Marina V. Kuleshova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marina V. Kuleshova has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Oleg V. Sapelnikov
FSBI «NMRC of cardiology named after academician E.I.Chazov» of the MH RF
4 shared publications - Tatiana M. Uskach
FSBI «NMRC of cardiology named after academician E.I.Chazov» of the MH RF
4 shared publications - Anna V. Vereshchagina
FSBI «NMRC of cardiology named after academician E.I.Chazov» of the MH RF
3 shared publications - Darin F. Ardus
FSBI «NMRC of cardiology named after academician E.I.Chazov» of the MH RF
3 shared publications - Valeriia A. Amanatova
FSBI «NMRC of cardiology named after academician E.I.Chazov» of the MH RF
3 shared publications А. В. Верещагина
ФГБУ "Национальный медицинский исследовательский центр кардиологии им. акад. Е.И. Чазова" Минздрава России
1 shared publication
Latest Publications
- Open Access
- 28 August 2026
- Published by Silicea - Poligraf, LLC in Cardiovascular Therapy and Prevention
- Vol. 25 (8) , 4800
Evaluation of multisensor data for diagnosing clinical deterioration in patients with heart failure and implantable cardioverter-defibrillators
Aim . To evaluate the potential of multisensor monitoring by an implantable cardioverter-defibrillator (ICD) for detecting clinical deterioration of heart failure (HF) by comparing sensor data with laboratory, functional, and clinical parameters. Material and methods . This prospective study included 56 patients with NYHA class II-III HF and a left ventricular ejection fraction ≤35% who were implanted with multisensor ICDs. Follow-up visits were conducted at 6 and 12 months, including the 6-minute walk test (6MWT), echocardiography, N-terminal pro-brain natriuretic peptide (NT-proBNP) level assessment, and device interrogation with sensor data analysis. Based on the 6-month visit results, patients were divided into groups with and without clinical HF deterioration. Deterioration criteria included at least one of the following: a decrease in 6MWT distance, edema worsening, or an increase in NT-proBNP levels by >30% from baseline, combined with a HeartLogic index exceeding the threshold >16. Correlation analysis was used to assess associations between selected multisensor monitoring parameters and clinical/laboratory indicators in the entire cohort. Additionally, an exploratory subgroup analysis was performed for patients with clinical HF deterioration. Results . Heart failure (HF) clinical worsening after 6 months was observed in 22 (39,3%) patients and was associated with unfavorable changes of multisensor parameters compared to patients without HF progression, an increase in NT-proBNP levels (2182 vs 847 pg/mL; pConclusion . Multisensor ICD monitoring is associated with clinical, laboratory, and functional signs of HF worsening. Unfavorable dynamics of individual device-detected parameters were accompanied by higher NT-proBNP levels, reduced 6MWT distance, and less favorable echocardiographic indices, which confirms the potential of multisensor monitoring for proactive and personalized patient management and warrants further investigation in larger prospective studies.
- 28 August 2026
- Published by Silicea - Poligraf, LLC in Cardiovascular Therapy and Prevention
- Vol. 25 (8) , 4800
Open AccessEvaluation of multisensor data for diagnosing clinical deterioration in patients with heart failure and implantable cardioverter-defibrillators
Aim . To evaluate the potential of multisensor monitoring by an implantable cardioverter-defibrillator (ICD) for detecting clinical deterioration of heart failure (HF) by comparing sensor data with laboratory, functional, and clinical parameters. Material and methods . This prospective study included 56 patients with NYHA class II-III HF and a left ventricular ejection fraction ≤35% who were implanted with multisensor ICDs. Follow-up visits were conducted at 6 and 12 months, including the 6-minute walk test (6MWT), echocardiography, N-terminal pro-brain natriuretic peptide (NT-proBNP) level assessment, and device interrogation with sensor data analysis. Based on the 6-month visit results, patients were divided into groups with and without clinical HF deterioration. Deterioration criteria included at least one of the following: a decrease in 6MWT distance, edema worsening, or an increase in NT-proBNP levels by >30% from baseline, combined with a HeartLogic index exceeding the threshold >16. Correlation analysis was used to assess associations between selected multisensor monitoring parameters and clinical/laboratory indicators in the entire cohort. Additionally, an exploratory subgroup analysis was performed for patients with clinical HF deterioration. Results . Heart failure (HF) clinical worsening after 6 months was observed in 22 (39,3%) patients and was associated with unfavorable changes of multisensor parameters compared to patients without HF progression, an increase in NT-proBNP levels (2182 vs 847 pg/mL; pConclusion . Multisensor ICD monitoring is associated with clinical, laboratory, and functional signs of HF worsening. Unfavorable dynamics of individual device-detected parameters were accompanied by higher NT-proBNP levels, reduced 6MWT distance, and less favorable echocardiographic indices, which confirms the potential of multisensor monitoring for proactive and personalized patient management and warrants further investigation in larger prospective studies.
