Jiatai Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiatai Gao has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Xichen Pei
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
5 shared publications - Yu Yang
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
5 shared publications - Zhanlong Zhang
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
5 shared publications - Zijian Dong
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
3 shared publications - Jun Deng
CSG EHV Electric Power Research Institute, Guangzhou, China
2 shared publications - Wenhao He
School of Electrical Engineering, Chongqing University, Chongqing 400044, China
2 shared publications
Latest Publications
- 10 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Measurement of Saturation Characteristic of Transformer Using an Improved AC and DC Voltage Superposition Method
When the transformer is overexcited, deep core saturation sharply increases hysteresis and eddy current losses, while also causing insulation damage and protection device maloperation. Accurately knowing the transformer’s saturation curve is of great significance for modeling its overexcitation characteristics. Based on the linear relationship between the fundamental voltage and the increment of the fundamental current under overexcitation, and the current distortion characteristics, this article proposes an improved method for measuring the transformer’s saturation characteristic curve by superimposing AC and DC voltages. A test device for measuring the saturation characteristic curve of the large-capacity transformer by superimposing AC and DC voltages is developed. The effectiveness of the method is verified by the inrush current test of a single-phase scaled converter transformer under transient overexcitation. The proposed method’s measurement results are highly consistent with the experimental data, and the average error in the inrush current calculated from the measured curve is less than 5%. It can offer valuable support for transformer equivalent modeling, no-load closing inrush current calculation, and inrush current suppression.
- 10 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Measurement of Saturation Characteristic of Transformer Using an Improved AC and DC Voltage Superposition Method
When the transformer is overexcited, deep core saturation sharply increases hysteresis and eddy current losses, while also causing insulation damage and protection device maloperation. Accurately knowing the transformer’s saturation curve is of great significance for modeling its overexcitation characteristics. Based on the linear relationship between the fundamental voltage and the increment of the fundamental current under overexcitation, and the current distortion characteristics, this article proposes an improved method for measuring the transformer’s saturation characteristic curve by superimposing AC and DC voltages. A test device for measuring the saturation characteristic curve of the large-capacity transformer by superimposing AC and DC voltages is developed. The effectiveness of the method is verified by the inrush current test of a single-phase scaled converter transformer under transient overexcitation. The proposed method’s measurement results are highly consistent with the experimental data, and the average error in the inrush current calculated from the measured curve is less than 5%. It can offer valuable support for transformer equivalent modeling, no-load closing inrush current calculation, and inrush current suppression.
- Open Access
- 19 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 16
Low-Frequency Transient Model of Single-Phase Four-Limb Converter Transformer Considering the Nonlinear Excitation Characteristics of the Iron Core
Transformer modeling is a crucial method for analyzing transient phenomena such as inrush currents. The primary characteristic of a transformer transient model is its ability to reflect how the transformer’s structure and material properties influence the magnetic and electric fields. In high-voltage direct current (HVDC), the single-phase converter adopts a double-core-limb and double-side-limb configuration, whose core structure, magnetic flux distribution, and ferromagnetic materials differ from conventional power transformers. This paper conducts research on low-frequency transient modeling of single-phase four-limb converter transformers. This study first determines the magnetic field distribution of the single-phase converter transformer with the inclusion of leakage flux. Subsequently, a corresponding model is derived from the principle of duality. Due to the laminated structure, the iron core exhibits different excitation characteristics from those of a single silicon steel sheet. For the excitation branch, AC-DC hybrid excitation is used to measure incremental excitation inductance and the nonlinear excitation curve is calculated based on this inductance. Furthermore, the allocation method of this curve in the core limb, side limb, and yoke is proposed to establish the converter transformer model. The results of no-load and inrush current tests based on the scaled model validate the effectiveness of this model, which can accurately calculate the inrush current under different remanence and closing conditions.
