Thilini Savindya Karunarathna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thilini Savindya Karunarathna has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Zilu Liang
Ubiquitous and Personal Computing Lab, Kyoto University of Advanced Science (KUAS), Kyoto, Japan
2 shared publications - Andrew Beten
College of Arts and Science, Ohio State University, Columbus, OH 43210, USA
1 shared publication - Ayaan Baig
College of Arts and Science, Ohio State University, Columbus, OH 43210, USA
1 shared publication - Luna Lococco
College of Arts and Science, Ohio State University, Columbus, OH 43210, USA
1 shared publication
Latest Publications
- Open Access
- 7 November 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 118 (1) , 88
Systematic Analysis of Distribution Shifts in Cross-Subject Glucose Prediction Using Wearable Physiological Data
Wearable sensors offer a promising platform for non-invasive glucose monitoring by indirectly predicting glucose levels from physiological signals. However, machine learning models trained on such data often suffer degraded performance when applied to new individuals due to distribution shifts in physiological patterns. This study investigates how inter-subject distribution shifts impact the performance of glucose prediction models trained on wearable data. We utilized the BIGIDEAs dataset, which includes simultaneous recordings of glucose levels and multimodal physiological signals. Personalized XGBoost regression models were trained on data from 10 subjects and evaluated on 5 held-out subjects to assess cross-subject generalization. Distribution shifts in glucose profiles between training and test subjects were quantified using the Anderson–Darling (AD) statistic. The results showed that models trained on one individual performed poorly when tested on others. Repeated measures correlation analysis revealed significant positive correlations between the AD statistic and model performance metrics, including RMSE, NRMSE, and MARD. Our findings highlight the challenge of inter-individual generalization and the need for distribution-aware models. We propose personalized calibration and subject phenotyping as future directions to enhance model generalizability.
- 7 November 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 118 (1) , 88
Open AccessSystematic Analysis of Distribution Shifts in Cross-Subject Glucose Prediction Using Wearable Physiological Data
Wearable sensors offer a promising platform for non-invasive glucose monitoring by indirectly predicting glucose levels from physiological signals. However, machine learning models trained on such data often suffer degraded performance when applied to new individuals due to distribution shifts in physiological patterns. This study investigates how inter-subject distribution shifts impact the performance of glucose prediction models trained on wearable data. We utilized the BIGIDEAs dataset, which includes simultaneous recordings of glucose levels and multimodal physiological signals. Personalized XGBoost regression models were trained on data from 10 subjects and evaluated on 5 held-out subjects to assess cross-subject generalization. Distribution shifts in glucose profiles between training and test subjects were quantified using the Anderson–Darling (AD) statistic. The results showed that models trained on one individual performed poorly when tested on others. Repeated measures correlation analysis revealed significant positive correlations between the AD statistic and model performance metrics, including RMSE, NRMSE, and MARD. Our findings highlight the challenge of inter-individual generalization and the need for distribution-aware models. We propose personalized calibration and subject phenotyping as future directions to enhance model generalizability.
- Open Access
Development of Non-Invasive Continuous Glucose Prediction Models Using Multi-Modal Wearable Sensors in Free-Living Conditions
Continuous monitoring of glucose levels is important for diabetes management and prevention. While traditional glucose monitoring methods are often invasive and expensive, recent approaches using machine learning (ML) models have explored non-invasive alternatives—but many still depend on manually logged food intake and activity, which is burdensome and impractical for everyday use. In this study, we propose a novel approach that eliminates the need for manual input by utilizing only passively collected, automatically recorded multi-modal data from non-invasive wearable sensors. This enables practical and continuous glucose prediction in real-world, free-living environments. We used the BIG IDEAs Lab Glycemic Variability and Wearable Device Data (BIGIDEAs) dataset, which includes approximately 26,000 CGM readings, simultaneous ly collected wearable data, and demographic information. A total of 236 features encompassing physiological, behavioral, circadian, and demographic factors were constructed. Feature selection was conducted using random-forest-based importance analysis to select the most relevant features for model training. We evaluated the effectiveness of various ML regression techniques, including linear regression, ridge regression, random forest regression, and XGBoost regression, in terms of prediction and clinical accuracy. Biological sex, circadian rhythm, behavioral features, and tonic features of electrodermal activity (EDA) emerged as key predictors of glucose levels. Tree-based models outperformed linear models in both prediction and clinical accuracy. The XGBoost (XR) model performed best, achieving an R-squared of 0.73, an RMSE of 11.9 mg/dL, an NRMSE of 0.52 mg/dL, a MARD of 7.1%, and 99.4% of predictions falling within Zones A and B of the Clarke Error Grid. This study demonstrates the potential of combining feature engineering and tree-based ML regression techniques for continuous glucose monitoring using wearable sensors.
