  • Ex Vivo Validation of the TONOVET Plus and TONOVET Pro in Cynomolgus Monkeys ( Macaca fascicularis ): Comparison of Canine and Lapine Calibration Modes

    by Wontae Kim, Seonmi Kang, Jiwon Lee, Jun Young Lee, Kangmoon Seo

    Objective: To evaluate the accuracy of the TONOVET Plus (TVP) and TONOVET Pro (TVPR) in measuring intraocular pressure (IOP) in ex vivo cynomolgus monkey eyes compared to manometry, and to determine the accuracy of Canine and Lapine calibration modes: Animals Studied: Five enucleated eyes from three cynomolgus monkeys. Procedures: The anterior chambers were cannulated to regulate IOP manometrically from 5 to 80 mmHg. Agreement between tonometric and manometric readings was analyzed using a linear mixed‐effects model (LMM), Lin's concordance correlation coefficient (CCC), and repeated‐measures Bland–Altman analysis. Data points at the 80 mmHg manometric setting were excluded to prevent artificial distortion from the devices' maximum display limits. Results: Strong linear relationships were observed between manometric and tonometric IOPs for all modes. However, the Lapine mode demonstrated proportional overestimation with steeper regression slopes compared to the Canine mode. The Canine mode showed excellent agreement (CCC: 0.967 for TVP, 0.971 for TVPR) with minimal mean bias. In contrast, the Lapine mode exhibited significant positive bias and wider limits of agreement, particularly at higher pressures. Conclusions: Both TVP and TVPR provided accurate and reliable IOP measurements in cynomolgus monkeys when using the Canine calibration mode. Despite the central corneal thickness of cynomolgus monkeys being closer to that of rabbits, the Lapine mode resulted in significant overestimation and is not recommended. Among the tested settings, the Canine mode provided highly accurate IOP measurements with minimal bias, whereas the Lapine mode significantly overestimated IOP.


  • Open Access

    Validation of Recalibrated TONOVET Plus and TONOVET Pro in Canine Eyes Compared to Manometer and TONOVET

    by Jiwon Lee, Wontae Kim, Jaeho Shim, Yujin Kim, Seonmi Kang, Young‐Kyoung Yoo, Young‐Ho Lee, Kangmoon Seo

    Objective: To evaluate the accuracy of recalibrated TONOVET Plus (rTVP) and the newly released TONOVET Pro (TVPR) in measuring intraocular pressure (IOP) in ex vivo canine eyes compared to manometer and the established TONOVET (TV). Procedure: Sixteen enucleated canine eyes were cannulated to establish manometric IOPs ranging from 5 to 80 mmHg. IOP measurements were obtained using TV, rTVP, and TVPR. Results: All tonometers showed a strong correlation with the manometer ( R 2 > 0.98). Measurements from rTVP and TVPR exhibited almost perfect agreement with the manometer (CCC = 0.9974 for both), whereas TV demonstrated lower agreement (CCC = 0.9874) associated with greater systematic bias. Specifically, TV showed a lower proportional bias (95% confidence interval [CI] of the slope = 0.987–1.006) but a larger systematic bias (intercept = −3.33 mmHg) compared to rTVP and TVPR (95% CI of the slope = 1.045–1.066 and 1.045–1.063; intercept = −2.532 and −2.633 mmHg, respectively). In accuracy analyses by range, rTVP and TVPR showed no significant difference from the manometer in the 30–70 mmHg and 35–80 mmHg IOP ranges, respectively. Conclusions: Among the ICare rebound tonometers, rTVP and TVPR provided the most accurate IOP measurements in the ex vivo analysis and demonstrated particularly strong agreement in the high IOP range, suggesting their suitability for IOP measurement in glaucomatous patients.