- 19 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 16
Open AccessLow-Frequency Transient Model of Single-Phase Four-Limb Converter Transformer Considering the Nonlinear Excitation Characteristics of the Iron Core
Transformer modeling is a crucial method for analyzing transient phenomena such as inrush currents. The primary characteristic of a transformer transient model is its ability to reflect how the transformer’s structure and material properties influence the magnetic and electric fields. In high-voltage direct current (HVDC), the single-phase converter adopts a double-core-limb and double-side-limb configuration, whose core structure, magnetic flux distribution, and ferromagnetic materials differ from conventional power transformers. This paper conducts research on low-frequency transient modeling of single-phase four-limb converter transformers. This study first determines the magnetic field distribution of the single-phase converter transformer with the inclusion of leakage flux. Subsequently, a corresponding model is derived from the principle of duality. Due to the laminated structure, the iron core exhibits different excitation characteristics from those of a single silicon steel sheet. For the excitation branch, AC-DC hybrid excitation is used to measure incremental excitation inductance and the nonlinear excitation curve is calculated based on this inductance. Furthermore, the allocation method of this curve in the core limb, side limb, and yoke is proposed to establish the converter transformer model. The results of no-load and inrush current tests based on the scaled model validate the effectiveness of this model, which can accurately calculate the inrush current under different remanence and closing conditions.
- 3 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (6) , 3576-3587
A Phase Selection Closing Strategy for LCC-HVDC Converter Transformers Based on the No-Inrush Current Closing Angle Interval
Inrush current generated during the commissioning of converter transformers will seriously threaten the stability of power system. Existing closing strategy cannot suppress inrush current when the AC circuit breaker operation is decentralized and the remanence measurement is inaccurate. This paper first analyzes the magnetic linkage of converter transformers during no-load commissioning, quantifies the suppression effect of pre-insertion resistance on inrush current, and proposes a calculation method of the no-inrush current closing angle interval, which expands the existing research’s no-inrush current closing angle into an interval. Then a phase selection closing strategy for LCC-HVDC converter transformers based on the no-inrush current closing angle interval is proposed. Finally, a simulation model is constructed using PSCAD/EMTDC to verify the proposed method. The results show that inrush current can be effectively suppressed with proposed method under the conditions of ±2 ms deviation in circuit breaker operation and ±1.0 p.u. deviation in residual magnetism flux, demonstrating strong robustness.
- 3 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (6) , 3576-3587
A Phase Selection Closing Strategy for LCC-HVDC Converter Transformers Based on the No-Inrush Current Closing Angle Interval
Inrush current generated during the commissioning of converter transformers will seriously threaten the stability of power system. Existing closing strategy cannot suppress inrush current when the AC circuit breaker operation is decentralized and the remanence measurement is inaccurate. This paper first analyzes the magnetic linkage of converter transformers during no-load commissioning, quantifies the suppression effect of pre-insertion resistance on inrush current, and proposes a calculation method of the no-inrush current closing angle interval, which expands the existing research’s no-inrush current closing angle into an interval. Then a phase selection closing strategy for LCC-HVDC converter transformers based on the no-inrush current closing angle interval is proposed. Finally, a simulation model is constructed using PSCAD/EMTDC to verify the proposed method. The results show that inrush current can be effectively suppressed with proposed method under the conditions of ±2 ms deviation in circuit breaker operation and ±1.0 p.u. deviation in residual magnetism flux, demonstrating strong robustness.
- Open Access
- 12 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5375
Research on the Remanence Measurement Method of Transformers Based on the Degaussing Hysteresis Loop
The residual magnetism of the iron core of power transformers can cause an excitation inrush current, posing a threat to the safe and stable operation of the power grid. This paper proposes a transformer remanence measurement method based on a demagnetization hysteresis loop to address the problems of large errors, complex operation, and poor universality in existing remanence measurement methods. This method is designed for off-grid transformers to avoid potential interference to the power grid caused by current pulses during the measurement process. This method constructs an RLC oscillation circuit that utilizes capacitor energy storage and iron core magnetic field energy conversion, combined with the dynamic characteristics of hysteresis loops, to achieve accurate measurement of residual magnetism and synchronous demagnetization. The effectiveness of this method has been verified through residual magnetism measurement experiments on ring transformers and large converter transformers, and it can be applied in specific engineering practice operations. Theoretical analysis shows that the charging range of energy storage capacitors is affected by the hysteresis characteristics of the iron core and the saturation magnetic flux, and the residual magnetization value can be directly calculated based on the difference in the intersection point of the longitudinal axis of the demagnetization hysteresis loop. Simulation and experimental results show that the measurement error of the proposed method is less than 5%—significantly better than traditional methods. This method does not require complex control strategies, has high precision and efficiency, and can provide reliable technical support for residual magnetism detection and suppression of off-grid power transformers.