- 28 May 2026
- Published by Intermedservice Ltd in Eurasian heart journal
- No. 2
The effect of correction of HF therapy based on indicators of multisensory ICD sensors on the clinical course of the disease and the frequency of shocks
Objective: to evaluate the effect of correction of HF therapy based on indicators of multisensory ICD sensors on the clinical course of the disease and the frequency of shocks. Materials and methods. 111 patients with HF and indications for ICD implantation for the primary prevention of sudden cardiac death were included in the prospective study, then they were divided into two groups: in the studied (n=56) ICD with a multisensory set of sensors; in the comparison group (n=55), standard ICD without sensors. The patients were monitored for 12 months, and the dynamics of quality of life, clinical and laboratory parameters, device monitoring data, discharge episodes, and the number of hospitalizations due to HF decompensation were analyzed. Results. The patient groups were initially comparable in terms of gender, age, etiology of the disease and severity of the condition. All patients were on optimal medication therapy for HF for more than 3 months. Initially, there were no significant differences in the level of NTpro-BNP and the six-minute walking test distance, and there were no еchocardiography indices in both groups. After 6 months, during device interrogation, diuretic therapy was changed in the study group, taking into account the indicators of multisensory sensors, in the comparison group only based on clinical data. After 12 months, both groups showed positive dynamics in the quality of life index; a significant increase in ejection fraction and NT-proBNP levels in the study group, a significant decrease in the six-minute walking test distance in the comparison group, a comparable number of both adequate and inadequate ICD discharges, and a significantly lower number of hospitalizations for decompensation in the study group. Conclusion. The use of ICD multisensory monitoring was associated with a statistically significant improvement in the clinical course of HF and the frequency of shocks in patients compared with standard ICD.
- 28 May 2026
- Published by Intermedservice Ltd in Eurasian heart journal
- No. 2
The effect of correction of HF therapy based on indicators of multisensory ICD sensors on the clinical course of the disease and the frequency of shocks
Objective: to evaluate the effect of correction of HF therapy based on indicators of multisensory ICD sensors on the clinical course of the disease and the frequency of shocks. Materials and methods. 111 patients with HF and indications for ICD implantation for the primary prevention of sudden cardiac death were included in the prospective study, then they were divided into two groups: in the studied (n=56) ICD with a multisensory set of sensors; in the comparison group (n=55), standard ICD without sensors. The patients were monitored for 12 months, and the dynamics of quality of life, clinical and laboratory parameters, device monitoring data, discharge episodes, and the number of hospitalizations due to HF decompensation were analyzed. Results. The patient groups were initially comparable in terms of gender, age, etiology of the disease and severity of the condition. All patients were on optimal medication therapy for HF for more than 3 months. Initially, there were no significant differences in the level of NTpro-BNP and the six-minute walking test distance, and there were no еchocardiography indices in both groups. After 6 months, during device interrogation, diuretic therapy was changed in the study group, taking into account the indicators of multisensory sensors, in the comparison group only based on clinical data. After 12 months, both groups showed positive dynamics in the quality of life index; a significant increase in ejection fraction and NT-proBNP levels in the study group, a significant decrease in the six-minute walking test distance in the comparison group, a comparable number of both adequate and inadequate ICD discharges, and a significantly lower number of hospitalizations for decompensation in the study group. Conclusion. The use of ICD multisensory monitoring was associated with a statistically significant improvement in the clinical course of HF and the frequency of shocks in patients compared with standard ICD.
