Alfa Nyandoro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alfa Nyandoro has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Kailas Patil
Vishwakarma University, India
6 shared publications - Prawit Chumchu
Kasetsart University
5 shared publications - Visvanathan Girish R
Vishwakarma University
2 shared publications Deepali Godse
Bharati Vidyapeeth's College of Engineering for Women, Pune, India
1 shared publication- Prawit Chumchu
Kasetsart University
1 shared publication - Sandip Thite
Vishwakarma University, Pune, India
1 shared publication
Latest Publications
- 25 February 2026
- Published by MyJove Corporation
- No. 228,p. e69744
JoVE Video Dataset
Maintaining optimal water quality is essential in aquaculture, particularly for ornamental species such as Kois, where color clarity and environmental balance are directly linked to health and aesthetics. This article presents a complete protocol for designing, deploying, and operating a real-time water quality monitoring system based on underwater image classification using embedded deep learning. The proposed system integrates a low-cost underwater camera with a Raspberry Pi-based controller network in an autonomous water surface robot, enabling the capture, transmission, and classification of aquatic images through a lightweight neural network model. Five water condition categories -- ranging from clear to turbid -- are visually distinguished, with classification accuracy exceeding 99% on a custom dataset. The system is configured to run autonomously, offering continuous assessment and visual alerts for deteriorating conditions. This visual protocol covers device assembly, system calibration, model deployment, and real-time monitoring demonstrations. The method supports sustainable aquaculture practices by enabling non-invasive, continuous evaluation of aquatic environments using affordable, scalable technologies. The approach can be adapted to other aquaculture or environmental monitoring contexts with minimal modification.
- 25 February 2026
- Published by MyJove Corporation
- No. 228,p. e69744
JoVE Video Dataset
Maintaining optimal water quality is essential in aquaculture, particularly for ornamental species such as Kois, where color clarity and environmental balance are directly linked to health and aesthetics. This article presents a complete protocol for designing, deploying, and operating a real-time water quality monitoring system based on underwater image classification using embedded deep learning. The proposed system integrates a low-cost underwater camera with a Raspberry Pi-based controller network in an autonomous water surface robot, enabling the capture, transmission, and classification of aquatic images through a lightweight neural network model. Five water condition categories -- ranging from clear to turbid -- are visually distinguished, with classification accuracy exceeding 99% on a custom dataset. The system is configured to run autonomously, offering continuous assessment and visual alerts for deteriorating conditions. This visual protocol covers device assembly, system calibration, model deployment, and real-time monitoring demonstrations. The method supports sustainable aquaculture practices by enabling non-invasive, continuous evaluation of aquatic environments using affordable, scalable technologies. The approach can be adapted to other aquaculture or environmental monitoring contexts with minimal modification.
- 24 February 2026
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 228,p. e69744
Real-Time Pond Water Assessment via Embedded Deep Learning and Visual Data Acquisition: A Practical Monitoring Approach for Aquaculture
Maintaining optimal water quality is essential in aquaculture, particularly for ornamental species such as Kois, where color clarity and environmental balance are directly linked to health and aesthetics. This article presents a complete protocol for designing, deploying, and operating a real-time water quality monitoring system based on underwater image classification using embedded deep learning. The proposed system integrates a low-cost underwater camera with a Raspberry Pi-based controller network in an autonomous water surface robot, enabling the capture, transmission, and classification of aquatic images through a lightweight neural network model. Five water condition categories -- ranging from clear to turbid -- are visually distinguished, with classification accuracy exceeding 99% on a custom dataset. The system is configured to run autonomously, offering continuous assessment and visual alerts for deteriorating conditions. This visual protocol covers device assembly, system calibration, model deployment, and real-time monitoring demonstrations. The method supports sustainable aquaculture practices by enabling non-invasive, continuous evaluation of aquatic environments using affordable, scalable technologies. The approach can be adapted to other aquaculture or environmental monitoring contexts with minimal modification.