- 12 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5375
Open AccessResearch on the Remanence Measurement Method of Transformers Based on the Degaussing Hysteresis Loop
The residual magnetism of the iron core of power transformers can cause an excitation inrush current, posing a threat to the safe and stable operation of the power grid. This paper proposes a transformer remanence measurement method based on a demagnetization hysteresis loop to address the problems of large errors, complex operation, and poor universality in existing remanence measurement methods. This method is designed for off-grid transformers to avoid potential interference to the power grid caused by current pulses during the measurement process. This method constructs an RLC oscillation circuit that utilizes capacitor energy storage and iron core magnetic field energy conversion, combined with the dynamic characteristics of hysteresis loops, to achieve accurate measurement of residual magnetism and synchronous demagnetization. The effectiveness of this method has been verified through residual magnetism measurement experiments on ring transformers and large converter transformers, and it can be applied in specific engineering practice operations. Theoretical analysis shows that the charging range of energy storage capacitors is affected by the hysteresis characteristics of the iron core and the saturation magnetic flux, and the residual magnetization value can be directly calculated based on the difference in the intersection point of the longitudinal axis of the demagnetization hysteresis loop. Simulation and experimental results show that the measurement error of the proposed method is less than 5%—significantly better than traditional methods. This method does not require complex control strategies, has high precision and efficiency, and can provide reliable technical support for residual magnetism detection and suppression of off-grid power transformers.
- Open Access
- 19 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (4) , 2235
Risk Assessment Study of Oil Flow Under Inrush Current on the Misoperation of Converter Transformer Gas Relay
In practical engineering, due to the residual magnetism in the iron core of the converter transformer, the inrush current is generated in the case of no-load closing, and the inrush current leads to an oil flow surge inside the converter transformer. Under the influence of oil flow, the gas relay plate will be deflected, and when the deflection angle is too large, the gas relay will malfunction. Because of the lacking research on the influence of the misoperation of the gas relay under the excitation inrush of the converter transformer, it is difficult to effectively suppress the misoperation of gas relay under inrush current. Therefore, the finite element model of the electromagnetic hydraulic coupling of the converter transformer is established in this paper to obtain the oil flow velocity through the gas relay under the inrush current. A fluid–solid coupling model was established inside the gas relay to study the deflection characteristics of the baffle of the gas relay under the inrush current, and the relationship between the inrush current amplitude and the deflection angle of the baffle was mathematically fitted to effectively predict whether the gas relay has the risk of misoperation. From the experimental results, it can be seen that when the amplitude of the inrush current exceeds 6.37 kA, the gas relay will have the risk of misoperation. Finally, the influence of oil flow impact on the gas relay baffle under multiple cycles is considered. The results can provide an effective reference for analyzing the diagnosis of gas relay misoperation under the effect of inrush current.
- 19 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (4) , 2235
Open AccessRisk Assessment Study of Oil Flow Under Inrush Current on the Misoperation of Converter Transformer Gas Relay
In practical engineering, due to the residual magnetism in the iron core of the converter transformer, the inrush current is generated in the case of no-load closing, and the inrush current leads to an oil flow surge inside the converter transformer. Under the influence of oil flow, the gas relay plate will be deflected, and when the deflection angle is too large, the gas relay will malfunction. Because of the lacking research on the influence of the misoperation of the gas relay under the excitation inrush of the converter transformer, it is difficult to effectively suppress the misoperation of gas relay under inrush current. Therefore, the finite element model of the electromagnetic hydraulic coupling of the converter transformer is established in this paper to obtain the oil flow velocity through the gas relay under the inrush current. A fluid–solid coupling model was established inside the gas relay to study the deflection characteristics of the baffle of the gas relay under the inrush current, and the relationship between the inrush current amplitude and the deflection angle of the baffle was mathematically fitted to effectively predict whether the gas relay has the risk of misoperation. From the experimental results, it can be seen that when the amplitude of the inrush current exceeds 6.37 kA, the gas relay will have the risk of misoperation. Finally, the influence of oil flow impact on the gas relay baffle under multiple cycles is considered. The results can provide an effective reference for analyzing the diagnosis of gas relay misoperation under the effect of inrush current.