- 25 December 2025
- Published by Media Sphere Publishing Group in Russian Cardiology Bulletin
- Vol. 20 (4) , 48-55
Monitoring of chronic heart failure using transthoracic impedance and heart rate variability sensor in patients with cardioverter defibrillator
Objective. To evaluate the role of transthoracic impedance (TTI) and heart rate variability (HRV) in control of HF deterioration in patients with implanted ICD. Material and methods. The study included 48 patients with HF class II-III, LVEF<35% and indications for primary prevention of SCD. They received optimal therapy of HF for more than three months. The patients were implanted with CHARISMA TM EL ICD Boston Scientific, and then they were followed-up for 6 months. We evaluated the indicators of TTI and HRV sensors during ICD intervention, the number of shocks, clinical and laboratory dynamics of HF and quality of life, as well as the need for diuretic therapy. Results. Mean age of patients was 56.4±13.6 years, male patients predominated. Coronary artery disease, dilated cardiomyopathy and hypertension were the main causes of HF. We identified patients (n=17) with clinical deterioration of HF defined as the presence of at least one of the following signs: increased HF class, decreased 6MWT distance and higher need for diuretic therapy. At ICD interrogation, this group demonstrated lower TTI and HRV values, higher NT-proBNP and decreased 6MWT distance. Conclusion. TTI and HRV in patients with CVD can serve as an accurate indicator for predicting and detecting deterioration of CHF.
- 25 December 2025
- Published by Media Sphere Publishing Group in Russian Cardiology Bulletin
- Vol. 20 (4) , 48-55
Monitoring of chronic heart failure using transthoracic impedance and heart rate variability sensor in patients with cardioverter defibrillator
Objective. To evaluate the role of transthoracic impedance (TTI) and heart rate variability (HRV) in control of HF deterioration in patients with implanted ICD. Material and methods. The study included 48 patients with HF class II-III, LVEF<35% and indications for primary prevention of SCD. They received optimal therapy of HF for more than three months. The patients were implanted with CHARISMA TM EL ICD Boston Scientific, and then they were followed-up for 6 months. We evaluated the indicators of TTI and HRV sensors during ICD intervention, the number of shocks, clinical and laboratory dynamics of HF and quality of life, as well as the need for diuretic therapy. Results. Mean age of patients was 56.4±13.6 years, male patients predominated. Coronary artery disease, dilated cardiomyopathy and hypertension were the main causes of HF. We identified patients (n=17) with clinical deterioration of HF defined as the presence of at least one of the following signs: increased HF class, decreased 6MWT distance and higher need for diuretic therapy. At ICD interrogation, this group demonstrated lower TTI and HRV values, higher NT-proBNP and decreased 6MWT distance. Conclusion. TTI and HRV in patients with CVD can serve as an accurate indicator for predicting and detecting deterioration of CHF.
- Open Access
- 20 February 2025
- Published by Consilium Medicum in Terapevticheskii arkhiv
- Vol. 97 (1) , 80-85
Sudden cardiac death and decompensation of heart failure: how to reduce the risks. A review
The main causes of death in patients with heart failure (HF) are sudden cardiac death and decompensation of HF, especially with a low left ventricular ejection fraction. The prediction and prevention of risk factors for the development of these conditions are important goals both for guideline-directed medical therapy and for electrophysiological treatment methods. The article presents an overview of clinical studies devoted to the study of implantable cardioverter defibrillators in the prevention of sudden cardiac death, highlights the issues of monitoring the course of HF. Special attention is paid to multisensory monitoring in implantable devices equipped with a unique set of sensors for early diagnosis of the development of HF decompensation. It is expected that the practical use of such devices will reduce the number of exacerbations and hospitalizations for HF by detecting signs of threatening decompensation of blood circulation before the appearance of active symptoms, and as a result will reduce mortality in this category of patients.
- 20 February 2025
- Published by Consilium Medicum in Terapevticheskii arkhiv
- Vol. 97 (1) , 80-85
Open AccessSudden cardiac death and decompensation of heart failure: how to reduce the risks. A review
The main causes of death in patients with heart failure (HF) are sudden cardiac death and decompensation of HF, especially with a low left ventricular ejection fraction. The prediction and prevention of risk factors for the development of these conditions are important goals both for guideline-directed medical therapy and for electrophysiological treatment methods. The article presents an overview of clinical studies devoted to the study of implantable cardioverter defibrillators in the prevention of sudden cardiac death, highlights the issues of monitoring the course of HF. Special attention is paid to multisensory monitoring in implantable devices equipped with a unique set of sensors for early diagnosis of the development of HF decompensation. It is expected that the practical use of such devices will reduce the number of exacerbations and hospitalizations for HF by detecting signs of threatening decompensation of blood circulation before the appearance of active symptoms, and as a result will reduce mortality in this category of patients.