- 24 February 2026
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 228,p. e69744
Real-Time Pond Water Assessment via Embedded Deep Learning and Visual Data Acquisition: A Practical Monitoring Approach for Aquaculture
Maintaining optimal water quality is essential in aquaculture, particularly for ornamental species such as Kois, where color clarity and environmental balance are directly linked to health and aesthetics. This article presents a complete protocol for designing, deploying, and operating a real-time water quality monitoring system based on underwater image classification using embedded deep learning. The proposed system integrates a low-cost underwater camera with a Raspberry Pi-based controller network in an autonomous water surface robot, enabling the capture, transmission, and classification of aquatic images through a lightweight neural network model. Five water condition categories -- ranging from clear to turbid -- are visually distinguished, with classification accuracy exceeding 99% on a custom dataset. The system is configured to run autonomously, offering continuous assessment and visual alerts for deteriorating conditions. This visual protocol covers device assembly, system calibration, model deployment, and real-time monitoring demonstrations. The method supports sustainable aquaculture practices by enabling non-invasive, continuous evaluation of aquatic environments using affordable, scalable technologies. The approach can be adapted to other aquaculture or environmental monitoring contexts with minimal modification.
- 2 January 2026
- Published by Springer Nature
- p. 79-94
AIoT-Enabled Automated Cannabis Cultivation System with Integrated Disease Detection and Management
- 2 January 2026
- Published by Springer Nature
- p. 79-94
AIoT-Enabled Automated Cannabis Cultivation System with Integrated Disease Detection and Management
- 13 December 2025
- Published by MyJove Corporation
- No. 226,p. e69307
JoVE Video Dataset
Urbanization and rapid land-use change have intensified the urban heat island effect (UHIE), leading to elevated ambient temperatures, altered humidity, and increased accumulation of carbon dioxide (CO2) in dense urban environments. These microclimatic changes not only influence thermal comfort but also affect outdoor air quality and, consequently, indoor ventilation dynamics. Current monitoring approaches, such as satellite remote sensing and city-scale air quality stations, provide valuable insights but lack the façade-level spatial resolution necessary to inform building-level interventions. This study presents a reproducible, low-cost protocol for façade-specific monitoring of CO2, temperature, and humidity using non-dispersive infrared (NDIR)-based sensors integrated with microcontroller data loggers. Sensor modules are deployed on contrasting thermal zones-sun-exposed and shaded façades-to capture diurnal variations over a 24 h cycle. Calibration against outdoor baseline CO2 concentrations ensures measurement accuracy and comparability among sensors. The method was validated across four Indian cities with distinct urban forms. Results consistently revealed higher CO2 concentrations in densely built zones compared to adjacent green façades, with differences ranging from 19 ppm (Pune, India) to 78 ppm (Chennai, India). These gradients were further associated with localized temperature rises of up to 2 °C and reduced relative humidity, confirming the role of UHIE in exacerbating pollutant retention. The proposed protocol offers a scalable, field-friendly approach for urban microclimate assessment, HVAC optimization, and environmental health research. Beyond CO2, the methodology can be extended to capture additional air quality parameters such as PM₂.₅, PM₁₀, and VOCs, enabling a comprehensive assessment of urban air quality. By providing façade-level, real-time insights, this monitoring framework supports data-driven decision-making for sustainable building design, intelligent ventilation systems, and long-term climate-resilient urban planning.
- 13 December 2025
- Published by MyJove Corporation
- No. 226,p. e69307
JoVE Video Dataset
Urbanization and rapid land-use change have intensified the urban heat island effect (UHIE), leading to elevated ambient temperatures, altered humidity, and increased accumulation of carbon dioxide (CO2) in dense urban environments. These microclimatic changes not only influence thermal comfort but also affect outdoor air quality and, consequently, indoor ventilation dynamics. Current monitoring approaches, such as satellite remote sensing and city-scale air quality stations, provide valuable insights but lack the façade-level spatial resolution necessary to inform building-level interventions. This study presents a reproducible, low-cost protocol for façade-specific monitoring of CO2, temperature, and humidity using non-dispersive infrared (NDIR)-based sensors integrated with microcontroller data loggers. Sensor modules are deployed on contrasting thermal zones-sun-exposed and shaded façades-to capture diurnal variations over a 24 h cycle. Calibration against outdoor baseline CO2 concentrations ensures measurement accuracy and comparability among sensors. The method was validated across four Indian cities with distinct urban forms. Results consistently revealed higher CO2 concentrations in densely built zones compared to adjacent green façades, with differences ranging from 19 ppm (Pune, India) to 78 ppm (Chennai, India). These gradients were further associated with localized temperature rises of up to 2 °C and reduced relative humidity, confirming the role of UHIE in exacerbating pollutant retention. The proposed protocol offers a scalable, field-friendly approach for urban microclimate assessment, HVAC optimization, and environmental health research. Beyond CO2, the methodology can be extended to capture additional air quality parameters such as PM₂.₅, PM₁₀, and VOCs, enabling a comprehensive assessment of urban air quality. By providing façade-level, real-time insights, this monitoring framework supports data-driven decision-making for sustainable building design, intelligent ventilation systems, and long-term climate-resilient urban planning.
