organizing migration algorithm (SOMA). An important part of any migration loop is the WOA technique, which is used to evaluate the optimum strength population from the populations that are created stochastically. The suggested hybrid approach is evaluated using two test systems. Before moving on to the IEEE 39 bus system, a four-unit system is implemented. The efficiency of the suggested hybrid WAOSOMA is addressed by comparing the generated simulation results with approaches found in the literature.
- Open Access
- 1 September 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 14 (3) , 701-711
Enhanced multi-mode control of Z-source virtual synchronous generator for photovoltaic systems using fuzzy logic controller
An enhanced multi-mode control solution for a Z-source virtual synchronous generator (ZVSG) that makes use of a fuzzy logic controller (FLC) is proposed by this study for use in photovoltaic (PV) systems. As a potential grid integration option for PV systems, the ZVSG has great potential due to its steady and adjustable power production. A stable voltage and frequency output can be maintained by the ZVSG when it is running in a variety of modes, such as grid-connected, standalone, and islanding, according to the control approach that has been provided. The FLC is used for the purpose of controlling the switching frequency of the ZVSG as well as the DC-link voltage. The performance of the ZVSG is improved by the FLC-based control approach that has been proposed. This technique reduces the steady state error and offers a rapid dynamic response. The results of the simulation show that the recommendation for a control approach improves the performance of the ZVSG across a wide variety of operating modes and load conditions.
- 1 September 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 14 (3) , 701-711
Open AccessEnhanced multi-mode control of Z-source virtual synchronous generator for photovoltaic systems using fuzzy logic controller
An enhanced multi-mode control solution for a Z-source virtual synchronous generator (ZVSG) that makes use of a fuzzy logic controller (FLC) is proposed by this study for use in photovoltaic (PV) systems. As a potential grid integration option for PV systems, the ZVSG has great potential due to its steady and adjustable power production. A stable voltage and frequency output can be maintained by the ZVSG when it is running in a variety of modes, such as grid-connected, standalone, and islanding, according to the control approach that has been provided. The FLC is used for the purpose of controlling the switching frequency of the ZVSG as well as the DC-link voltage. The performance of the ZVSG is improved by the FLC-based control approach that has been proposed. This technique reduces the steady state error and offers a rapid dynamic response. The results of the simulation show that the recommendation for a control approach improves the performance of the ZVSG across a wide variety of operating modes and load conditions.
- 17 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (9) , 8778-8788
Influence of Sampling Method and Frequency Ratio on PWM Voltage Harmonics in Two-Level Voltage Source Inverters
Analytical evaluation of harmonic spectra of pulse-width-modulated voltages in power electronic converters is a useful tool for practicing engineers. An analytical method which helps in understanding the underlying implications of sampling technique and frequency ratio on harmonic spectrum of PWM voltage is presented. It leads to the derivation of simple and accurate closed-form expressions for Fourier coefficients of output voltage in single-phase and three-phase two-level voltage source inverters (VSI) operated with regularly-sampled sine-triangle pulse width modulation (STPWM). The expressions are derived for both symmetric and asymmetric regular sampling techniques of STPWM. The proposed analytical expressions facilitate the estimation of voltage harmonic spectrum for given dc bus voltage, modulation index and carrier-to-fundamental frequency ratio. This article also presents the effect of frequency ratio on sampled modulating signal and proposes a method to estimate the voltage harmonic spectrum in the case of frequency ratio being a noninteger, which increases its practical utility. Simulation and experimental results under a wide range of operating conditions are presented to validate the analytically evaluated voltage harmonic spectra.
- 17 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (9) , 8778-8788
Influence of Sampling Method and Frequency Ratio on PWM Voltage Harmonics in Two-Level Voltage Source Inverters
Analytical evaluation of harmonic spectra of pulse-width-modulated voltages in power electronic converters is a useful tool for practicing engineers. An analytical method which helps in understanding the underlying implications of sampling technique and frequency ratio on harmonic spectrum of PWM voltage is presented. It leads to the derivation of simple and accurate closed-form expressions for Fourier coefficients of output voltage in single-phase and three-phase two-level voltage source inverters (VSI) operated with regularly-sampled sine-triangle pulse width modulation (STPWM). The expressions are derived for both symmetric and asymmetric regular sampling techniques of STPWM. The proposed analytical expressions facilitate the estimation of voltage harmonic spectrum for given dc bus voltage, modulation index and carrier-to-fundamental frequency ratio. This article also presents the effect of frequency ratio on sampled modulating signal and proposes a method to estimate the voltage harmonic spectrum in the case of frequency ratio being a noninteger, which increases its practical utility. Simulation and experimental results under a wide range of operating conditions are presented to validate the analytically evaluated voltage harmonic spectra.