Anna Lorenzin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anna Lorenzin has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Alessandra Brendolan
International Renal Research Institute of Vicenza, 36100 Vicenza, Italy
2 shared publications - Carlotta Caprara
UOC Nefrologia, Dialisi e Trapianto Renale AULSS 8 BERICA Ospedale San Bortolo Vicenza
2 shared publications - Claudia Benedetti
Department of Nephrology and Dialysis, San Bassiano Hospital, 36061 Bassano, Italy
2 shared publications - Claudio Ronco
International Renal Research Institute of Vicenza (IRRIV), Vicenza, Italy
2 shared publications - Marco Simonini
Nephrology and Dialysis Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy
2 shared publications - Monica Zanella
Department of Nephrology, Dialysis and Transplant, San Bortolo Hospital, 36100 Vicenza, Italy
2 shared publications
Latest Publications
- Open Access
- 7 March 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (6) , 1798
Assessment of Safety and Efficacy of Expanded Hemodialysis with Medium Cut-Off Dialyzer Compared to Haemodiafiltration
Background: Removal of large uraemic toxins is still a challenge. Haemodiafiltration (HDF) has produced some results, although large convective volume, optimal vascular access to increase the blood flow rate and strict water quality management are required. Medium cut-off, high-retention-onset membranes have been recently developed, introducing the concept therapy called expanded haemodialysis (HDx). Furthermore, vitamin E-coated membrane has potential beneficial effects on inflammation and oxidative stress. Methods: A prospective longitudinal multicentre study was conducted for 3 months among 24 chronic haemodialysis patients. Patients were randomly assigned into either HDF with high-flux membrane or HDx with Theranova or ViE-X membrane. The primary goal was to assess albumin loss among the three types of dialyzers. Secondary goals included assessment of depurative efficacy for uraemic toxins and clinical outcomes. Results: Mean albumin loss was significantly higher in patients undergoing HDx with Theranova membrane, without any difference in serum albumin concentration among the three groups. Instantaneous clearance of small and middle molecules was significantly higher in patients undergoing HDF, but we did not find differences in removal ratio and Kt/V. Reduction in the erythropoietin resistance index was observed in patients treated with ViE-X membrane due to their lower dialysis vintage. Conclusions: The higher albumin loss during HDx has no effects on pre-dialysis serum albumin. HDx with Theranova in the presence of lower session length, lower Qb, lower convective dose, and lower instantaneous clearance reached the same dialysis efficacy compared to HDF.
- 7 March 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (6) , 1798
Open AccessAssessment of Safety and Efficacy of Expanded Hemodialysis with Medium Cut-Off Dialyzer Compared to Haemodiafiltration
Background: Removal of large uraemic toxins is still a challenge. Haemodiafiltration (HDF) has produced some results, although large convective volume, optimal vascular access to increase the blood flow rate and strict water quality management are required. Medium cut-off, high-retention-onset membranes have been recently developed, introducing the concept therapy called expanded haemodialysis (HDx). Furthermore, vitamin E-coated membrane has potential beneficial effects on inflammation and oxidative stress. Methods: A prospective longitudinal multicentre study was conducted for 3 months among 24 chronic haemodialysis patients. Patients were randomly assigned into either HDF with high-flux membrane or HDx with Theranova or ViE-X membrane. The primary goal was to assess albumin loss among the three types of dialyzers. Secondary goals included assessment of depurative efficacy for uraemic toxins and clinical outcomes. Results: Mean albumin loss was significantly higher in patients undergoing HDx with Theranova membrane, without any difference in serum albumin concentration among the three groups. Instantaneous clearance of small and middle molecules was significantly higher in patients undergoing HDF, but we did not find differences in removal ratio and Kt/V. Reduction in the erythropoietin resistance index was observed in patients treated with ViE-X membrane due to their lower dialysis vintage. Conclusions: The higher albumin loss during HDx has no effects on pre-dialysis serum albumin. HDx with Theranova in the presence of lower session length, lower Qb, lower convective dose, and lower instantaneous clearance reached the same dialysis efficacy compared to HDF.
- Open Access
- 20 February 2025
- Published by MDPI AG in Preprints.org
Assessment of Safety and Efficacy of Expanded Hemodialysis with Medium Cut-Off Dialyzer Compared to Hemodiafiltration
Background: Removal of large uraemic toxins is still a challenge. HDF has produced some results although large convective volume, optimal vascular access to increase the blood flow rate and strict water quality management are required. Medium Cut-Off, high Retention Onset membrane have been recently developed introducing the concept therapy called “expanded haemodialysis” (HDx). Furthermore, vitamin E-coated membrane has potential beneficial effects on inflammation and oxidative stress. Ma-terial and Methods: A prospective longitudinal multi-center study was conducted for 3 months among 24 chronic haemodialysis patients. Patients were randomly assigned into either HDF with high flux membrane or HDx with Theranova or ViE-X mem-brane. The primary goal was to assess albumin loss among the three types of dialyzers. Secondary goals included assessment of depurative efficacy for uraemic toxins and clinical outcomes. Results: Mean albumin loss was significantly higher in patients undergoing HDx with Theranova membrane (ANOVA, p< 0.001) without any differ-ence in serum albumin concentration among the three groups. Instantaneous clearance of small and middle molecules was significantly higher in patients undergoing HDF, but we didn’t find differences in removal ratio and Kt/V. Reduction of Erythropoietin resistance index was observed in patients treated with ViE-X membrane due to their lower dialysis vintage. Conclusion: The higher albumin loss during HDx has no effects on pre-dialysis serum albumin. HDx with Theranova® in presence of lower session length, lower Qb , lower convective dose and lower instantaneous clearance reached same dialysis efficacy compared to HDF.
- 20 February 2025
- Published by MDPI AG in Preprints.org
Open AccessAssessment of Safety and Efficacy of Expanded Hemodialysis with Medium Cut-Off Dialyzer Compared to Hemodiafiltration
Background: Removal of large uraemic toxins is still a challenge. HDF has produced some results although large convective volume, optimal vascular access to increase the blood flow rate and strict water quality management are required. Medium Cut-Off, high Retention Onset membrane have been recently developed introducing the concept therapy called “expanded haemodialysis” (HDx). Furthermore, vitamin E-coated membrane has potential beneficial effects on inflammation and oxidative stress. Ma-terial and Methods: A prospective longitudinal multi-center study was conducted for 3 months among 24 chronic haemodialysis patients. Patients were randomly assigned into either HDF with high flux membrane or HDx with Theranova or ViE-X mem-brane. The primary goal was to assess albumin loss among the three types of dialyzers. Secondary goals included assessment of depurative efficacy for uraemic toxins and clinical outcomes. Results: Mean albumin loss was significantly higher in patients undergoing HDx with Theranova membrane (ANOVA, p< 0.001) without any differ-ence in serum albumin concentration among the three groups. Instantaneous clearance of small and middle molecules was significantly higher in patients undergoing HDF, but we didn’t find differences in removal ratio and Kt/V. Reduction of Erythropoietin resistance index was observed in patients treated with ViE-X membrane due to their lower dialysis vintage. Conclusion: The higher albumin loss during HDx has no effects on pre-dialysis serum albumin. HDx with Theranova® in presence of lower session length, lower Qb , lower convective dose and lower instantaneous clearance reached same dialysis efficacy compared to HDF.