- 12 December 2025
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 226,p. e69307
Façade-Level Monitoring of CO2 Variability under Urban Heat Island Conditions using Low-Cost Sensor Data Loggers
Urbanization and rapid land-use change have intensified the urban heat island effect (UHIE), leading to elevated ambient temperatures, altered humidity, and increased accumulation of carbon dioxide (CO2) in dense urban environments. These microclimatic changes not only influence thermal comfort but also affect outdoor air quality and, consequently, indoor ventilation dynamics. Current monitoring approaches, such as satellite remote sensing and city-scale air quality stations, provide valuable insights but lack the façade-level spatial resolution necessary to inform building-level interventions. This study presents a reproducible, low-cost protocol for façade-specific monitoring of CO2, temperature, and humidity using non-dispersive infrared (NDIR)-based sensors integrated with microcontroller data loggers. Sensor modules are deployed on contrasting thermal zones-sun-exposed and shaded façades-to capture diurnal variations over a 24 h cycle. Calibration against outdoor baseline CO2 concentrations ensures measurement accuracy and comparability among sensors. The method was validated across four Indian cities with distinct urban forms. Results consistently revealed higher CO2 concentrations in densely built zones compared to adjacent green façades, with differences ranging from 19 ppm (Pune, India) to 78 ppm (Chennai, India). These gradients were further associated with localized temperature rises of up to 2 °C and reduced relative humidity, confirming the role of UHIE in exacerbating pollutant retention. The proposed protocol offers a scalable, field-friendly approach for urban microclimate assessment, HVAC optimization, and environmental health research. Beyond CO2, the methodology can be extended to capture additional air quality parameters such as PM₂.₅, PM₁₀, and VOCs, enabling a comprehensive assessment of urban air quality. By providing façade-level, real-time insights, this monitoring framework supports data-driven decision-making for sustainable building design, intelligent ventilation systems, and long-term climate-resilient urban planning.
- 12 December 2025
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 226,p. e69307
Façade-Level Monitoring of CO2 Variability under Urban Heat Island Conditions using Low-Cost Sensor Data Loggers
Urbanization and rapid land-use change have intensified the urban heat island effect (UHIE), leading to elevated ambient temperatures, altered humidity, and increased accumulation of carbon dioxide (CO2) in dense urban environments. These microclimatic changes not only influence thermal comfort but also affect outdoor air quality and, consequently, indoor ventilation dynamics. Current monitoring approaches, such as satellite remote sensing and city-scale air quality stations, provide valuable insights but lack the façade-level spatial resolution necessary to inform building-level interventions. This study presents a reproducible, low-cost protocol for façade-specific monitoring of CO2, temperature, and humidity using non-dispersive infrared (NDIR)-based sensors integrated with microcontroller data loggers. Sensor modules are deployed on contrasting thermal zones-sun-exposed and shaded façades-to capture diurnal variations over a 24 h cycle. Calibration against outdoor baseline CO2 concentrations ensures measurement accuracy and comparability among sensors. The method was validated across four Indian cities with distinct urban forms. Results consistently revealed higher CO2 concentrations in densely built zones compared to adjacent green façades, with differences ranging from 19 ppm (Pune, India) to 78 ppm (Chennai, India). These gradients were further associated with localized temperature rises of up to 2 °C and reduced relative humidity, confirming the role of UHIE in exacerbating pollutant retention. The proposed protocol offers a scalable, field-friendly approach for urban microclimate assessment, HVAC optimization, and environmental health research. Beyond CO2, the methodology can be extended to capture additional air quality parameters such as PM₂.₅, PM₁₀, and VOCs, enabling a comprehensive assessment of urban air quality. By providing façade-level, real-time insights, this monitoring framework supports data-driven decision-making for sustainable building design, intelligent ventilation systems, and long-term climate-resilient urban planning.
- Open Access
- 21 September 2024
- Published by Elsevier in Data in Brief
- Vol. 57, 110936
Facilitating spice recognition and classification: An image dataset of Indian spices
- 21 September 2024
- Published by Elsevier in Data in Brief
- Vol. 57, 110936
Open AccessFacilitating spice recognition and classification: An image dataset of Indian spices