Vithit Pungkun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vithit Pungkun has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Chayanit Jumpee
Department of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand
1 shared publication - Krisanat Chuamsaamarkkee
Faculty of Medicine Ramathibodi Hospital Department of Diagnostic and Therapeutic Radiology Division of Nuclear Medicine Mahidol University Thailand Bangkok
1 shared publication - Pakjira Morhrasi
Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
1 shared publication - Panatsada Awikunprasert
Department of Radiological Technology, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
1 shared publication - Panuwat Pattum
Department of Radiology, Faculty of Medicine Khon Kaen University Khon Kaen Thailand
1 shared publication - Phiphat Phruksarojanakun
Office of Atoms for Peace, Bangkok, Thailand
1 shared publication
Latest Publications
- 2 May 2025
- Published by Chiang Mai University in Journal of Associated Medical Sciences
- Vol. 58 (2) , 148-160
Radiation safety assessment of patient and staff during intracranial aneurysm treatment: A phantom study
Background: Endovascular treatment using coiling embolization for intracranial aneurysms is common in interventional neuroradiology (INR). However, it is associated with high radiation exposure to both patients and medical staff. The assessment and management of radiation risk have been a concern. Objective: To evaluate patient and scatter radiation doses at INR staff working position during the coiling embolization procedure in a phantom study. Materials and methods: An anthropometric phantom from head to pelvis was placed on an angiographic table. To determine the phantom’s entrance skin dose (ESD), 19 NanoDot optically stimulated luminescence dosimeters (OSLDs) were placed on the surface of the head phantom. Moreover, 6 NanoDot OSLDs were also placed on the surface of the phantom at 3 critical organs (eyes, thyroid, ovaries). To determine the scatter radiation dose at staff working position, polyvinyl chloride pipes (150 cm height) were placed at the position of all staff, including interventional radiologist (IR), radiology resident (RR), scrubbed nurse (SN), radiologic technologist (RT), circulating nurse (CN), and nurse anesthetists (AN). The InLight® OSLDs were placed on each PVC pipe at 50, 100, and 150 cm height from the floor level. Coiling embolization was simulated following the standard procedure using a bi-plane digital subtraction angiography unit with standard radiation protective equipment. The patient doses from the radiation dose structured report (RDSR) were also recorded. Results: The highest ESDs were observed in the occipital part (1,631.56±36.97 mGy). These ESD peaks were also observed within the safety limit and produced no skin reaction. The radiation dose at the left eye was observed to be the highest value among critical organs. The highest scatter radiation dose was observed at the position of IR at 100 cm level. Among CN, AN, and RT positions, the highest dose was recorded at the RT position at the level of 150 cm. The RDSR showed that most of the patient radiation dose was received from the 2-dimension angiography. Conclusion: The distribution of radiation dose varied across different staff positions. As the key person conducting the coiling embolization procedure, the IR position received the highest radiation dose. Thus, close monitoring and development of additional radiation protection methods for this position are essential. Although the radiation dose at the back of the head was elevated, it remained within safety limits. Nevertheless, the monitoring of potential radiation effects should not be neglected.