Open AccessDevelopment of Non-Invasive Continuous Glucose Prediction Models Using Multi-Modal Wearable Sensors in Free-Living Conditions
Continuous monitoring of glucose levels is important for diabetes management and prevention. While traditional glucose monitoring methods are often invasive and expensive, recent approaches using machine learning (ML) models have explored non-invasive alternatives—but many still depend on manually logged food intake and activity, which is burdensome and impractical for everyday use. In this study, we propose a novel approach that eliminates the need for manual input by utilizing only passively collected, automatically recorded multi-modal data from non-invasive wearable sensors. This enables practical and continuous glucose prediction in real-world, free-living environments. We used the BIG IDEAs Lab Glycemic Variability and Wearable Device Data (BIGIDEAs) dataset, which includes approximately 26,000 CGM readings, simultaneous ly collected wearable data, and demographic information. A total of 236 features encompassing physiological, behavioral, circadian, and demographic factors were constructed. Feature selection was conducted using random-forest-based importance analysis to select the most relevant features for model training. We evaluated the effectiveness of various ML regression techniques, including linear regression, ridge regression, random forest regression, and XGBoost regression, in terms of prediction and clinical accuracy. Biological sex, circadian rhythm, behavioral features, and tonic features of electrodermal activity (EDA) emerged as key predictors of glucose levels. Tree-based models outperformed linear models in both prediction and clinical accuracy. The XGBoost (XR) model performed best, achieving an R-squared of 0.73, an RMSE of 11.9 mg/dL, an NRMSE of 0.52 mg/dL, a MARD of 7.1%, and 99.4% of predictions falling within Zones A and B of the Clarke Error Grid. This study demonstrates the potential of combining feature engineering and tree-based ML regression techniques for continuous glucose monitoring using wearable sensors.
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Physiological Signal Based Blood Glucose Prediction in Diabetics and Non-Diabetics
Effective blood glucose regulation is essential for both diabetic and non-diabetic individuals. Finger-prick methods are inconvenient and painful, while continuous glucose monitoring (CGM) systems are costly and require frequent sensor replacements. This paper proposes an innovative approach for continuous real-time blood glucose level estimation using non-invasive physiological signals and ensemble regression techniques. We observed significant differences in the predictive power of individual features and overall model performance between the diabetic and the non-diabetic groups. The best model for the diabetic group achieved better performance (R2 = 0.50) compared to the best model for the non-diabetic group (R2 = 0.27). However, when evaluated for clinical accuracy, the non-diabetic models outperformed the diabetic models. The best non -diabetic model had 100% of predictions in the clinically acceptable zones of the Clarke Error Grids (CEG), while the best diabetic model had only 91%. The between-group differences in model performance are likely due to the variations in underlying glucose dynamics between diabetic and non-diabetic individuals. Our findings highlight the necessity of collecting and sharing large multimodal datasets from both diabetic and non-diabetic populations, as well as evaluating glucose prediction models from both mathematical and clinical accuracy.
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Physiological Signal Based Blood Glucose Prediction in Diabetics and Non-Diabetics
Effective blood glucose regulation is essential for both diabetic and non-diabetic individuals. Finger-prick methods are inconvenient and painful, while continuous glucose monitoring (CGM) systems are costly and require frequent sensor replacements. This paper proposes an innovative approach for continuous real-time blood glucose level estimation using non-invasive physiological signals and ensemble regression techniques. We observed significant differences in the predictive power of individual features and overall model performance between the diabetic and the non-diabetic groups. The best model for the diabetic group achieved better performance (R2 = 0.50) compared to the best model for the non-diabetic group (R2 = 0.27). However, when evaluated for clinical accuracy, the non-diabetic models outperformed the diabetic models. The best non -diabetic model had 100% of predictions in the clinically acceptable zones of the Clarke Error Grids (CEG), while the best diabetic model had only 91%. The between-group differences in model performance are likely due to the variations in underlying glucose dynamics between diabetic and non-diabetic individuals. Our findings highlight the necessity of collecting and sharing large multimodal datasets from both diabetic and non-diabetic populations, as well as evaluating glucose prediction models from both mathematical and clinical accuracy.