- 2 May 2025
- Published by Chiang Mai University in Journal of Associated Medical Sciences
- Vol. 58 (2) , 148-160
Radiation safety assessment of patient and staff during intracranial aneurysm treatment: A phantom study
Background: Endovascular treatment using coiling embolization for intracranial aneurysms is common in interventional neuroradiology (INR). However, it is associated with high radiation exposure to both patients and medical staff. The assessment and management of radiation risk have been a concern. Objective: To evaluate patient and scatter radiation doses at INR staff working position during the coiling embolization procedure in a phantom study. Materials and methods: An anthropometric phantom from head to pelvis was placed on an angiographic table. To determine the phantom’s entrance skin dose (ESD), 19 NanoDot optically stimulated luminescence dosimeters (OSLDs) were placed on the surface of the head phantom. Moreover, 6 NanoDot OSLDs were also placed on the surface of the phantom at 3 critical organs (eyes, thyroid, ovaries). To determine the scatter radiation dose at staff working position, polyvinyl chloride pipes (150 cm height) were placed at the position of all staff, including interventional radiologist (IR), radiology resident (RR), scrubbed nurse (SN), radiologic technologist (RT), circulating nurse (CN), and nurse anesthetists (AN). The InLight® OSLDs were placed on each PVC pipe at 50, 100, and 150 cm height from the floor level. Coiling embolization was simulated following the standard procedure using a bi-plane digital subtraction angiography unit with standard radiation protective equipment. The patient doses from the radiation dose structured report (RDSR) were also recorded. Results: The highest ESDs were observed in the occipital part (1,631.56±36.97 mGy). These ESD peaks were also observed within the safety limit and produced no skin reaction. The radiation dose at the left eye was observed to be the highest value among critical organs. The highest scatter radiation dose was observed at the position of IR at 100 cm level. Among CN, AN, and RT positions, the highest dose was recorded at the RT position at the level of 150 cm. The RDSR showed that most of the patient radiation dose was received from the 2-dimension angiography. Conclusion: The distribution of radiation dose varied across different staff positions. As the key person conducting the coiling embolization procedure, the IR position received the highest radiation dose. Thus, close monitoring and development of additional radiation protection methods for this position are essential. Although the radiation dose at the back of the head was elevated, it remained within safety limits. Nevertheless, the monitoring of potential radiation effects should not be neglected.
- Open Access
- 1 January 2025
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 40 (4) , 303-311
Monte Carlo simulation of eye lens dose and shielding effectiveness for radiation workers in nuclear medicine
The aim of this work was to estimate the eye lens dose equivalent at a depth of 3 mm and to evaluate the effectiveness of shielding for radiation workers in nuclear medicine using Monte Carlo simulation with the Monte Carlo N-Particle transport code, version 5. Published air kerma rate constants were used to validate the simulation code for commonly used radionuclides in nuclear medicine, including $ ^{18}\mathrm{F} $, $ ^{99m}\mathrm{Tc} $, and $ ^{131}\mathrm{I} $. Eye lens dose rates with commercially available syringe shields and vial shields were simulated using the Monte Carlo N-Particle code with the Posture, Individual, and Medical Application Laboratory phantom. Shielded and unshielded eye lens dose rates based on commercially available source data were simulated for common radionuclides at various distances. The maximum number of procedures was also estimated based on the eye lens dose limit recommended by the International Commission on Radiological Protection publication 118. The simulated dose rates may be used to evaluate radiation safety considerations for workers in nuclear medicine. Appropriate shielding and eye lens monitoring are particularly recommended for positron-emitting $ ^{18}\mathrm{F} $ and high-activity $ ^{131}\mathrm{I} $ procedures.- 1 January 2025
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 40 (4) , 303-311
Open AccessMonte Carlo simulation of eye lens dose and shielding effectiveness for radiation workers in nuclear medicine
The aim of this work was to estimate the eye lens dose equivalent at a depth of 3 mm and to evaluate the effectiveness of shielding for radiation workers in nuclear medicine using Monte Carlo simulation with the Monte Carlo N-Particle transport code, version 5. Published air kerma rate constants were used to validate the simulation code for commonly used radionuclides in nuclear medicine, including $ ^{18}\mathrm{F} $, $ ^{99m}\mathrm{Tc} $, and $ ^{131}\mathrm{I} $. Eye lens dose rates with commercially available syringe shields and vial shields were simulated using the Monte Carlo N-Particle code with the Posture, Individual, and Medical Application Laboratory phantom. Shielded and unshielded eye lens dose rates based on commercially available source data were simulated for common radionuclides at various distances. The maximum number of procedures was also estimated based on the eye lens dose limit recommended by the International Commission on Radiological Protection publication 118. The simulated dose rates may be used to evaluate radiation safety considerations for workers in nuclear medicine. Appropriate shielding and eye lens monitoring are particularly recommended for positron-emitting $ ^{18}\mathrm{F} $ and high-activity $ ^{131}\mathrm{I} $ procedures.